Cargando…
Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis
OBJECTIVE: Methylene blue (MB) and spring microcoils are used for the preoperative localization of small pulmonary nodules (SPNs). We aimed to compare the efficacy and safety of these methods using published data. METHODS: We identified randomized controlled trials and observational studies that ass...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10387794/ https://www.ncbi.nlm.nih.gov/pubmed/37498225 http://dx.doi.org/10.1177/03000605231187938 |
_version_ | 1785081963775787008 |
---|---|
author | Wang, Mengchen Yu, Yikang Li, Lu Qian, Chenfeng |
author_facet | Wang, Mengchen Yu, Yikang Li, Lu Qian, Chenfeng |
author_sort | Wang, Mengchen |
collection | PubMed |
description | OBJECTIVE: Methylene blue (MB) and spring microcoils are used for the preoperative localization of small pulmonary nodules (SPNs). We aimed to compare the efficacy and safety of these methods using published data. METHODS: We identified randomized controlled trials and observational studies that assessed preoperative SPN localization using MB or spring microcoil and compared these using a meta-analysis. RESULTS: Seven studies of 933 patients were identified, in whom 1081 SPNs were located. Four hundred twenty-four SPNs were located using MB (n = 359 participants), and 657 SPNs were located using the spring microcoil method (n = 574 participants). The prevalence of technical success of SPN localization was higher using MB (mean deviation [MD]: 0.43; 95% confidence interval [CI]: 0.20, 0.93); the incidence of postoperative complications was lower (MD: 1.70; 95% CI: 1.09, 2.65); and the time taken for removal was longer (MD: −12.37; 95% CI: −22.60, −2.13). There were no differences with respect to the successful wedge resection rate, the time taken for localization, the duration of the procedure, or the mean hospital stay. CONCLUSIONS: Both methods can detect SPNs; however, MB is associated with a higher success rate and fewer postoperative complications, while spring microcoil localization is associated with more rapid removal. |
format | Online Article Text |
id | pubmed-10387794 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-103877942023-08-01 Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis Wang, Mengchen Yu, Yikang Li, Lu Qian, Chenfeng J Int Med Res Meta Analysis OBJECTIVE: Methylene blue (MB) and spring microcoils are used for the preoperative localization of small pulmonary nodules (SPNs). We aimed to compare the efficacy and safety of these methods using published data. METHODS: We identified randomized controlled trials and observational studies that assessed preoperative SPN localization using MB or spring microcoil and compared these using a meta-analysis. RESULTS: Seven studies of 933 patients were identified, in whom 1081 SPNs were located. Four hundred twenty-four SPNs were located using MB (n = 359 participants), and 657 SPNs were located using the spring microcoil method (n = 574 participants). The prevalence of technical success of SPN localization was higher using MB (mean deviation [MD]: 0.43; 95% confidence interval [CI]: 0.20, 0.93); the incidence of postoperative complications was lower (MD: 1.70; 95% CI: 1.09, 2.65); and the time taken for removal was longer (MD: −12.37; 95% CI: −22.60, −2.13). There were no differences with respect to the successful wedge resection rate, the time taken for localization, the duration of the procedure, or the mean hospital stay. CONCLUSIONS: Both methods can detect SPNs; however, MB is associated with a higher success rate and fewer postoperative complications, while spring microcoil localization is associated with more rapid removal. SAGE Publications 2023-07-27 /pmc/articles/PMC10387794/ /pubmed/37498225 http://dx.doi.org/10.1177/03000605231187938 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Meta Analysis Wang, Mengchen Yu, Yikang Li, Lu Qian, Chenfeng Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis |
title | Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis |
title_full | Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis |
title_fullStr | Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis |
title_full_unstemmed | Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis |
title_short | Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis |
title_sort | use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under ct guidance: a meta-analysis |
topic | Meta Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10387794/ https://www.ncbi.nlm.nih.gov/pubmed/37498225 http://dx.doi.org/10.1177/03000605231187938 |
work_keys_str_mv | AT wangmengchen useofmethyleneblueandaspringmicrocoilinthepreoperativelocalizationofsmallpulmonarynodulesunderctguidanceametaanalysis AT yuyikang useofmethyleneblueandaspringmicrocoilinthepreoperativelocalizationofsmallpulmonarynodulesunderctguidanceametaanalysis AT lilu useofmethyleneblueandaspringmicrocoilinthepreoperativelocalizationofsmallpulmonarynodulesunderctguidanceametaanalysis AT qianchenfeng useofmethyleneblueandaspringmicrocoilinthepreoperativelocalizationofsmallpulmonarynodulesunderctguidanceametaanalysis |