Cargando…

Preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral CT

BACKGROUND: The aim of this study was to explore application value of iodine concentration from dual-energy spectral computed tomography (DESCT) in preoperative prediction of lymphovascular tumor thrombus in patients with colorectal cancer (CRC). METHODS: We finally retrospectively analyzed 50 patie...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Xiang, Quan, Xin, Che, Xiao-ling, Xu, Lu-Lu, Yang, Chun-mei, Zhang, Xiao-di, Shu, Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10398985/
https://www.ncbi.nlm.nih.gov/pubmed/37537532
http://dx.doi.org/10.1186/s12880-023-01060-z
_version_ 1785084152504123392
author Yuan, Xiang
Quan, Xin
Che, Xiao-ling
Xu, Lu-Lu
Yang, Chun-mei
Zhang, Xiao-di
Shu, Jian
author_facet Yuan, Xiang
Quan, Xin
Che, Xiao-ling
Xu, Lu-Lu
Yang, Chun-mei
Zhang, Xiao-di
Shu, Jian
author_sort Yuan, Xiang
collection PubMed
description BACKGROUND: The aim of this study was to explore application value of iodine concentration from dual-energy spectral computed tomography (DESCT) in preoperative prediction of lymphovascular tumor thrombus in patients with colorectal cancer (CRC). METHODS: We finally retrospectively analyzed 50 patients with CRC who underwent abdominal DESCT before receiving any preoperative treatment and underwent surgery to obtain pathological specimens which were stained with hematoxylin-eosin (HE) staining. According to the presence of cancer cell nests in blood vessels and lymphatic vessels, the subjects were divided into the positive group and negative group of lymphovascular tumor thrombus. Two radiologists independently measured the normalized iodine concentration (NIC) values, effective atomic number (Zeff) and CT values of virtual monochromatic images (VMIs) at 40–90 keV of the primary tumors in the arterial phase (AP) and venous phase (VP). Used SPSS 17.0 to calculate the receiver operating characteristic (ROC) curve to evaluate diagnostic value. RESULTS: The patients were divided into lymphovascular tumor thrombus positive group(n = 16) and negative group(n = 34). The values of NIC-AP and NIC-VP in the positive group were 0.17 ± 0.09, 0.51 ± 0.13, respectively. And those in the negative group were 0.15 ± 0.06, 0.43 ± 0.12, respectively. There was significant difference in NIC-VP value between the two groups (p = 0.039), but there was no significant difference in NIC-AP value (p = 0.423). The optimal threshold value of NIC-VP value for diagnosis of lymphovascular tumor thrombus was 0.364. The sensitivity was 68.8% and the specificity was 67.6%. CONCLUSIONS: The NIC-VP value of DESCT can be used to predict the presence or absence of the lymphovascular tumor thrombus in CRC patients before operation, which is helpful to select the best treatment scheme and evaluate its prognosis.
format Online
Article
Text
id pubmed-10398985
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-103989852023-08-04 Preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral CT Yuan, Xiang Quan, Xin Che, Xiao-ling Xu, Lu-Lu Yang, Chun-mei Zhang, Xiao-di Shu, Jian BMC Med Imaging Research BACKGROUND: The aim of this study was to explore application value of iodine concentration from dual-energy spectral computed tomography (DESCT) in preoperative prediction of lymphovascular tumor thrombus in patients with colorectal cancer (CRC). METHODS: We finally retrospectively analyzed 50 patients with CRC who underwent abdominal DESCT before receiving any preoperative treatment and underwent surgery to obtain pathological specimens which were stained with hematoxylin-eosin (HE) staining. According to the presence of cancer cell nests in blood vessels and lymphatic vessels, the subjects were divided into the positive group and negative group of lymphovascular tumor thrombus. Two radiologists independently measured the normalized iodine concentration (NIC) values, effective atomic number (Zeff) and CT values of virtual monochromatic images (VMIs) at 40–90 keV of the primary tumors in the arterial phase (AP) and venous phase (VP). Used SPSS 17.0 to calculate the receiver operating characteristic (ROC) curve to evaluate diagnostic value. RESULTS: The patients were divided into lymphovascular tumor thrombus positive group(n = 16) and negative group(n = 34). The values of NIC-AP and NIC-VP in the positive group were 0.17 ± 0.09, 0.51 ± 0.13, respectively. And those in the negative group were 0.15 ± 0.06, 0.43 ± 0.12, respectively. There was significant difference in NIC-VP value between the two groups (p = 0.039), but there was no significant difference in NIC-AP value (p = 0.423). The optimal threshold value of NIC-VP value for diagnosis of lymphovascular tumor thrombus was 0.364. The sensitivity was 68.8% and the specificity was 67.6%. CONCLUSIONS: The NIC-VP value of DESCT can be used to predict the presence or absence of the lymphovascular tumor thrombus in CRC patients before operation, which is helpful to select the best treatment scheme and evaluate its prognosis. BioMed Central 2023-08-03 /pmc/articles/PMC10398985/ /pubmed/37537532 http://dx.doi.org/10.1186/s12880-023-01060-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Yuan, Xiang
Quan, Xin
Che, Xiao-ling
Xu, Lu-Lu
Yang, Chun-mei
Zhang, Xiao-di
Shu, Jian
Preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral CT
title Preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral CT
title_full Preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral CT
title_fullStr Preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral CT
title_full_unstemmed Preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral CT
title_short Preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral CT
title_sort preoperative prediction of the lymphovascular tumor thrombus of colorectal cancer with the iodine concentrations from dual-energy spectral ct
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10398985/
https://www.ncbi.nlm.nih.gov/pubmed/37537532
http://dx.doi.org/10.1186/s12880-023-01060-z
work_keys_str_mv AT yuanxiang preoperativepredictionofthelymphovasculartumorthrombusofcolorectalcancerwiththeiodineconcentrationsfromdualenergyspectralct
AT quanxin preoperativepredictionofthelymphovasculartumorthrombusofcolorectalcancerwiththeiodineconcentrationsfromdualenergyspectralct
AT chexiaoling preoperativepredictionofthelymphovasculartumorthrombusofcolorectalcancerwiththeiodineconcentrationsfromdualenergyspectralct
AT xululu preoperativepredictionofthelymphovasculartumorthrombusofcolorectalcancerwiththeiodineconcentrationsfromdualenergyspectralct
AT yangchunmei preoperativepredictionofthelymphovasculartumorthrombusofcolorectalcancerwiththeiodineconcentrationsfromdualenergyspectralct
AT zhangxiaodi preoperativepredictionofthelymphovasculartumorthrombusofcolorectalcancerwiththeiodineconcentrationsfromdualenergyspectralct
AT shujian preoperativepredictionofthelymphovasculartumorthrombusofcolorectalcancerwiththeiodineconcentrationsfromdualenergyspectralct