Cargando…

The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review

The Keller funnel (Allergan; AbbVie Inc, North Chicago, IL) is commonly used to insert breast implants as part of a “no touch” protocol. Many plastic surgeons believe that this device reduces the risk of capsular contracture. This review was undertaken to evaluate the evidence regarding any reductio...

Descripción completa

Detalles Bibliográficos
Autor principal: Swanson, Eric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10399935/
https://www.ncbi.nlm.nih.gov/pubmed/37347153
http://dx.doi.org/10.1097/SAP.0000000000003549
_version_ 1785084357231247360
author Swanson, Eric
author_facet Swanson, Eric
author_sort Swanson, Eric
collection PubMed
description The Keller funnel (Allergan; AbbVie Inc, North Chicago, IL) is commonly used to insert breast implants as part of a “no touch” protocol. Many plastic surgeons believe that this device reduces the risk of capsular contracture. This review was undertaken to evaluate the evidence regarding any reduction in capsular contracture rate, other possible benefits, safety and to investigate financial conflict of interest. METHODS: A PubMed electronic literature search was conducted to identify studies comparing capsular contracture rates with and without the Keller funnel. The Open Payments database was accessed for information regarding corporate payments to plastic surgeons. RESULTS: Two retrospective historical case-control studies, published in 2016 and 2018, were identified. Both studies had important confounders, including implant type and placement, which are known to affect capsular contracture rates. Major financial conflicts of interest were present. Most authors did not disclose these conflicts, which totaled more than $1 million and were usually categorized as gifts from Allergan, which purchased the Keller funnel in 2017. DISCUSSION: Financial conflict of interest, along with publication bias, creates a bias toward publication of positive findings. No reliable evidence supports a “no touch” technique, which is a misnomer because manual handling of implants is unavoidable, even when using a funnel. Recent microbiological studies do not support a specific bacterial etiology for capsular contracture. No evidence supports contamination by the surgeon touching the implant. Among other proposed benefits, such as reduced operating time, less contamination, a shorter incision, and less implant trauma, only a slightly shorter incision (1 cm) is supported by the evidence. The cost is $150 per funnel. CONCLUSIONS: No reliable evidence supports the use of a Keller funnel to reduce the risk of capsular contracture. Both supportive studies contain confounding variables, limited follow-up time, and no plausible scientific basis for efficacy. Institutional review board approval of studies on human subjects is not optional. Financial conflicts of interest are extraordinary in their magnitude and potential for creating undue influence. Greater transparency and honest disclosures are needed.
format Online
Article
Text
id pubmed-10399935
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-103999352023-08-04 The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review Swanson, Eric Ann Plast Surg Review Paper The Keller funnel (Allergan; AbbVie Inc, North Chicago, IL) is commonly used to insert breast implants as part of a “no touch” protocol. Many plastic surgeons believe that this device reduces the risk of capsular contracture. This review was undertaken to evaluate the evidence regarding any reduction in capsular contracture rate, other possible benefits, safety and to investigate financial conflict of interest. METHODS: A PubMed electronic literature search was conducted to identify studies comparing capsular contracture rates with and without the Keller funnel. The Open Payments database was accessed for information regarding corporate payments to plastic surgeons. RESULTS: Two retrospective historical case-control studies, published in 2016 and 2018, were identified. Both studies had important confounders, including implant type and placement, which are known to affect capsular contracture rates. Major financial conflicts of interest were present. Most authors did not disclose these conflicts, which totaled more than $1 million and were usually categorized as gifts from Allergan, which purchased the Keller funnel in 2017. DISCUSSION: Financial conflict of interest, along with publication bias, creates a bias toward publication of positive findings. No reliable evidence supports a “no touch” technique, which is a misnomer because manual handling of implants is unavoidable, even when using a funnel. Recent microbiological studies do not support a specific bacterial etiology for capsular contracture. No evidence supports contamination by the surgeon touching the implant. Among other proposed benefits, such as reduced operating time, less contamination, a shorter incision, and less implant trauma, only a slightly shorter incision (1 cm) is supported by the evidence. The cost is $150 per funnel. CONCLUSIONS: No reliable evidence supports the use of a Keller funnel to reduce the risk of capsular contracture. Both supportive studies contain confounding variables, limited follow-up time, and no plausible scientific basis for efficacy. Institutional review board approval of studies on human subjects is not optional. Financial conflicts of interest are extraordinary in their magnitude and potential for creating undue influence. Greater transparency and honest disclosures are needed. Lippincott Williams & Wilkins 2023-08 2023-06-01 /pmc/articles/PMC10399935/ /pubmed/37347153 http://dx.doi.org/10.1097/SAP.0000000000003549 Text en Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Review Paper
Swanson, Eric
The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review
title The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review
title_full The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review
title_fullStr The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review
title_full_unstemmed The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review
title_short The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review
title_sort keller funnel, capsular contracture, and conflict of interest: a review
topic Review Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10399935/
https://www.ncbi.nlm.nih.gov/pubmed/37347153
http://dx.doi.org/10.1097/SAP.0000000000003549
work_keys_str_mv AT swansoneric thekellerfunnelcapsularcontractureandconflictofinterestareview
AT swansoneric kellerfunnelcapsularcontractureandconflictofinterestareview