Cargando…
Higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: A 2-year follow-up
PURPOSE: To evaluate the postoperative visual outcomes, that is, corneal higher-order aberrations (HOAs) and visual quality, of patients with an angle kappa greater than 0.30 mm who underwent angle kappa adjustment during small-incision lenticule extraction (SMILE) 2 years after surgery compared to...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10391436/ https://www.ncbi.nlm.nih.gov/pubmed/37203043 http://dx.doi.org/10.4103/IJO.IJO_3017_22 |
_version_ | 1785082707088244736 |
---|---|
author | Xie, Mengzhen Deng, Yingping Sun, Chengshu Qiu, Lemei Tang, Jing |
author_facet | Xie, Mengzhen Deng, Yingping Sun, Chengshu Qiu, Lemei Tang, Jing |
author_sort | Xie, Mengzhen |
collection | PubMed |
description | PURPOSE: To evaluate the postoperative visual outcomes, that is, corneal higher-order aberrations (HOAs) and visual quality, of patients with an angle kappa greater than 0.30 mm who underwent angle kappa adjustment during small-incision lenticule extraction (SMILE) 2 years after surgery compared to eyes with an angle kappa less than 0.30 mm. METHODS: This was a retrospective study and included 12 patients from October 2019 to December 2019 who underwent the SMILE procedure for correction of myopia and myopic astigmatism and had one eye with a large kappa angle and another eye with a small kappa angle. Twenty-four months after surgery, an optical quality analysis system (OQAS II; Visiometrics, Terrassa, Spain) was used to measure the modulation transfer function cutoff frequency (MTF(cutoff)), Strehl2D ratio, and objective scatter index (OSI). HOAs were measured with a Tracey iTrace Visual Function Analyzer (Tracey version 6.1.0; Tracey Technologies, Houston, TX, USA). Assessment of subjective visual quality was achieved using the quality of vision (QOV) questionnaire. RESULTS: At 24 months postoperatively, the mean spherical equivalent (SE) refraction was − 0.32 ± 0.40 and − 0.31 ± 0.35 in the S-kappa group (kappa <0.3 mm) and the L-kappa group (kappa ≥0.3 mm), respectively (P > 0.05). The mean OSI was 0.73 ± 0.32 and 0.81 ± 0.47, respectively (P > 0.05). There was no significant difference in MTF(cutoff) and Strehl2D ratio between the two groups (P > 0.05). Total HOA, coma, spherical, trefoil, and secondary astigmatism were not significantly different (P > 0.05) between the two groups. CONCLUSION: Adjustment of angle kappa during SMILE helps reduce the decentration, results in less HOAs, and promotes visual quality. It provides a reliable method to optimize the treatment concentration in SMILE. |
format | Online Article Text |
id | pubmed-10391436 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-103914362023-08-02 Higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: A 2-year follow-up Xie, Mengzhen Deng, Yingping Sun, Chengshu Qiu, Lemei Tang, Jing Indian J Ophthalmol Original Article PURPOSE: To evaluate the postoperative visual outcomes, that is, corneal higher-order aberrations (HOAs) and visual quality, of patients with an angle kappa greater than 0.30 mm who underwent angle kappa adjustment during small-incision lenticule extraction (SMILE) 2 years after surgery compared to eyes with an angle kappa less than 0.30 mm. METHODS: This was a retrospective study and included 12 patients from October 2019 to December 2019 who underwent the SMILE procedure for correction of myopia and myopic astigmatism and had one eye with a large kappa angle and another eye with a small kappa angle. Twenty-four months after surgery, an optical quality analysis system (OQAS II; Visiometrics, Terrassa, Spain) was used to measure the modulation transfer function cutoff frequency (MTF(cutoff)), Strehl2D ratio, and objective scatter index (OSI). HOAs were measured with a Tracey iTrace Visual Function Analyzer (Tracey version 6.1.0; Tracey Technologies, Houston, TX, USA). Assessment of subjective visual quality was achieved using the quality of vision (QOV) questionnaire. RESULTS: At 24 months postoperatively, the mean spherical equivalent (SE) refraction was − 0.32 ± 0.40 and − 0.31 ± 0.35 in the S-kappa group (kappa <0.3 mm) and the L-kappa group (kappa ≥0.3 mm), respectively (P > 0.05). The mean OSI was 0.73 ± 0.32 and 0.81 ± 0.47, respectively (P > 0.05). There was no significant difference in MTF(cutoff) and Strehl2D ratio between the two groups (P > 0.05). Total HOA, coma, spherical, trefoil, and secondary astigmatism were not significantly different (P > 0.05) between the two groups. CONCLUSION: Adjustment of angle kappa during SMILE helps reduce the decentration, results in less HOAs, and promotes visual quality. It provides a reliable method to optimize the treatment concentration in SMILE. Wolters Kluwer - Medknow 2023-05 2023-05-17 /pmc/articles/PMC10391436/ /pubmed/37203043 http://dx.doi.org/10.4103/IJO.IJO_3017_22 Text en Copyright: © 2023 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Xie, Mengzhen Deng, Yingping Sun, Chengshu Qiu, Lemei Tang, Jing Higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: A 2-year follow-up |
title | Higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: A 2-year follow-up |
title_full | Higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: A 2-year follow-up |
title_fullStr | Higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: A 2-year follow-up |
title_full_unstemmed | Higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: A 2-year follow-up |
title_short | Higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: A 2-year follow-up |
title_sort | higher-order aberrations and visual quality after incision lenticule extraction surgery with intraoperative angle kappa adjustments between small and large kappa patients: a 2-year follow-up |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10391436/ https://www.ncbi.nlm.nih.gov/pubmed/37203043 http://dx.doi.org/10.4103/IJO.IJO_3017_22 |
work_keys_str_mv | AT xiemengzhen higherorderaberrationsandvisualqualityafterincisionlenticuleextractionsurgerywithintraoperativeanglekappaadjustmentsbetweensmallandlargekappapatientsa2yearfollowup AT dengyingping higherorderaberrationsandvisualqualityafterincisionlenticuleextractionsurgerywithintraoperativeanglekappaadjustmentsbetweensmallandlargekappapatientsa2yearfollowup AT sunchengshu higherorderaberrationsandvisualqualityafterincisionlenticuleextractionsurgerywithintraoperativeanglekappaadjustmentsbetweensmallandlargekappapatientsa2yearfollowup AT qiulemei higherorderaberrationsandvisualqualityafterincisionlenticuleextractionsurgerywithintraoperativeanglekappaadjustmentsbetweensmallandlargekappapatientsa2yearfollowup AT tangjing higherorderaberrationsandvisualqualityafterincisionlenticuleextractionsurgerywithintraoperativeanglekappaadjustmentsbetweensmallandlargekappapatientsa2yearfollowup |