Cargando…
Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm
Today, the elderly population is increasing, and there are many drawbacks for them, especially defects in their knee joints which lead to improper gait. To solve this problem, their knee joint can be replaced with knee arthroplasty. In this letter, level of improvement in the human gait before and a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10388232/ https://www.ncbi.nlm.nih.gov/pubmed/37529411 http://dx.doi.org/10.1049/htl2.12047 |
_version_ | 1785082067443253248 |
---|---|
author | Abbasi‐Kesbi, Reza Fathi, Mohammad Najafi, Mohammad Nikfarjam, Alireza |
author_facet | Abbasi‐Kesbi, Reza Fathi, Mohammad Najafi, Mohammad Nikfarjam, Alireza |
author_sort | Abbasi‐Kesbi, Reza |
collection | PubMed |
description | Today, the elderly population is increasing, and there are many drawbacks for them, especially defects in their knee joints which lead to improper gait. To solve this problem, their knee joint can be replaced with knee arthroplasty. In this letter, level of improvement in the human gait before and after total knee arthroplasty (TKA) surgery is investigated using the dynamic time warping (DTW) algorithm. For this purpose, several volunteers who have problems with their knees are incorporated in a test before and after TKA surgery. Then, the data of gait analysis is collected and the data is compared with a reference using the DTW algorithm. The outcome results illustrate an improvement of 89%–97% by the proposed algorithm after TKA surgery. Therefore, patients can see improvement with high accuracy and very fast that result in more use this technique in TKR surgery. |
format | Online Article Text |
id | pubmed-10388232 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-103882322023-08-01 Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm Abbasi‐Kesbi, Reza Fathi, Mohammad Najafi, Mohammad Nikfarjam, Alireza Healthc Technol Lett Letters Today, the elderly population is increasing, and there are many drawbacks for them, especially defects in their knee joints which lead to improper gait. To solve this problem, their knee joint can be replaced with knee arthroplasty. In this letter, level of improvement in the human gait before and after total knee arthroplasty (TKA) surgery is investigated using the dynamic time warping (DTW) algorithm. For this purpose, several volunteers who have problems with their knees are incorporated in a test before and after TKA surgery. Then, the data of gait analysis is collected and the data is compared with a reference using the DTW algorithm. The outcome results illustrate an improvement of 89%–97% by the proposed algorithm after TKA surgery. Therefore, patients can see improvement with high accuracy and very fast that result in more use this technique in TKR surgery. John Wiley and Sons Inc. 2023-06-13 /pmc/articles/PMC10388232/ /pubmed/37529411 http://dx.doi.org/10.1049/htl2.12047 Text en © 2023 The Authors. Healthcare Technology Letters published by John Wiley & Sons Ltd on behalf of The Institution of Engineering and Technology. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Letters Abbasi‐Kesbi, Reza Fathi, Mohammad Najafi, Mohammad Nikfarjam, Alireza Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm |
title | Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm |
title_full | Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm |
title_fullStr | Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm |
title_full_unstemmed | Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm |
title_short | Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm |
title_sort | assessment of human gait after total knee arthroplasty by dynamic time warping algorithm |
topic | Letters |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10388232/ https://www.ncbi.nlm.nih.gov/pubmed/37529411 http://dx.doi.org/10.1049/htl2.12047 |
work_keys_str_mv | AT abbasikesbireza assessmentofhumangaitaftertotalkneearthroplastybydynamictimewarpingalgorithm AT fathimohammad assessmentofhumangaitaftertotalkneearthroplastybydynamictimewarpingalgorithm AT najafimohammad assessmentofhumangaitaftertotalkneearthroplastybydynamictimewarpingalgorithm AT nikfarjamalireza assessmentofhumangaitaftertotalkneearthroplastybydynamictimewarpingalgorithm |