Cargando…

Video Grading of Descemet Membrane Endothelial Keratoplasty Surgery to Identify Surgeon Risk Factors for Graft Detachment and Rebubbling: A Post Hoc Observational Analysis of the Advanced Visualization In Corneal Surgery Evaluation Trial

The aim of this study was to explore video-graded intraoperative risk factors for graft detachment (GD) and rebubbling in Descemet membrane endothelial keratoplasty surgery. METHODS: A post hoc analysis of 65 eyes of 65 pseudophakic subjects with Fuchs endothelial dystrophy that underwent Descemet m...

Descripción completa

Detalles Bibliográficos
Autores principales: Muijzer, Marc B., Delbeke, Heleen, Dickman, Mor M., Nuijts, Rudy M. M. A., Jimale, Hanad, van Luijk, Chantal M., Imhof, Saskia M., Wisse, Robert P. L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cornea 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392889/
https://www.ncbi.nlm.nih.gov/pubmed/36730371
http://dx.doi.org/10.1097/ICO.0000000000003181
_version_ 1785083047475937280
author Muijzer, Marc B.
Delbeke, Heleen
Dickman, Mor M.
Nuijts, Rudy M. M. A.
Jimale, Hanad
van Luijk, Chantal M.
Imhof, Saskia M.
Wisse, Robert P. L.
author_facet Muijzer, Marc B.
Delbeke, Heleen
Dickman, Mor M.
Nuijts, Rudy M. M. A.
Jimale, Hanad
van Luijk, Chantal M.
Imhof, Saskia M.
Wisse, Robert P. L.
author_sort Muijzer, Marc B.
collection PubMed
description The aim of this study was to explore video-graded intraoperative risk factors for graft detachment (GD) and rebubbling in Descemet membrane endothelial keratoplasty surgery. METHODS: A post hoc analysis of 65 eyes of 65 pseudophakic subjects with Fuchs endothelial dystrophy that underwent Descemet membrane endothelial keratoplasty surgery as part of the Advanced Visualization In Corneal Surgery Evaluation trial. All surgical recordings were assessed by 2 graders using a structured assessment form. A multinominal regression was performed to estimate the independent effect of video-graded intraoperative factors on the incidence of GD and rebubbling. Secondary outcomes are corrected distance visual acuity and endothelial cell density. RESULTS: In total, 33 GDs were recorded, of which 17 required rebubbling. No significant predictors for GD or rebubbling were identified. However, the results revealed 2 clinically relevant patterns. An unfavorable graft configuration (ie, wrinkled, tight scroll, or taco-shaped) and a gas-bubble size smaller than the graft diameter were associated with an increased risk of GD [odds ratio (OR) 2.5 and OR 2.26, respectively] and rebubbling (OR 2.0 and OR 2.60, respectively). Inversely, a larger gas-bubble size was associated with a reduced risk of GD (OR 0.37) and rebubbling (OR 0.36). At 3 and 6 months postoperatively, corrected distance visual acuity was poorer in subjects requiring a rebubbling and endothelial cell density loss was higher in subjects with a partial GD. CONCLUSIONS: Our analysis revealed that the gas-bubble size and graft shape/geometry seem to be relevant clinical factors for GD and rebubbling, whereas descemetorhexis difficulty, degree of graft manipulation, graft overlap, and surgical iridectomy were not associated with an increased risk.
format Online
Article
Text
id pubmed-10392889
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cornea
record_format MEDLINE/PubMed
spelling pubmed-103928892023-08-02 Video Grading of Descemet Membrane Endothelial Keratoplasty Surgery to Identify Surgeon Risk Factors for Graft Detachment and Rebubbling: A Post Hoc Observational Analysis of the Advanced Visualization In Corneal Surgery Evaluation Trial Muijzer, Marc B. Delbeke, Heleen Dickman, Mor M. Nuijts, Rudy M. M. A. Jimale, Hanad van Luijk, Chantal M. Imhof, Saskia M. Wisse, Robert P. L. Cornea Clinical Science The aim of this study was to explore video-graded intraoperative risk factors for graft detachment (GD) and rebubbling in Descemet membrane endothelial keratoplasty surgery. METHODS: A post hoc analysis of 65 eyes of 65 pseudophakic subjects with Fuchs endothelial dystrophy that underwent Descemet membrane endothelial keratoplasty surgery as part of the Advanced Visualization In Corneal Surgery Evaluation trial. All surgical recordings were assessed by 2 graders using a structured assessment form. A multinominal regression was performed to estimate the independent effect of video-graded intraoperative factors on the incidence of GD and rebubbling. Secondary outcomes are corrected distance visual acuity and endothelial cell density. RESULTS: In total, 33 GDs were recorded, of which 17 required rebubbling. No significant predictors for GD or rebubbling were identified. However, the results revealed 2 clinically relevant patterns. An unfavorable graft configuration (ie, wrinkled, tight scroll, or taco-shaped) and a