Cargando…

Hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting

Off-pump coronary surgery requires mechanical cardiac displacement, which results in bi-ventricular systolic and diastolic dysfunction. Although transient, subsequent hemodynamic deterioration can be associated with poor prognosis and, in extreme cases, emergency conversion to on-pump surgery, which...

Descripción completa

Detalles Bibliográficos
Autores principales: Shim, Jae-Kwang, Kim, Kwang-Sub, Couture, Pierre, Denault, André, Kwak, Young-Lan, Yoo, Kyung-Jong, Youn, Young-Nam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Anesthesiologists 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10391074/
https://www.ncbi.nlm.nih.gov/pubmed/36824043
http://dx.doi.org/10.4097/kja.23103
_version_ 1785082619828895744
author Shim, Jae-Kwang
Kim, Kwang-Sub
Couture, Pierre
Denault, André
Kwak, Young-Lan
Yoo, Kyung-Jong
Youn, Young-Nam
author_facet Shim, Jae-Kwang
Kim, Kwang-Sub
Couture, Pierre
Denault, André
Kwak, Young-Lan
Yoo, Kyung-Jong
Youn, Young-Nam
author_sort Shim, Jae-Kwang
collection PubMed
description Off-pump coronary surgery requires mechanical cardiac displacement, which results in bi-ventricular systolic and diastolic dysfunction. Although transient, subsequent hemodynamic deterioration can be associated with poor prognosis and, in extreme cases, emergency conversion to on-pump surgery, which is associated with high morbidity and mortality. Thus, appropriate decision-making regarding whether the surgery can be proceeded based on objective hemodynamic targets is essential before coronary arteriotomy. For adequate hemodynamic management, avoiding myocardial oxygen supply-demand imbalance, which includes maintaining mean arterial pressure above 70 mmHg and preventing an increase in oxygen demand beyond the patient’s coronary reserve, must be prioritized. Maintaining mixed venous oxygen saturation above 60%, which reflects the lower limit of adequate global oxygen supply-demand balance, is also essential. Above all, severe mechanical cardiac displacement incurring compressive syndromes, which cannot be overcome by adjusting major determinants of cardiac output, should be avoided. An uncompromising form of cardiac constraint can be ruled out as long as the central venous pressure is not equal to or greater than the pulmonary artery diastolic (or occlusion) pressure, as this would reflect tamponade physiology. In addition, transesophageal echocardiography should be conducted to rule out mechanical cardiac displacement-induced ventricular interdependence, dyskinesia, severe mitral regurgitation, and left ventricular outflow tract obstruction with or without systolic motion of the anterior leaflet of the mitral valve, which cannot be tolerated during grafting. Finally, the ascending aorta should be carefully inspected for gas bubbles to prevent hemodynamic collapse caused by a massive gas embolism obstructing the right coronary ostium.
format Online
Article
Text
id pubmed-10391074
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-103910742023-08-02 Hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting Shim, Jae-Kwang Kim, Kwang-Sub Couture, Pierre Denault, André Kwak, Young-Lan Yoo, Kyung-Jong Youn, Young-Nam Korean J Anesthesiol Review Article Off-pump coronary surgery requires mechanical cardiac displacement, which results in bi-ventricular systolic and diastolic dysfunction. Although transient, subsequent hemodynamic deterioration can be associated with poor prognosis and, in extreme cases, emergency conversion to on-pump surgery, which is associated with high morbidity and mortality. Thus, appropriate decision-making regarding whether the surgery can be proceeded based on objective hemodynamic targets is essential before coronary arteriotomy. For adequate hemodynamic management, avoiding myocardial oxygen supply-demand imbalance, which includes maintaining mean arterial pressure above 70 mmHg and preventing an increase in oxygen demand beyond the patient’s coronary reserve, must be prioritized. Maintaining mixed venous oxygen saturation above 60%, which reflects the lower limit of adequate global oxygen supply-demand balance, is also essential. Above all, severe mechanical cardiac displacement incurring compressive syndromes, which cannot be overcome by adjusting major determinants of cardiac output, should be avoided. An uncompromising form of cardiac constraint can be ruled out as long as the central venous pressure is not equal to or greater than the pulmonary artery diastolic (or occlusion) pressure, as this would reflect tamponade physiology. In addition, transesophageal echocardiography should be conducted to rule out mechanical cardiac displacement-induced ventricular interdependence, dyskinesia, severe mitral regurgitation, and left ventricular outflow tract obstruction with or without systolic motion of the anterior leaflet of the mitral valve, which cannot be tolerated during grafting. Finally, the ascending aorta should be carefully inspected for gas bubbles to prevent hemodynamic collapse caused by a massive gas embolism obstructing the right coronary ostium. Korean Society of Anesthesiologists 2023-08 2023-02-24 /pmc/articles/PMC10391074/ /pubmed/36824043 http://dx.doi.org/10.4097/kja.23103 Text en Copyright © The Korean Society of Anesthesiologists, 2023 https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Shim, Jae-Kwang
Kim, Kwang-Sub
Couture, Pierre
Denault, André
Kwak, Young-Lan
Yoo, Kyung-Jong
Youn, Young-Nam
Hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting
title Hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting
title_full Hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting
title_fullStr Hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting
title_full_unstemmed Hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting
title_short Hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting
title_sort hemodynamic management during off-pump coronary artery bypass surgery: a narrative review of proper targets for safe execution and troubleshooting
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10391074/
https://www.ncbi.nlm.nih.gov/pubmed/36824043
http://dx.doi.org/10.4097/kja.23103
work_keys_str_mv AT shimjaekwang hemodynamicmanagementduringoffpumpcoronaryarterybypasssurgeryanarrativereviewofpropertargetsforsafeexecutionandtroubleshooting
AT kimkwangsub hemodynamicmanagementduringoffpumpcoronaryarterybypasssurgeryanarrativereviewofpropertargetsforsafeexecutionandtroubleshooting
AT couturepierre hemodynamicmanagementduringoffpumpcoronaryarterybypasssurgeryanarrativereviewofpropertargetsforsafeexecutionandtroubleshooting
AT denaultandre hemodynamicmanagementduringoffpumpcoronaryarterybypasssurgeryanarrativereviewofpropertargetsforsafeexecutionandtroubleshooting
AT kwakyounglan hemodynamicmanagementduringoffpumpcoronaryarterybypasssurgeryanarrativereviewofpropertargetsforsafeexecutionandtroubleshooting
AT yookyungjong hemodynamicmanagementduringoffpumpcoronaryarterybypasssurgeryanarrativereviewofpropertargetsforsafeexecutionandtroubleshooting
AT younyoungnam hemodynamicmanagementduringoffpumpcoronaryarterybypasssurgeryanarrativereviewofpropertargetsforsafeexecutionandtroubleshooting