Cargando…
Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement
BACKGROUND: Measurement of the optic nerve sheath diameter (ONSD) via ultrasonography has been proposed as a non-invasive metric of intracranial pressure that may be employed during in-field patient triage. However, first responders are not typically trained to conduct sonographic exams and/or do no...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10397168/ https://www.ncbi.nlm.nih.gov/pubmed/37530991 http://dx.doi.org/10.1186/s13089-023-00331-8 |
_version_ | 1785083860208320512 |
---|---|
author | Moore, Brad T. Osika, Tom Satterly, Steven Shah, Shreyansh Thirion, Tim Hampton, Spencer Aylward, Stephen Montgomery, Sean |
author_facet | Moore, Brad T. Osika, Tom Satterly, Steven Shah, Shreyansh Thirion, Tim Hampton, Spencer Aylward, Stephen Montgomery, Sean |
author_sort | Moore, Brad T. |
collection | PubMed |
description | BACKGROUND: Measurement of the optic nerve sheath diameter (ONSD) via ultrasonography has been proposed as a non-invasive metric of intracranial pressure that may be employed during in-field patient triage. However, first responders are not typically trained to conduct sonographic exams and/or do not have access to an expensive ultrasound device. Therefore, for successful deployment of ONSD measurement in-field, we believe that first responders must have access to low-cost, portable ultrasound and be assisted by artificial intelligence (AI) systems that can automatically interpret the optic nerve sheath ultrasound scan. We examine the suitability of five commercially available, low-cost, portable ultrasound devices that can be combined with future artificial intelligence algorithms to reduce the training required for and cost of in-field optic nerve sheath diameter measurement. This paper is focused on the quality of the images generated by these low-cost probes. We report results of a clinician preference survey and compare with a lab analysis of three quantitative image quality metrics across devices. We also examine the suitability of the devices in a hypothetical far-forward deployment using operators unskilled in ultrasound, with the assumption of a future onboard AI video interpreter. RESULTS: We find statistically significant differences in clinician ranking of the devices in the following categories: “Image Quality”, “Ease of Acquisition”, “Software”, and “Overall ONSD”. We show differences in signal-to-noise ratio, generalized contrast-to-noise ratio, point-spread function across the devices. These differences in image quality result in a statistically significant difference in manual ONSD measurement. Finally, we show that sufficiently wide transducers can capture the optic nerve sheath during blind (no visible B-mode) scans performed by operators unskilled in sonography. CONCLUSIONS: Ultrasound of the optic nerve sheath has the potential to be a convenient, non-invasive, point-of-injury or triage measure for elevated intracranial pressure in cases of traumatic brain injury. When transducer width is sufficient, briefly trained operators may obtain video sequences of the optic nerve sheath without guidance. This data suggest that unskilled operators are able to achieve the images needed for AI interpretation. However, we also show that image quality differences between ultrasound probes may influence manual ONSD measurements. |
format | Online Article Text |
id | pubmed-10397168 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-103971682023-08-04 Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement Moore, Brad T. Osika, Tom Satterly, Steven Shah, Shreyansh Thirion, Tim Hampton, Spencer Aylward, Stephen Montgomery, Sean Ultrasound J Original Article BACKGROUND: Measurement of the optic nerve sheath diameter (ONSD) via ultrasonography has been proposed as a non-invasive metric of intracranial pressure that may be employed during in-field patient triage. However, first responders are not typically trained to conduct sonographic exams and/or do not have access to an expensive ultrasound device. Therefore, for successful deployment of ONSD measurement in-field, we believe that first responders must have access to low-cost, portable ultrasound and be assisted by artificial intelligence (AI) systems that can automatically interpret the optic nerve sheath ultrasound scan. We examine the suitability of five commercially available, low-cost, portable ultrasound devices that can be combined with future artificial intelligence algorithms to reduce the training required for and cost of in-field optic nerve sheath diameter measurement. This paper is focused on the quality of the images generated by these low-cost probes. We report results of a clinician preference survey and compare with a lab analysis of three quantitative image quality metrics across devices. We also examine the suitability of the devices in a hypothetical far-forward deployment using operators unskilled in ultrasound, with the assumption of a future onboard AI video interpreter. RESULTS: We find statistically significant differences in clinician ranking of the devices in the following categories: “Image Quality”, “Ease of Acquisition”, “Software”, and “Overall ONSD”. We show differences in signal-to-noise ratio, generalized contrast-to-noise ratio, point-spread function across the devices. These differences in image quality result in a statistically significant difference in manual ONSD measurement. Finally, we show that sufficiently wide transducers can capture the optic nerve sheath during blind (no visible B-mode) scans performed by operators unskilled in sonography. CONCLUSIONS: Ultrasound of the optic nerve sheath has the potential to be a convenient, non-invasive, point-of-injury or triage measure for elevated intracranial pressure in cases of traumatic brain injury. When transducer width is sufficient, briefly trained operators may obtain video sequences of the optic nerve sheath without guidance. This data suggest that unskilled operators are able to achieve the images needed for AI interpretation. However, we also show that image quality differences between ultrasound probes may influence manual ONSD measurements. Springer International Publishing 2023-08-02 /pmc/articles/PMC10397168/ /pubmed/37530991 http://dx.doi.org/10.1186/s13089-023-00331-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Moore, Brad T. Osika, Tom Satterly, Steven Shah, Shreyansh Thirion, Tim Hampton, Spencer Aylward, Stephen Montgomery, Sean Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement |
title | Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement |
title_full | Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement |
title_fullStr | Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement |
title_full_unstemmed | Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement |
title_short | Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement |
title_sort | evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10397168/ https://www.ncbi.nlm.nih.gov/pubmed/37530991 http://dx.doi.org/10.1186/s13089-023-00331-8 |
work_keys_str_mv | AT moorebradt evaluationofcommerciallyavailablepointofcareultrasoundforautomatedopticnervesheathmeasurement AT osikatom evaluationofcommerciallyavailablepointofcareultrasoundforautomatedopticnervesheathmeasurement AT satterlysteven evaluationofcommerciallyavailablepointofcareultrasoundforautomatedopticnervesheathmeasurement AT shahshreyansh evaluationofcommerciallyavailablepointofcareultrasoundforautomatedopticnervesheathmeasurement AT thiriontim evaluationofcommerciallyavailablepointofcareultrasoundforautomatedopticnervesheathmeasurement AT hamptonspencer evaluationofcommerciallyavailablepointofcareultrasoundforautomatedopticnervesheathmeasurement AT aylwardstephen evaluationofcommerciallyavailablepointofcareultrasoundforautomatedopticnervesheathmeasurement AT montgomerysean evaluationofcommerciallyavailablepointofcareultrasoundforautomatedopticnervesheathmeasurement |