Cargando…

Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis

OBJECTIVE: Methylene blue (MB) and spring microcoils are used for the preoperative localization of small pulmonary nodules (SPNs). We aimed to compare the efficacy and safety of these methods using published data. METHODS: We identified randomized controlled trials and observational studies that ass...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Mengchen, Yu, Yikang, Li, Lu, Qian, Chenfeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10387794/
https://www.ncbi.nlm.nih.gov/pubmed/37498225
http://dx.doi.org/10.1177/03000605231187938
_version_ 1785081963775787008
author Wang, Mengchen
Yu, Yikang
Li, Lu
Qian, Chenfeng
author_facet Wang, Mengchen
Yu, Yikang
Li, Lu
Qian, Chenfeng
author_sort Wang, Mengchen
collection PubMed
description OBJECTIVE: Methylene blue (MB) and spring microcoils are used for the preoperative localization of small pulmonary nodules (SPNs). We aimed to compare the efficacy and safety of these methods using published data. METHODS: We identified randomized controlled trials and observational studies that assessed preoperative SPN localization using MB or spring microcoil and compared these using a meta-analysis. RESULTS: Seven studies of 933 patients were identified, in whom 1081 SPNs were located. Four hundred twenty-four SPNs were located using MB (n = 359 participants), and 657 SPNs were located using the spring microcoil method (n = 574 participants). The prevalence of technical success of SPN localization was higher using MB (mean deviation [MD]: 0.43; 95% confidence interval [CI]: 0.20, 0.93); the incidence of postoperative complications was lower (MD: 1.70; 95% CI: 1.09, 2.65); and the time taken for removal was longer (MD: −12.37; 95% CI: −22.60, −2.13). There were no differences with respect to the successful wedge resection rate, the time taken for localization, the duration of the procedure, or the mean hospital stay. CONCLUSIONS: Both methods can detect SPNs; however, MB is associated with a higher success rate and fewer postoperative complications, while spring microcoil localization is associated with more rapid removal.
format Online
Article
Text
id pubmed-10387794
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-103877942023-08-01 Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis Wang, Mengchen Yu, Yikang Li, Lu Qian, Chenfeng J Int Med Res Meta Analysis OBJECTIVE: Methylene blue (MB) and spring microcoils are used for the preoperative localization of small pulmonary nodules (SPNs). We aimed to compare the efficacy and safety of these methods using published data. METHODS: We identified randomized controlled trials and observational studies that assessed preoperative SPN localization using MB or spring microcoil and compared these using a meta-analysis. RESULTS: Seven studies of 933 patients were identified, in whom 1081 SPNs were located. Four hundred twenty-four SPNs were located using MB (n = 359 participants), and 657 SPNs were located using the spring microcoil method (n = 574 participants). The prevalence of technical success of SPN localization was higher using MB (mean deviation [MD]: 0.43; 95% confidence interval [CI]: 0.20, 0.93); the incidence of postoperative complications was lower (MD: 1.70; 95% CI: 1.09, 2.65); and the time taken for removal was longer (MD: −12.37; 95% CI: −22.60, −2.13). There were no differences with respect to the successful wedge resection rate, the time taken for localization, the duration of the procedure, or the mean hospital stay. CONCLUSIONS: Both methods can detect SPNs; however, MB is associated with a higher success rate and fewer postoperative complications, while spring microcoil localization is associated with more rapid removal. SAGE Publications 2023-07-27 /pmc/articles/PMC10387794/ /pubmed/37498225 http://dx.doi.org/10.1177/03000605231187938 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Meta Analysis
Wang, Mengchen
Yu, Yikang
Li, Lu
Qian, Chenfeng
Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis
title Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis
title_full Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis
title_fullStr Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis
title_full_unstemmed Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis
title_short Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis
title_sort use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under ct guidance: a meta-analysis
topic Meta Analysis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10387794/
https://www.ncbi.nlm.nih.gov/pubmed/37498225
http://dx.doi.org/10.1177/03000605231187938
work_keys_str_mv AT wangmengchen useofmethyleneblueandaspringmicrocoilinthepreoperativelocalizationofsmallpulmonarynodulesunderctguidanceametaanalysis
AT yuyikang useofmethyleneblueandaspringmicrocoilinthepreoperativelocalizationofsmallpulmonarynodulesunderctguidanceametaanalysis
AT lilu useofmethyleneblueandaspringmicrocoilinthepreoperativelocalizationofsmallpulmonarynodulesunderctguidanceametaanalysis
AT qianchenfeng useofmethyleneblueandaspringmicrocoilinthepreoperativelocalizationofsmallpulmonarynodulesunderctguidanceametaanalysis