Cargando…
Comparison of outcomes of self-expanding versus balloon-expandable valves for transcatheter aortic valve replacement: a meta-analysis of randomized and propensity-matched studies
BACKGROUND: The postoperative outcomes of transcatheter aortic valve replacement (TAVR) with the new generation of self-expanding valves (SEV) and balloon-expandable valves (BEV) remain uncertain. METHODS: We conducted a meta-analysis based on randomized controlled trials (RCTs) and propensity score...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10388567/ https://www.ncbi.nlm.nih.gov/pubmed/37525092 http://dx.doi.org/10.1186/s12872-023-03397-3 |
Sumario: | BACKGROUND: The postoperative outcomes of transcatheter aortic valve replacement (TAVR) with the new generation of self-expanding valves (SEV) and balloon-expandable valves (BEV) remain uncertain. METHODS: We conducted a meta-analysis based on randomized controlled trials (RCTs) and propensity score-matched (PSM) studies to evaluate the performance of the new generation TAVR devices, with a focus on Edwards SAPIEN 3/Ultra BEV, Medtronic Evolut R/PRO SEV, and Boston ACURATE neo SEV. Our primary endpoints were mortality and complications at both 30 days and one year post-operation. RESULTS: A total of 4 RCTs and 14 PSM studies were included. Our findings showed no significant difference between SEV and BEV regarding 30-day and 1-year mortality rates. ACURATE SEV required less permanent pacemaker implantation (PPI) at 30-day as compared to SAPIEN BEV, while Evolut SEV required a higher rate of PPI than SAPIEN BEV. The incidence of stroke, major or life-threatening bleeding (MLTB), major vascular complications (MVC), coronary artery obstruction (CAO) and acute kidney injury (AKI) did not differ significantly between the two groups. SEV had a larger effective orifice area (EOA) and lower mean transvalvular gradients (MPG) compared to BEV. However, there was an increased risk of paravalvular leakage (PVL) associated with SEV. CONCLUSIONS: In terms of 30-day mortality, stroke, bleeding, MVC, AKI, CAO, and one-year mortality, there was comparability between the two valve types following TAVR. SEV was associated with better hemodynamic outcomes, except for a higher incidence of PVL. Compared to SAPIEN BEV, ACURATE SEV had a lower risk of PPI at 30 days, while Evolut SEV was associated with a higher risk of PPI. These findings underscore the importance of personalized valve selection. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-023-03397-3. |
---|