Cargando…

Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma

PURPOSE: The aim this study is to determine anterior chamber parameters variations induced by PreserFlo MicroShunt implantation, in the early post-operative days. METHODS: This is a prospective observational study on 48 eyes undergoing PreserFlo MicroShunt implantation alone (n = 30) or combined wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Gambini, Gloria, Carlà, Matteo Mario, Giannuzzi, Federico, Boselli, Francesco, Crincoli, Emanuele, Caporossi, Tomaso, Baldascino, Antonio, De Vico, Umberto, Savastano, Alfonso, Rizzo, Stanislao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10400679/
https://www.ncbi.nlm.nih.gov/pubmed/37031312
http://dx.doi.org/10.1007/s10792-023-02697-z
_version_ 1785084497419567104
author Gambini, Gloria
Carlà, Matteo Mario
Giannuzzi, Federico
Boselli, Francesco
Crincoli, Emanuele
Caporossi, Tomaso
Baldascino, Antonio
De Vico, Umberto
Savastano, Alfonso
Rizzo, Stanislao
author_facet Gambini, Gloria
Carlà, Matteo Mario
Giannuzzi, Federico
Boselli, Francesco
Crincoli, Emanuele
Caporossi, Tomaso
Baldascino, Antonio
De Vico, Umberto
Savastano, Alfonso
Rizzo, Stanislao
author_sort Gambini, Gloria
collection PubMed
description PURPOSE: The aim this study is to determine anterior chamber parameters variations induced by PreserFlo MicroShunt implantation, in the early post-operative days. METHODS: This is a prospective observational study on 48 eyes undergoing PreserFlo MicroShunt implantation alone (n = 30) or combined with phacoemulsification (n = 18). Anterior chamber depth (ACD) and volume (ACV), central corneal thickness (CCT) and total corneal astigmatism (TCA) were evaluated pre-operatively, post-operatively at day-1 and at 1 week with the Pentacam tomography. RESULTS: Intraocular pressure decreased significantly from 20.9 ± 4.0 to 8.0 ± 2.8 mmHg (p < 0.0001) and to 10.8 ± 3.7 mmHg (p = 0.0001) at day-1 and week-1, respectively. TCA varied significantly from baseline (1.5 ± 1.2 D) to both day 1 follow up (2.7 ± 1.9 D, p = 0.0003) and week 1 follow up (2.2 ± 1.6 D, p = 0.02). Nevertheless, only K1 showed a transient flattening at day 1, while K2 value didn’t show any statistical variation in the early post-operative period. CCT value rose significantly at day 1 (547 ± 49 vs. 529 ± 32 µm at baseline, p = 0.04), but then returned toward pre-operative values at week 1 (537 ± 39 µm, p = 0.57). In contrast, ACD values changed insignificantly from 3.3 ± 0.9 to 3.7 ± 1.0 mm at day 1 (p = 0.21), and then stabilized at 3.4 ± 0.9 mm (p = 0.82) at week 1 follow up. ACV changed from 150.0 ± 36.2 to 159.5 ± 42.1 mm(3) at day 1 (p = 0.58), and successively to 153.9 ± 37.9 mm(3) at week 1 follow up (p = 0.96). The subgroup analysis in eyes undergoing standalone PreserFlo implantation didn’t show significant changes in both ACD and ACV. CONCLUSION: PreserFlo implantation minimizes the anterior chamber modifications generated by traditional filtering surgery, inducing low and transient corneal and biometric changes only in the very early postoperative period and insignificant changes to ACD and ACV, label of its safety and minimal invasiveness.
format Online
Article
Text
id pubmed-10400679
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-104006792023-08-05 Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma Gambini, Gloria Carlà, Matteo Mario Giannuzzi, Federico Boselli, Francesco Crincoli, Emanuele Caporossi, Tomaso Baldascino, Antonio De Vico, Umberto Savastano, Alfonso Rizzo, Stanislao Int Ophthalmol Original Paper PURPOSE: The aim this study is to determine anterior chamber parameters variations induced by PreserFlo MicroShunt implantation, in the early post-operative days. METHODS: This is a prospective observational study on 48 eyes undergoing PreserFlo MicroShunt implantation alone (n = 30) or combined with phacoemulsification (n = 18). Anterior chamber depth (ACD) and volume (ACV), central corneal thickness (CCT) and total corneal astigmatism (TCA) were evaluated pre-operatively, post-operatively at day-1 and at 1 week with the Pentacam tomography. RESULTS: Intraocular pressure decreased significantly from 20.9 ± 4.0 to 8.0 ± 2.8 mmHg (p < 0.0001) and to 10.8 ± 3.7 mmHg (p = 0.0001) at day-1 and week-1, respectively. TCA varied significantly from baseline (1.5 ± 1.2 D) to both day 1 follow up (2.7 ± 1.9 D, p = 0.0003) and week 1 follow up (2.2 ± 1.6 D, p = 0.02). Nevertheless, only K1 showed a transient flattening at day 1, while K2 value didn’t show any statistical variation in the early post-operative period. CCT value rose significantly at day 1 (547 ± 49 vs. 529 ± 32 µm at baseline, p = 0.04), but then returned toward pre-operative values at week 1 (537 ± 39 µm, p = 0.57). In contrast, ACD values changed insignificantly from 3.3 ± 0.9 to 3.7 ± 1.0 mm at day 1 (p = 0.21), and then stabilized at 3.4 ± 0.9 mm (p = 0.82) at week 1 follow up. ACV changed from 150.0 ± 36.2 to 159.5 ± 42.1 mm(3) at day 1 (p = 0.58), and successively to 153.9 ± 37.9 mm(3) at week 1 follow up (p = 0.96). The subgroup analysis in eyes undergoing standalone PreserFlo implantation didn’t show significant changes in both ACD and ACV. CONCLUSION: PreserFlo implantation minimizes the anterior chamber modifications generated by traditional filtering surgery, inducing low and transient corneal and biometric changes only in the very early postoperative period and insignificant changes to ACD and ACV, label of its safety and minimal invasiveness. Springer Netherlands 2023-04-08 2023 /pmc/articles/PMC10400679/ /pubmed/37031312 http://dx.doi.org/10.1007/s10792-023-02697-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Paper
Gambini, Gloria
Carlà, Matteo Mario
Giannuzzi, Federico
Boselli, Francesco
Crincoli, Emanuele
Caporossi, Tomaso
Baldascino, Antonio
De Vico, Umberto
Savastano, Alfonso
Rizzo, Stanislao
Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma
title Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma
title_full Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma
title_fullStr Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma
title_full_unstemmed Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma
title_short Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma
title_sort early post-operative anterior segment parameters modifications induced by preserflo microshunt in primary open-angle glaucoma
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10400679/
https://www.ncbi.nlm.nih.gov/pubmed/37031312
http://dx.doi.org/10.1007/s10792-023-02697-z
work_keys_str_mv AT gambinigloria earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT carlamatteomario earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT giannuzzifederico earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT bosellifrancesco earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT crincoliemanuele earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT caporossitomaso earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT baldascinoantonio earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT devicoumberto earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT savastanoalfonso earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma
AT rizzostanislao earlypostoperativeanteriorsegmentparametersmodificationsinducedbypreserflomicroshuntinprimaryopenangleglaucoma