Cargando…

Novel Method to Obtain Contact Angles of Tumor Biopsies

[Image: see text] Characterizing the strength of a solid–liquid interface can be done by depositing a single drop of liquid on a planar solid surface and measuring the angle of the formed semicircle, called the contact angle. The contact angle of pure water is indicative of a surface’s hydrophobicit...

Descripción completa

Detalles Bibliográficos
Autores principales: Rincon, Julio, Kastellorizios, Michail
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10398839/
https://www.ncbi.nlm.nih.gov/pubmed/37546668
http://dx.doi.org/10.1021/acsomega.3c01792
_version_ 1785084114652626944
author Rincon, Julio
Kastellorizios, Michail
author_facet Rincon, Julio
Kastellorizios, Michail
author_sort Rincon, Julio
collection PubMed
description [Image: see text] Characterizing the strength of a solid–liquid interface can be done by depositing a single drop of liquid on a planar solid surface and measuring the angle of the formed semicircle, called the contact angle. The contact angle of pure water is indicative of a surface’s hydrophobicity and is a useful metric in biomedical applications such as tissue scaffolding and drug/tissue interactions. However, the roughness and inhomogeneity of most biological surfaces make obtaining accurate contact angles of such materials challenging. Here, we developed an instrument and methodology to obtain contact angles of tissue sections. Breast cancer tumor and nearby healthy tissue sections were used as the model biological surface. The custom instrument was built on existing equipment by improving drop dispensing accuracy in the nanoliter range, an XYZ stage, additional side view cameras, and microscope-based sample visualization. The method takes into account the inherent surface inhomogeneity and topology of tissue and the required method of illumination for contact angle acquisition. As such, the system uses an inverted microscope with a high sensitivity camera, an XYZ stage for accurate droplet placement on tissue, and multiple cameras to obtain contact angles around the entire perimeter of the drop. We tested the system with breast cancer biopsies and adjacent normal tissue from 75 patients and report here a trend of tumor exhibiting higher water contact angles, and thus higher hydrophobicity, compared to their respective normal adjacent tissue. The system described here can be used to characterize any type of biological tissue, which can be sectioned, with any liquid including water or solutions with dissolved or suspended therapeutic molecules and particles.
format Online
Article
Text
id pubmed-10398839
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-103988392023-08-04 Novel Method to Obtain Contact Angles of Tumor Biopsies Rincon, Julio Kastellorizios, Michail ACS Omega [Image: see text] Characterizing the strength of a solid–liquid interface can be done by depositing a single drop of liquid on a planar solid surface and measuring the angle of the formed semicircle, called the contact angle. The contact angle of pure water is indicative of a surface’s hydrophobicity and is a useful metric in biomedical applications such as tissue scaffolding and drug/tissue interactions. However, the roughness and inhomogeneity of most biological surfaces make obtaining accurate contact angles of such materials challenging. Here, we developed an instrument and methodology to obtain contact angles of tissue sections. Breast cancer tumor and nearby healthy tissue sections were used as the model biological surface. The custom instrument was built on existing equipment by improving drop dispensing accuracy in the nanoliter range, an XYZ stage, additional side view cameras, and microscope-based sample visualization. The method takes into account the inherent surface inhomogeneity and topology of tissue and the required method of illumination for contact angle acquisition. As such, the system uses an inverted microscope with a high sensitivity camera, an XYZ stage for accurate droplet placement on tissue, and multiple cameras to obtain contact angles around the entire perimeter of the drop. We tested the system with breast cancer biopsies and adjacent normal tissue from 75 patients and report here a trend of tumor exhibiting higher water contact angles, and thus higher hydrophobicity, compared to their respective normal adjacent tissue. The system described here can be used to characterize any type of biological tissue, which can be sectioned, with any liquid including water or solutions with dissolved or suspended therapeutic molecules and particles. American Chemical Society 2023-07-17 /pmc/articles/PMC10398839/ /pubmed/37546668 http://dx.doi.org/10.1021/acsomega.3c01792 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Rincon, Julio
Kastellorizios, Michail
Novel Method to Obtain Contact Angles of Tumor Biopsies
title Novel Method to Obtain Contact Angles of Tumor Biopsies
title_full Novel Method to Obtain Contact Angles of Tumor Biopsies
title_fullStr Novel Method to Obtain Contact Angles of Tumor Biopsies
title_full_unstemmed Novel Method to Obtain Contact Angles of Tumor Biopsies
title_short Novel Method to Obtain Contact Angles of Tumor Biopsies
title_sort novel method to obtain contact angles of tumor biopsies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10398839/
https://www.ncbi.nlm.nih.gov/pubmed/37546668
http://dx.doi.org/10.1021/acsomega.3c01792
work_keys_str_mv AT rinconjulio novelmethodtoobtaincontactanglesoftumorbiopsies
AT kastelloriziosmichail novelmethodtoobtaincontactanglesoftumorbiopsies