Cargando…

Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults

BACKGROUND: Typically, shoulder range of motion (ROM) measurements are performed in a clinic setting, where physicians, physical therapists (PTs), and occupational therapists make use of a goniometer. PURPOSE: To determine the accuracy of a smartphone-based ROM software application (app) in assessin...

Descripción completa

Detalles Bibliográficos
Autores principales: Soeters, Rupali, Damodar, Dhanur, Borman, Nicole, Jacobson, Kendal, Shi, Jing, Pillai, Raji, Mehran, Nima
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392163/
https://www.ncbi.nlm.nih.gov/pubmed/37533501
http://dx.doi.org/10.1177/23259671231187297
_version_ 1785082890871111680
author Soeters, Rupali
Damodar, Dhanur
Borman, Nicole
Jacobson, Kendal
Shi, Jing
Pillai, Raji
Mehran, Nima
author_facet Soeters, Rupali
Damodar, Dhanur
Borman, Nicole
Jacobson, Kendal
Shi, Jing
Pillai, Raji
Mehran, Nima
author_sort Soeters, Rupali
collection PubMed
description BACKGROUND: Typically, shoulder range of motion (ROM) measurements are performed in a clinic setting, where physicians, physical therapists (PTs), and occupational therapists make use of a goniometer. PURPOSE: To determine the accuracy of a smartphone-based ROM software application (app) in assessing active shoulder ROM and compare the measurements with traditional goniometry as measured by a PT. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: This prospective, nonblinded study was conducted at a single institution with adult asymptomatic participants with full active ROM of both shoulders. Participants were enrolled between June 1 and 15, 2021. Each participant self-assessed their active shoulder ROM using the PeerWell smartphone app. A single PT concurrently measured each participant’s active shoulder ROM using a handheld universal goniometer. Bilateral shoulder ROM (forward flexion, abduction [AB], external rotation, internal rotation [IR], and extension) was measured 2 times for each participant. Interrater reliability between the smartphone app and PT measurements as well as intrarater reliability for each method of measurement were assessed using the intraclass correlation coefficient (ICC), and limits of agreement were analyzed for the difference in measurement methods. RESULTS: Data were analyzed for 60 shoulders (30 right, 30 left) from 30 participants (mean age, 31.4 ± 11.7 years; 73% female). The interrater reliability between the 2 methods was excellent for all movements (ICCs, 0.90-0.96). For all movements except shoulder AB, the mean difference in the measurements between the 2 methods was <1.3°; the mean difference in AB ROM was 2.08°. For all movements except IR, both PTs and the app showed excellent intrarater reliability (ICCs >0.90); for IR, good intrarater reliability (ICC ≥0.75) was observed. CONCLUSION: The PeerWell smartphone app provided measurements comparable with manual measurements taken by a PT using a goniometer. These data provide evidence that the smartphone app is a reliable and valid tool for measuring shoulder ROM and show promise for measuring and monitoring patient ROM remotely.
format Online
Article
Text
id pubmed-10392163
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-103921632023-08-02 Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults Soeters, Rupali Damodar, Dhanur Borman, Nicole Jacobson, Kendal Shi, Jing Pillai, Raji Mehran, Nima Orthop J Sports Med Article BACKGROUND: Typically, shoulder range of motion (ROM) measurements are performed in a clinic setting, where physicians, physical therapists (PTs), and occupational therapists make use of a goniometer. PURPOSE: To determine the accuracy of a smartphone-based ROM software application (app) in assessing active shoulder ROM and compare the measurements with traditional goniometry as measured by a PT. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: This prospective, nonblinded study was conducted at a single institution with adult asymptomatic participants with full active ROM of both shoulders. Participants were enrolled between June 1 and 15, 2021. Each participant self-assessed their active shoulder ROM using the PeerWell smartphone app. A single PT concurrently measured each participant’s active shoulder ROM using a handheld universal goniometer. Bilateral shoulder ROM (forward flexion, abduction [AB], external rotation, internal rotation [IR], and extension) was measured 2 times for each participant. Interrater reliability between the smartphone app and PT measurements as well as intrarater reliability for each method of measurement were assessed using the intraclass correlation coefficient (ICC), and limits of agreement were analyzed for the difference in measurement methods. RESULTS: Data were analyzed for 60 shoulders (30 right, 30 left) from 30 participants (mean age, 31.4 ± 11.7 years; 73% female). The interrater reliability between the 2 methods was excellent for all movements (ICCs, 0.90-0.96). For all movements except shoulder AB, the mean difference in the measurements between the 2 methods was <1.3°; the mean difference in AB ROM was 2.08°. For all movements except IR, both PTs and the app showed excellent intrarater reliability (ICCs >0.90); for IR, good intrarater reliability (ICC ≥0.75) was observed. CONCLUSION: The PeerWell smartphone app provided measurements comparable with manual measurements taken by a PT using a goniometer. These data provide evidence that the smartphone app is a reliable and valid tool for measuring shoulder ROM and show promise for measuring and monitoring patient ROM remotely. SAGE Publications 2023-07-31 /pmc/articles/PMC10392163/ /pubmed/37533501 http://dx.doi.org/10.1177/23259671231187297 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Soeters, Rupali
Damodar, Dhanur
Borman, Nicole
Jacobson, Kendal
Shi, Jing
Pillai, Raji
Mehran, Nima
Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults
title Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults
title_full Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults
title_fullStr Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults
title_full_unstemmed Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults
title_short Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults
title_sort accuracy of a smartphone software application compared with a handheld goniometer for measuring shoulder range of motion in asymptomatic adults
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392163/
https://www.ncbi.nlm.nih.gov/pubmed/37533501
http://dx.doi.org/10.1177/23259671231187297
work_keys_str_mv AT soetersrupali accuracyofasmartphonesoftwareapplicationcomparedwithahandheldgoniometerformeasuringshoulderrangeofmotioninasymptomaticadults
AT damodardhanur accuracyofasmartphonesoftwareapplicationcomparedwithahandheldgoniometerformeasuringshoulderrangeofmotioninasymptomaticadults
AT bormannicole accuracyofasmartphonesoftwareapplicationcomparedwithahandheldgoniometerformeasuringshoulderrangeofmotioninasymptomaticadults
AT jacobsonkendal accuracyofasmartphonesoftwareapplicationcomparedwithahandheldgoniometerformeasuringshoulderrangeofmotioninasymptomaticadults
AT shijing accuracyofasmartphonesoftwareapplicationcomparedwithahandheldgoniometerformeasuringshoulderrangeofmotioninasymptomaticadults
AT pillairaji accuracyofasmartphonesoftwareapplicationcomparedwithahandheldgoniometerformeasuringshoulderrangeofmotioninasymptomaticadults
AT mehrannima accuracyofasmartphonesoftwareapplicationcomparedwithahandheldgoniometerformeasuringshoulderrangeofmotioninasymptomaticadults