Cargando…

Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm

Today, the elderly population is increasing, and there are many drawbacks for them, especially defects in their knee joints which lead to improper gait. To solve this problem, their knee joint can be replaced with knee arthroplasty. In this letter, level of improvement in the human gait before and a...

Descripción completa

Detalles Bibliográficos
Autores principales: Abbasi‐Kesbi, Reza, Fathi, Mohammad, Najafi, Mohammad, Nikfarjam, Alireza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10388232/
https://www.ncbi.nlm.nih.gov/pubmed/37529411
http://dx.doi.org/10.1049/htl2.12047
_version_ 1785082067443253248
author Abbasi‐Kesbi, Reza
Fathi, Mohammad
Najafi, Mohammad
Nikfarjam, Alireza
author_facet Abbasi‐Kesbi, Reza
Fathi, Mohammad
Najafi, Mohammad
Nikfarjam, Alireza
author_sort Abbasi‐Kesbi, Reza
collection PubMed
description Today, the elderly population is increasing, and there are many drawbacks for them, especially defects in their knee joints which lead to improper gait. To solve this problem, their knee joint can be replaced with knee arthroplasty. In this letter, level of improvement in the human gait before and after total knee arthroplasty (TKA) surgery is investigated using the dynamic time warping (DTW) algorithm. For this purpose, several volunteers who have problems with their knees are incorporated in a test before and after TKA surgery. Then, the data of gait analysis is collected and the data is compared with a reference using the DTW algorithm. The outcome results illustrate an improvement of 89%–97% by the proposed algorithm after TKA surgery. Therefore, patients can see improvement with high accuracy and very fast that result in more use this technique in TKR surgery.
format Online
Article
Text
id pubmed-10388232
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-103882322023-08-01 Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm Abbasi‐Kesbi, Reza Fathi, Mohammad Najafi, Mohammad Nikfarjam, Alireza Healthc Technol Lett Letters Today, the elderly population is increasing, and there are many drawbacks for them, especially defects in their knee joints which lead to improper gait. To solve this problem, their knee joint can be replaced with knee arthroplasty. In this letter, level of improvement in the human gait before and after total knee arthroplasty (TKA) surgery is investigated using the dynamic time warping (DTW) algorithm. For this purpose, several volunteers who have problems with their knees are incorporated in a test before and after TKA surgery. Then, the data of gait analysis is collected and the data is compared with a reference using the DTW algorithm. The outcome results illustrate an improvement of 89%–97% by the proposed algorithm after TKA surgery. Therefore, patients can see improvement with high accuracy and very fast that result in more use this technique in TKR surgery. John Wiley and Sons Inc. 2023-06-13 /pmc/articles/PMC10388232/ /pubmed/37529411 http://dx.doi.org/10.1049/htl2.12047 Text en © 2023 The Authors. Healthcare Technology Letters published by John Wiley & Sons Ltd on behalf of The Institution of Engineering and Technology. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Letters
Abbasi‐Kesbi, Reza
Fathi, Mohammad
Najafi, Mohammad
Nikfarjam, Alireza
Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm
title Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm
title_full Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm
title_fullStr Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm
title_full_unstemmed Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm
title_short Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm
title_sort assessment of human gait after total knee arthroplasty by dynamic time warping algorithm
topic Letters
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10388232/
https://www.ncbi.nlm.nih.gov/pubmed/37529411
http://dx.doi.org/10.1049/htl2.12047
work_keys_str_mv AT abbasikesbireza assessmentofhumangaitaftertotalkneearthroplastybydynamictimewarpingalgorithm
AT fathimohammad assessmentofhumangaitaftertotalkneearthroplastybydynamictimewarpingalgorithm
AT najafimohammad assessmentofhumangaitaftertotalkneearthroplastybydynamictimewarpingalgorithm
AT nikfarjamalireza assessmentofhumangaitaftertotalkneearthroplastybydynamictimewarpingalgorithm