Cargando…
A comparative study of different methods for the determination of cadmium in various tissues of ramie (Boehmeria nivea L.)
Remediation of cadmium (Cd) pollution is one of the priorities of global environmental governance and accurate detection of Cd content is a key link in remediation of Cd pollution. This study aimed to compare three methods (inductively coupled plasma optical emission spectrometry (ICP-OES), inductiv...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10390602/ https://www.ncbi.nlm.nih.gov/pubmed/37522949 http://dx.doi.org/10.1007/s10661-023-11601-2 |
_version_ | 1785082513207590912 |
---|---|
author | Chen, Kunmei Mou, Pan Zhu, Aiguo Chen, Ping Chen, Jikang Gao, Gang Wang, Xiaofei Feng, Xinkang Yu, Chunming |
author_facet | Chen, Kunmei Mou, Pan Zhu, Aiguo Chen, Ping Chen, Jikang Gao, Gang Wang, Xiaofei Feng, Xinkang Yu, Chunming |
author_sort | Chen, Kunmei |
collection | PubMed |
description | Remediation of cadmium (Cd) pollution is one of the priorities of global environmental governance and accurate detection of Cd content is a key link in remediation of Cd pollution. This study aimed to compare three methods (inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), and graphite furnace-atomic absorption spectrometry (GF-AAS)) for the determination of Cd with different tissues of various ramie varieties, and distinguish the advantage and disadvantage of each method. In total, 162 samples of ramie (Boehmeria nivea L.), which is an ideal plant for heavy metal remediation, were detected and the results showed that the three methods were all suitable for the de-termination of Cd content in ramie. ICP-OES and ICP-MS were simpler, faster, and more sensitive than GF-AAS. ICP-MS could be recommended for the determination of samples with various concentrations of Cd. ICP-OES could be used for measurement of samples with > 100 mg/kg Cd content, while GF-AAS was suitable for the detection of samples with very high (> 550 mg/kg) or very low (< 10 mg/kg) Cd content. Overall, considering the accuracy, stability, and the cost of measurement, ICP-MS was the most suitable method for determination of Cd content. This study provides significant reference information for the research in the field of Cd pollution remediation. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10661-023-11601-2. |
format | Online Article Text |
id | pubmed-10390602 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-103906022023-08-02 A comparative study of different methods for the determination of cadmium in various tissues of ramie (Boehmeria nivea L.) Chen, Kunmei Mou, Pan Zhu, Aiguo Chen, Ping Chen, Jikang Gao, Gang Wang, Xiaofei Feng, Xinkang Yu, Chunming Environ Monit Assess Research Remediation of cadmium (Cd) pollution is one of the priorities of global environmental governance and accurate detection of Cd content is a key link in remediation of Cd pollution. This study aimed to compare three methods (inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), and graphite furnace-atomic absorption spectrometry (GF-AAS)) for the determination of Cd with different tissues of various ramie varieties, and distinguish the advantage and disadvantage of each method. In total, 162 samples of ramie (Boehmeria nivea L.), which is an ideal plant for heavy metal remediation, were detected and the results showed that the three methods were all suitable for the de-termination of Cd content in ramie. ICP-OES and ICP-MS were simpler, faster, and more sensitive than GF-AAS. ICP-MS could be recommended for the determination of samples with various concentrations of Cd. ICP-OES could be used for measurement of samples with > 100 mg/kg Cd content, while GF-AAS was suitable for the detection of samples with very high (> 550 mg/kg) or very low (< 10 mg/kg) Cd content. Overall, considering the accuracy, stability, and the cost of measurement, ICP-MS was the most suitable method for determination of Cd content. This study provides significant reference information for the research in the field of Cd pollution remediation. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10661-023-11601-2. Springer International Publishing 2023-07-31 2023 /pmc/articles/PMC10390602/ /pubmed/37522949 http://dx.doi.org/10.1007/s10661-023-11601-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Chen, Kunmei Mou, Pan Zhu, Aiguo Chen, Ping Chen, Jikang Gao, Gang Wang, Xiaofei Feng, Xinkang Yu, Chunming A comparative study of different methods for the determination of cadmium in various tissues of ramie (Boehmeria nivea L.) |
title | A comparative study of different methods for the determination of cadmium in various tissues of ramie (Boehmeria nivea L.) |
title_full | A comparative study of different methods for the determination of cadmium in various tissues of ramie (Boehmeria nivea L.) |
title_fullStr | A comparative study of different methods for the determination of cadmium in various tissues of ramie (Boehmeria nivea L.) |
title_full_unstemmed | A comparative study of different methods for the determination of cadmium in various tissues of ramie (Boehmeria nivea L.) |
title_short | A comparative study of different methods for the determination of cadmium in various tissues of ramie (Boehmeria nivea L.) |
title_sort | comparative study of different methods for the determination of cadmium in various tissues of ramie (boehmeria nivea l.) |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10390602/ https://www.ncbi.nlm.nih.gov/pubmed/37522949 http://dx.doi.org/10.1007/s10661-023-11601-2 |
work_keys_str_mv | AT chenkunmei acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT moupan acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT zhuaiguo acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT chenping acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT chenjikang acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT gaogang acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT wangxiaofei acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT fengxinkang acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT yuchunming acomparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT chenkunmei comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT moupan comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT zhuaiguo comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT chenping comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT chenjikang comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT gaogang comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT wangxiaofei comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT fengxinkang comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal AT yuchunming comparativestudyofdifferentmethodsforthedeterminationofcadmiuminvarioustissuesoframieboehmerianiveal |