gas-bubble size smaller than the graft diameter were associated with an increased risk of GD [odds ratio (OR) 2.5 and OR 2.26, respectively] and rebubbling (OR 2.0 and OR 2.60, respectively). Inversely, a larger gas-bubble size was associated with a reduced risk of GD (OR 0.37) and rebubbling (OR 0.36). At 3 and 6 months postoperatively, corrected distance visual acuity was poorer in subjects requiring a rebubbling and endothelial cell density loss was higher in subjects with a partial GD. CONCLUSIONS: Our analysis revealed that the gas-bubble size and graft shape/geometry seem to be relevant clinical factors for GD and rebubbling, whereas descemetorhexis difficulty, degree of graft manipulation, graft overlap, and surgical iridectomy were not associated with an increased risk. Cornea 2023-09 2022-11-21 /pmc/articles/PMC10392889/ /pubmed/36730371 http://dx.doi.org/10.1097/ICO.0000000000003181 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Science
Muijzer, Marc B.
Delbeke, Heleen
Dickman, Mor M.
Nuijts, Rudy M. M. A.
Jimale, Hanad
van Luijk, Chantal M.
Imhof, Saskia M.
Wisse, Robert P. L.
Video Grading of Descemet Membrane Endothelial Keratoplasty Surgery to Identify Surgeon Risk Factors for Graft Detachment and Rebubbling: A Post Hoc Observational Analysis of the Advanced Visualization In Corneal Surgery Evaluation Trial
title Video Grading of Descemet Membrane Endothelial Keratoplasty Surgery to Identify Surgeon Risk Factors for Graft Detachment and Rebubbling: A Post Hoc Observational Analysis of the Advanced Visualization In Corneal Surgery Evaluation Trial
title_full Video Grading of Descemet Membrane Endothelial Keratoplasty Surgery to Identify Surgeon Risk Factors for Graft Detachment and Rebubbling: A Post Hoc Observational Analysis of the Advanced Visualization In Corneal Surgery Evaluation Trial
title_fullStr Video Grading of Descemet Membrane Endothelial Keratoplasty Surgery to Identify Surgeon Risk Factors for Graft Detachment and Rebubbling: A Post Hoc Observational Analysis of the Advanced Visualization In Corneal Surgery Evaluation Trial
title_full_unstemmed Video Grading of Descemet Membrane Endothelial Keratoplasty Surgery to Identify Surgeon Risk Factors for Graft Detachment and Rebubbling: A Post Hoc Observational Analysis of the Advanced Visualization In Corneal Surgery Evaluation Trial
title_short Video Grading of Descemet Membrane Endothelial Keratoplasty Surgery to Identify Surgeon Risk Factors for Graft Detachment and Rebubbling: A Post Hoc Observational Analysis of the Advanced Visualization In Corneal Surgery Evaluation Trial
title_sort video grading of descemet membrane endothelial keratoplasty surgery to identify surgeon risk factors for graft detachment and rebubbling: a post hoc observational analysis of the advanced visualization in corneal surgery evaluation trial
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10392889/
https://www.ncbi.nlm.nih.gov/pubmed/36730371
http://dx.doi.org/10.1097/ICO.0000000000003181
work_keys_str_mv AT muijzermarcb videogradingofdescemetmembraneendothelialkeratoplastysurgerytoidentifysurgeonriskfactorsforgraftdetachmentandrebubblingaposthocobservationalanalysisoftheadvancedvisualizationincornealsurgeryevaluationtrial
AT delbekeheleen videogradingofdescemetmembraneendothelialkeratoplastysurgerytoidentifysurgeonriskfactorsforgraftdetachmentandrebubblingaposthocobservationalanalysisoftheadvancedvisualizationincornealsurgeryevaluationtrial
AT dickmanmorm videogradingofdescemetmembraneendothelialkeratoplastysurgerytoidentifysurgeonriskfactorsforgraftdetachmentandrebubblingaposthocobservationalanalysisoftheadvancedvisualizationincornealsurgeryevaluationtrial
AT nuijtsrudymma videogradingofdescemetmembraneendothelialkeratoplastysurgerytoidentifysurgeonriskfactorsforgraftdetachmentandrebubblingaposthocobservationalanalysisoftheadvancedvisualizationincornealsurgeryevaluationtrial
AT jimalehanad videogradingofdescemetmembraneendothelialkeratoplastysurgerytoidentifysurgeonriskfactorsforgraftdetachmentandrebubblingaposthocobservationalanalysisoftheadvancedvisualizationincornealsurgeryevaluationtrial
AT vanluijkchantalm videogradingofdescemetmembraneendothelialkeratoplastysurgerytoidentifysurgeonriskfactorsforgraftdetachmentandrebubblingaposthocobservationalanalysisoftheadvancedvisualizationincornealsurgeryevaluationtrial
AT imhofsaskiam videogradingofdescemetmembraneendothelialkeratoplastysurgerytoidentifysurgeonriskfactorsforgraftdetachmentandrebubblingaposthocobservationalanalysisoftheadvancedvisualizationincornealsurgeryevaluationtrial
AT wisserobertpl videogradingofdescemetmembraneendothelialkeratoplastysurgerytoidentifysurgeonriskfactorsforgraftdetachmentandrebubblingaposthocobservationalanalysisoftheadvancedvisualizationincornealsurgeryevaluationtrial