Cargando…

Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year

OBJECTIVES: To compare patient reported outcomes, range of motion (ROM), and complications of patients undergoing arthroscopic rotator cuff repair (RCR) augmented with a bioinductive patch compared to standard repair. METHODS: A retrospective review of patients undergoing primary arthroscopic rotato...

Descripción completa

Detalles Bibliográficos
Autores principales: Burdick, Gabriel, Fathima, Bushra, Gaudiani, Michael, Wolternik, Trevor, Haan, Jager, Kasto, Johnny, Kolowich, Patricia, Muh, Stephanie, Castle, Joshua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392404/
http://dx.doi.org/10.1177/2325967123S00160
_version_ 1785082952534720512
author Burdick, Gabriel
Fathima, Bushra
Gaudiani, Michael
Wolternik, Trevor
Haan, Jager
Kasto, Johnny
Kolowich, Patricia
Muh, Stephanie
Castle, Joshua
author_facet Burdick, Gabriel
Fathima, Bushra
Gaudiani, Michael
Wolternik, Trevor
Haan, Jager
Kasto, Johnny
Kolowich, Patricia
Muh, Stephanie
Castle, Joshua
author_sort Burdick, Gabriel
collection PubMed
description OBJECTIVES: To compare patient reported outcomes, range of motion (ROM), and complications of patients undergoing arthroscopic rotator cuff repair (RCR) augmented with a bioinductive patch compared to standard repair. METHODS: A retrospective review of patients undergoing primary arthroscopic rotator cuff repair with and without bioinductive bovine collagen patch augmentation for supraspinatus/infraspinatus tears from 2016 to 2021 at a single institution was performed. Patients were excluded based on the following criteria: age <18 years, open or mini-open rotator cuff repair, prior surgery of the affected shoulder (except diagnostic arthroscopy), rheumatological disease, active infection, or cancer. Patients who underwent RCR augmented with a collagen patch were matched 1:1 to those undergoing standard rotator cuff repair based on tear thickness and size. The electronic medical record was used to obtain patient demographics, range of motion (ROM), and assess for complications. MRI or ultrasound was used to confirm tear and classify size using the DeOrio and Cofield classification of small (<1cm), medium (1-3cm), large (3-5cm), and massive (>5cm). In addition, Patient Reported Outcome Information System (PROMIS) scores were recorded at preoperative, 6 weeks, 3 months, 6 months, and 1 year postoperative time points. RESULTS: Fifty-four patients underwent RCR with patch augmentation and were matched to 54 controls. No significant differences were found between groups in terms of age (56.7 ± 9.0 patch vs. 59.3 ± 8.5 years control, p=0.12), sex, smoking, diabetes, degenerative vs. traumatic tears (50% vs. 50.9%, p=1.0), partial vs. full thickness (38.9% vs. 25.5%, p=0.2), as well as tear size (p=0.8). ROM in forward flexion (FF) and abduction (ABD) were significantly increased at 1 year compared to controls (FF 162 +/- 22 vs. 148 +/- 26 degrees, p<0.01; ABD 137 +/- 37 vs. 117 +/- 40, p=0.047). No differences were seen for PROMIS- UE, but PROMIS-PI scores were significantly lower in the patch group at 6 months (55.2 +/- 8.0 vs. 61.9 +/- 2.0, p<0.01) and 1 year (56.0 +/- 7.5 vs. 62.1 +/- 3.6, p<.01). The patch group had 7 retears compared to 0 controls (13.0% vs 0%, 2/7 for subscapularis tears not augmented) and 1 biceps tenodesis rupture, with 5 requiring revision surgery. CONCLUSIONS: Bioinductive patch augmentation for RCR demonstrated increased ROM, but equivalent physical function after 1 year.
format Online
Article
Text
id pubmed-10392404
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-103924042023-08-02 Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year Burdick, Gabriel Fathima, Bushra Gaudiani, Michael Wolternik, Trevor Haan, Jager Kasto, Johnny Kolowich, Patricia Muh, Stephanie Castle, Joshua Orthop J Sports Med Article OBJECTIVES: To compare patient reported outcomes, range of motion (ROM), and complications of patients undergoing arthroscopic rotator cuff repair (RCR) augmented with a bioinductive patch compared to standard repair. METHODS: A retrospective review of patients undergoing primary arthroscopic rotator cuff repair with and without bioinductive bovine collagen patch augmentation for supraspinatus/infraspinatus tears from 2016 to 2021 at a single institution was performed. Patients were excluded based on the following criteria: age <18 years, open or mini-open rotator cuff repair, prior surgery of the affected shoulder (except diagnostic arthroscopy), rheumatological disease, active infection, or cancer. Patients who underwent RCR augmented with a collagen patch were matched 1:1 to those undergoing standard rotator cuff repair based on tear thickness and size. The electronic medical record was used to obtain patient demographics, range of motion (ROM), and assess for complications. MRI or ultrasound was used to confirm tear and classify size using the DeOrio and Cofield classification of small (<1cm), medium (1-3cm), large (3-5cm), and massive (>5cm). In addition, Patient Reported Outcome Information System (PROMIS) scores were recorded at preoperative, 6 weeks, 3 months, 6 months, and 1 year postoperative time points. RESULTS: Fifty-four patients underwent RCR with patch augmentation and were matched to 54 controls. No significant differences were found between groups in terms of age (56.7 ± 9.0 patch vs. 59.3 ± 8.5 years control, p=0.12), sex, smoking, diabetes, degenerative vs. traumatic tears (50% vs. 50.9%, p=1.0), partial vs. full thickness (38.9% vs. 25.5%, p=0.2), as well as tear size (p=0.8). ROM in forward flexion (FF) and abduction (ABD) were significantly increased at 1 year compared to controls (FF 162 +/- 22 vs. 148 +/- 26 degrees, p<0.01; ABD 137 +/- 37 vs. 117 +/- 40, p=0.047). No differences were seen for PROMIS- UE, but PROMIS-PI scores were significantly lower in the patch group at 6 months (55.2 +/- 8.0 vs. 61.9 +/- 2.0, p<0.01) and 1 year (56.0 +/- 7.5 vs. 62.1 +/- 3.6, p<.01). The patch group had 7 retears compared to 0 controls (13.0% vs 0%, 2/7 for subscapularis tears not augmented) and 1 biceps tenodesis rupture, with 5 requiring revision surgery. CONCLUSIONS: Bioinductive patch augmentation for RCR demonstrated increased ROM, but equivalent physical function after 1 year. SAGE Publications 2023-07-31 /pmc/articles/PMC10392404/ http://dx.doi.org/10.1177/2325967123S00160 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Burdick, Gabriel
Fathima, Bushra
Gaudiani, Michael
Wolternik, Trevor
Haan, Jager
Kasto, Johnny
Kolowich, Patricia
Muh, Stephanie
Castle, Joshua
Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year
title Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year
title_full Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year
title_fullStr Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year
title_full_unstemmed Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year
title_short Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year
title_sort poster 174: arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392404/
http://dx.doi.org/10.1177/2325967123S00160
work_keys_str_mv AT burdickgabriel poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year
AT fathimabushra poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year
AT gaudianimichael poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year
AT wolterniktrevor poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year
AT haanjager poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year
AT kastojohnny poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year
AT kolowichpatricia poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year
AT muhstephanie poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year
AT castlejoshua poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year