Poster 198: Forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy

OBJECTIVES: Accurate assessment of shoulder range of motion (ROM) is important for both initial evaluation and evaluating rehabilitation progress. Recently, digital platforms have been developed which assess ROM with the use of a front-facing camera available on smartphones. Such tools allow ROM to...

Descripción completa

Detalles Bibliográficos
Autores principales: Denard, Patrick, Higgins, Laurence, Gobezie, Reuben, Shishani, Yousef
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392489/
http://dx.doi.org/10.1177/2325967123S00183
_version_ 1785082973880582144
author Denard, Patrick
Higgins, Laurence
Gobezie, Reuben
Shishani, Yousef
author_facet Denard, Patrick
Higgins, Laurence
Gobezie, Reuben
Shishani, Yousef
author_sort Denard, Patrick
collection PubMed
description OBJECTIVES: Accurate assessment of shoulder range of motion (ROM) is important for both initial evaluation and evaluating rehabilitation progress. Recently, digital platforms have been developed which assess ROM with the use of a front-facing camera available on smartphones. Such tools allow ROM to be objectively assessed and monitored remotely but require validation. The purpose of this study was, therefore, to compare forward flexion (FF) measured with a digital health platform (PT Genie, Orlando, Fl) (Figure 1) to in-office measurements with a hand-held digital goniometer (Halo Medical Devices, Australia) (Figure 2) METHODS: A prospective evaluation was performed on consecutive patients evaluated in a single shoulder specialist practice. Thirty -two consecutive patients, including 16 males and 16 females, aged 58.5 ± 17.4 years (range 24-80) participated in the study. All participants completed 3 consecutive FF efforts measured first with a digital goniometer, followed by 3 consecutive FF efforts measured with the front-facing camera. All digital goniometer measurements were recorded by the same examiner. All measurements using the front-facing camera were obtained with an iPhone 11 running iOS 15.4.1, and the PT Genie platform (Figure 1). The mean from the 3 measurements was calculated and the mean differences between the two measurement options were then compared using the simple Student t- test. Analysis was completed using SPSS version 17 (SPSS Inc., Chicago). RESULTS: For both the digital goniometer and front-facing camera groups there were no significant differences within the 3 measurements (p > 0.05). Mean FF measured with the digital goniometer was 120.1° ± 24.7° (range 71.7° - 164.7°) compared to 123.5° ± 26.0° (range 74.7° – 173.0°) with the front- facing camera, for a difference of 3.4° between groups (p<0.001). CONCLUSIONS: These findings suggest that the measurement of FF is comparable between a digital goniometer and a front-facing camera. While small differences were seen between the methods, the differences are not likely clinically relevant, and more importantly, the findings were internally consistent. These preliminary findings help in establishing the use of such an application for remote physical therapy. Further study is needed to assess other planes of range of motion and obtain data in a larger cohort.
format Online
Article
Text
id pubmed-10392489
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-103924892023-08-02 Poster 198: Forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy Denard, Patrick Higgins, Laurence Gobezie, Reuben Shishani, Yousef Orthop J Sports Med Article OBJECTIVES: Accurate assessment of shoulder range of motion (ROM) is important for both initial evaluation and evaluating rehabilitation progress. Recently, digital platforms have been developed which assess ROM with the use of a front-facing camera available on smartphones. Such tools allow ROM to be objectively assessed and monitored remotely but require validation. The purpose of this study was, therefore, to compare forward flexion (FF) measured with a digital health platform (PT Genie, Orlando, Fl) (Figure 1) to in-office measurements with a hand-held digital goniometer (Halo Medical Devices, Australia) (Figure 2) METHODS: A prospective evaluation was performed on consecutive patients evaluated in a single shoulder specialist practice. Thirty -two consecutive patients, including 16 males and 16 females, aged 58.5 ± 17.4 years (range 24-80) participated in the study. All participants completed 3 consecutive FF efforts measured first with a digital goniometer, followed by 3 consecutive FF efforts measured with the front-facing camera. All digital goniometer measurements were recorded by the same examiner. All measurements using the front-facing camera were obtained with an iPhone 11 running iOS 15.4.1, and the PT Genie platform (Figure 1). The mean from the 3 measurements was calculated and the mean differences between the two measurement options were then compared using the simple Student t- test. Analysis was completed using SPSS version 17 (SPSS Inc., Chicago). RESULTS: For both the digital goniometer and front-facing camera groups there were no significant differences within the 3 measurements (p > 0.05). Mean FF measured with the digital goniometer was 120.1° ± 24.7° (range 71.7° - 164.7°) compared to 123.5° ± 26.0° (range 74.7° – 173.0°) with the front- facing camera, for a difference of 3.4° between groups (p<0.001). CONCLUSIONS: These findings suggest that the measurement of FF is comparable between a digital goniometer and a front-facing camera. While small differences were seen between the methods, the differences are not likely clinically relevant, and more importantly, the findings were internally consistent. These preliminary findings help in establishing the use of such an application for remote physical therapy. Further study is needed to assess other planes of range of motion and obtain data in a larger cohort. SAGE Publications 2023-07-31 /pmc/articles/PMC10392489/ http://dx.doi.org/10.1177/2325967123S00183 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Denard, Patrick
Higgins, Laurence
Gobezie, Reuben
Shishani, Yousef
Poster 198: Forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy
title Poster 198: Forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy
title_full Poster 198: Forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy
title_fullStr Poster 198: Forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy
title_full_unstemmed Poster 198: Forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy
title_short Poster 198: Forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy
title_sort poster 198: forward flexion can reliably be measured with a front-facing camera used for at-home physical therapy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392489/
http://dx.doi.org/10.1177/2325967123S00183
work_keys_str_mv AT denardpatrick poster198forwardflexioncanreliablybemeasuredwithafrontfacingcamerausedforathomephysicaltherapy
AT higginslaurence poster198forwardflexioncanreliablybemeasuredwithafrontfacingcamerausedforathomephysicaltherapy
AT gobeziereuben poster198forwardflexioncanreliablybemeasuredwithafrontfacingcamerausedforathomephysicaltherapy
AT shishaniyousef poster198forwardflexioncanreliablybemeasuredwithafrontfacingcamerausedforathomephysicaltherapy