Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year
OBJECTIVES: To compare patient reported outcomes, range of motion (ROM), and complications of patients undergoing arthroscopic rotator cuff repair (RCR) augmented with a bioinductive patch compared to standard repair. METHODS: A retrospective review of patients undergoing primary arthroscopic rotato...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392404/ http://dx.doi.org/10.1177/2325967123S00160 |
_version_ | 1785082952534720512 |
---|---|
author | Burdick, Gabriel Fathima, Bushra Gaudiani, Michael Wolternik, Trevor Haan, Jager Kasto, Johnny Kolowich, Patricia Muh, Stephanie Castle, Joshua |
author_facet | Burdick, Gabriel Fathima, Bushra Gaudiani, Michael Wolternik, Trevor Haan, Jager Kasto, Johnny Kolowich, Patricia Muh, Stephanie Castle, Joshua |
author_sort | Burdick, Gabriel |
collection | PubMed |
description | OBJECTIVES: To compare patient reported outcomes, range of motion (ROM), and complications of patients undergoing arthroscopic rotator cuff repair (RCR) augmented with a bioinductive patch compared to standard repair. METHODS: A retrospective review of patients undergoing primary arthroscopic rotator cuff repair with and without bioinductive bovine collagen patch augmentation for supraspinatus/infraspinatus tears from 2016 to 2021 at a single institution was performed. Patients were excluded based on the following criteria: age <18 years, open or mini-open rotator cuff repair, prior surgery of the affected shoulder (except diagnostic arthroscopy), rheumatological disease, active infection, or cancer. Patients who underwent RCR augmented with a collagen patch were matched 1:1 to those undergoing standard rotator cuff repair based on tear thickness and size. The electronic medical record was used to obtain patient demographics, range of motion (ROM), and assess for complications. MRI or ultrasound was used to confirm tear and classify size using the DeOrio and Cofield classification of small (<1cm), medium (1-3cm), large (3-5cm), and massive (>5cm). In addition, Patient Reported Outcome Information System (PROMIS) scores were recorded at preoperative, 6 weeks, 3 months, 6 months, and 1 year postoperative time points. RESULTS: Fifty-four patients underwent RCR with patch augmentation and were matched to 54 controls. No significant differences were found between groups in terms of age (56.7 ± 9.0 patch vs. 59.3 ± 8.5 years control, p=0.12), sex, smoking, diabetes, degenerative vs. traumatic tears (50% vs. 50.9%, p=1.0), partial vs. full thickness (38.9% vs. 25.5%, p=0.2), as well as tear size (p=0.8). ROM in forward flexion (FF) and abduction (ABD) were significantly increased at 1 year compared to controls (FF 162 +/- 22 vs. 148 +/- 26 degrees, p<0.01; ABD 137 +/- 37 vs. 117 +/- 40, p=0.047). No differences were seen for PROMIS- UE, but PROMIS-PI scores were significantly lower in the patch group at 6 months (55.2 +/- 8.0 vs. 61.9 +/- 2.0, p<0.01) and 1 year (56.0 +/- 7.5 vs. 62.1 +/- 3.6, p<.01). The patch group had 7 retears compared to 0 controls (13.0% vs 0%, 2/7 for subscapularis tears not augmented) and 1 biceps tenodesis rupture, with 5 requiring revision surgery. CONCLUSIONS: Bioinductive patch augmentation for RCR demonstrated increased ROM, but equivalent physical function after 1 year. |
format | Online Article Text |
id | pubmed-10392404 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-103924042023-08-02 Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year Burdick, Gabriel Fathima, Bushra Gaudiani, Michael Wolternik, Trevor Haan, Jager Kasto, Johnny Kolowich, Patricia Muh, Stephanie Castle, Joshua Orthop J Sports Med Article OBJECTIVES: To compare patient reported outcomes, range of motion (ROM), and complications of patients undergoing arthroscopic rotator cuff repair (RCR) augmented with a bioinductive patch compared to standard repair. METHODS: A retrospective review of patients undergoing primary arthroscopic rotator cuff repair with and without bioinductive bovine collagen patch augmentation for supraspinatus/infraspinatus tears from 2016 to 2021 at a single institution was performed. Patients were excluded based on the following criteria: age <18 years, open or mini-open rotator cuff repair, prior surgery of the affected shoulder (except diagnostic arthroscopy), rheumatological disease, active infection, or cancer. Patients who underwent RCR augmented with a collagen patch were matched 1:1 to those undergoing standard rotator cuff repair based on tear thickness and size. The electronic medical record was used to obtain patient demographics, range of motion (ROM), and assess for complications. MRI or ultrasound was used to confirm tear and classify size using the DeOrio and Cofield classification of small (<1cm), medium (1-3cm), large (3-5cm), and massive (>5cm). In addition, Patient Reported Outcome Information System (PROMIS) scores were recorded at preoperative, 6 weeks, 3 months, 6 months, and 1 year postoperative time points. RESULTS: Fifty-four patients underwent RCR with patch augmentation and were matched to 54 controls. No significant differences were found between groups in terms of age (56.7 ± 9.0 patch vs. 59.3 ± 8.5 years control, p=0.12), sex, smoking, diabetes, degenerative vs. traumatic tears (50% vs. 50.9%, p=1.0), partial vs. full thickness (38.9% vs. 25.5%, p=0.2), as well as tear size (p=0.8). ROM in forward flexion (FF) and abduction (ABD) were significantly increased at 1 year compared to controls (FF 162 +/- 22 vs. 148 +/- 26 degrees, p<0.01; ABD 137 +/- 37 vs. 117 +/- 40, p=0.047). No differences were seen for PROMIS- UE, but PROMIS-PI scores were significantly lower in the patch group at 6 months (55.2 +/- 8.0 vs. 61.9 +/- 2.0, p<0.01) and 1 year (56.0 +/- 7.5 vs. 62.1 +/- 3.6, p<.01). The patch group had 7 retears compared to 0 controls (13.0% vs 0%, 2/7 for subscapularis tears not augmented) and 1 biceps tenodesis rupture, with 5 requiring revision surgery. CONCLUSIONS: Bioinductive patch augmentation for RCR demonstrated increased ROM, but equivalent physical function after 1 year. SAGE Publications 2023-07-31 /pmc/articles/PMC10392404/ http://dx.doi.org/10.1177/2325967123S00160 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions. |
spellingShingle | Article Burdick, Gabriel Fathima, Bushra Gaudiani, Michael Wolternik, Trevor Haan, Jager Kasto, Johnny Kolowich, Patricia Muh, Stephanie Castle, Joshua Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year |
title | Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year |
title_full | Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year |
title_fullStr | Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year |
title_full_unstemmed | Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year |
title_short | Poster 174: Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year |
title_sort | poster 174: arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient- reported outcomes at 1 year |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392404/ http://dx.doi.org/10.1177/2325967123S00160 |
work_keys_str_mv | AT burdickgabriel poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year AT fathimabushra poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year AT gaudianimichael poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year AT wolterniktrevor poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year AT haanjager poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year AT kastojohnny poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year AT kolowichpatricia poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year AT muhstephanie poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year AT castlejoshua poster174arthroscopicrotatorcuffrepairwithbioinductivepatchachievesequivalentpatientreportedoutcomesat1year |