Cargando…

Effect of Dural-Puncture Epidural vs Standard Epidural for Epidural Extension on Onset Time of Surgical Anesthesia in Elective Cesarean Delivery: A Randomized Clinical Trial

IMPORTANCE: Dural-puncture epidural (DPE) and standard epidural are common modes of neuraxial labor analgesia. Little is known about conversion of DPE-initiated labor analgesia to surgical anesthesia for cesarean delivery. OBJECTIVE: To determine whether DPE provides a faster onset and better-qualit...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharawi, Nadir, Williams, Matthew, Athar, Waseem, Martinello, Caroline, Stoner, Kyle, Taylor, Cameron, Guo, Nan, Sultan, Pervez, Mhyre, Jill M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Medical Association 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10394571/
https://www.ncbi.nlm.nih.gov/pubmed/37526934
http://dx.doi.org/10.1001/jamanetworkopen.2023.26710
Descripción
Sumario:IMPORTANCE: Dural-puncture epidural (DPE) and standard epidural are common modes of neuraxial labor analgesia. Little is known about conversion of DPE-initiated labor analgesia to surgical anesthesia for cesarean delivery. OBJECTIVE: To determine whether DPE provides a faster onset and better-quality block compared with the standard epidural technique for cesarean delivery. DESIGN, SETTING, AND PARTICIPANTS: This double-blind, randomized clinical trial was conducted between April 2019 and October 2022 at a tertiary care university hospital (University of Arkansas for Medical Sciences). Participants included women aged 18 years and older undergoing scheduled cesarean delivery with a singleton pregnancy. INTERVENTIONS: Participants were randomized to receive DPE or standard epidural in the labor and delivery room. A T10 sensory block was achieved and maintained using a low concentration of bupivacaine with fentanyl through the epidural catheter until the time of surgery. Epidural extension anesthesia was initiated in the operating room. MAIN OUTCOMES AND MEASURES: The primary outcome was the time taken from chloroprocaine administration to surgical anesthesia (T6 sensory block). The secondary outcome was the quality of epidural anesthesia, as defined by a composite of the following factors: (1) failure to achieve a T10 bilateral block preoperatively in the delivery room, (2) failure to achieve a surgical block at T6 within 15 minutes of chloroprocaine administration, (3) requirement for intraoperative analgesia, (4) repeat neuraxial procedure, and (5) conversion to general anesthesia. RESULTS: Among 140 women (mean [SD] age, 30.1 [5.2] years), 70 were randomized to the DPE group, and 70 were randomized to the standard epidural group. The DPE group had a faster onset time to surgical anesthesia compared with the standard epidural group (median [IQR], 422 [290-546] seconds vs 655 [437-926] seconds; median [IQR] difference, 233 [104-369] seconds). The composite rates of lower quality anesthesia were 15.7% (11 of 70 women) in the DPE group and 36.3% (24 of 66 women) in the standard epidural group (odds ratio, 0.33; 95% CI, 0.14-0.74; P = .007). CONCLUSIONS AND RELEVANCE: Anesthesia initiated following a DPE technique resulted in faster onset and improved block quality during epidural extension compared with initiation with a standard epidural technique. Further studies are needed to confirm these findings in the setting of intrapartum cesarean delivery. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03915574