Cargando…
Morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine
PURPOSE: Heat-induced destruction of cancer cells via microwave ablation (MWA) is emerging as a viable treatment of primary and metastatic liver cancer. Prediction of the impacted zone where cell death occurs, especially in the presence of vasculature, is challenging but may be achieved via biophysi...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10403086/ https://www.ncbi.nlm.nih.gov/pubmed/37540658 http://dx.doi.org/10.1371/journal.pone.0289674 |
_version_ | 1785084987874213888 |
---|---|
author | Varble, Nicole A. Bakhutashvili, Ivane Reed, Sheridan L. Delgado, Jose Tokoutsi, Zoi Frackowiak, Bruno Baragona, Marco Karanian, John W. Wood, Bradford J. Pritchard, William F. |
author_facet | Varble, Nicole A. Bakhutashvili, Ivane Reed, Sheridan L. Delgado, Jose Tokoutsi, Zoi Frackowiak, Bruno Baragona, Marco Karanian, John W. Wood, Bradford J. Pritchard, William F. |
author_sort | Varble, Nicole A. |
collection | PubMed |
description | PURPOSE: Heat-induced destruction of cancer cells via microwave ablation (MWA) is emerging as a viable treatment of primary and metastatic liver cancer. Prediction of the impacted zone where cell death occurs, especially in the presence of vasculature, is challenging but may be achieved via biophysical modeling. To advance and characterize thermal MWA for focal cancer treatment, an in vivo method and experimental dataset were created for assessment of biophysical models designed to dynamically predict ablation zone parameters, given the delivery device, power, location, and proximity to vessels. MATERIALS AND METHODS: MWA zone size, shape, and temperature were characterized and monitored in the absence of perfusion in ex vivo liver and a tissue-mimicking thermochromic phantom (TMTCP) at two power settings. Temperature was monitored over time using implanted thermocouples with their locations defined by CT. TMTCPs were used to identify the location of the ablation zone relative to the probe. In 6 swine, contrast-enhanced CTs were additionally acquired to visualize vasculature and absence of perfusion along with corresponding post-mortem gross pathology. RESULTS: Bench studies demonstrated average ablation zone sizes of 4.13±1.56cm(2) and 8.51±3.92cm(2), solidity of 0.96±0.06 and 0.99±0.01, ablations centered 3.75cm and 3.5cm proximal to the probe tip, and temperatures of 50 ºC at 14.5±13.4s and 2.5±2.1s for 40W and 90W ablations, respectively. In vivo imaging showed average volumes of 9.8±4.8cm(3) and 33.2±28.4cm(3) and 3D solidity of 0.87±0.02 and 0.75±0.15, and gross pathology showed a hemorrhagic halo area of 3.1±1.2cm(2) and 9.1±3.0cm(2) for 40W and 90W ablations, respectfully. Temperatures reached 50ºC at 19.5±9.2s and 13.0±8.3s for 40W and 90W ablations, respectively. CONCLUSION: MWA results are challenging to predict and are more variable than manufacturer-provided and bench predictions due to vascular stasis, heat-induced tissue changes, and probe operating conditions. Accurate prediction of MWA zones and temperature in vivo requires comprehensive thermal validation sets. |
format | Online Article Text |
id | pubmed-10403086 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-104030862023-08-05 Morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine Varble, Nicole A. Bakhutashvili, Ivane Reed, Sheridan L. Delgado, Jose Tokoutsi, Zoi Frackowiak, Bruno Baragona, Marco Karanian, John W. Wood, Bradford J. Pritchard, William F. PLoS One Research Article PURPOSE: Heat-induced destruction of cancer cells via microwave ablation (MWA) is emerging as a viable treatment of primary and metastatic liver cancer. Prediction of the impacted zone where cell death occurs, especially in the presence of vasculature, is challenging but may be achieved via biophysical modeling. To advance and characterize thermal MWA for focal cancer treatment, an in vivo method and experimental dataset were created for assessment of biophysical models designed to dynamically predict ablation zone parameters, given the delivery device, power, location, and proximity to vessels. MATERIALS AND METHODS: MWA zone size, shape, and temperature were characterized and monitored in the absence of perfusion in ex vivo liver and a tissue-mimicking thermochromic phantom (TMTCP) at two power settings. Temperature was monitored over time using implanted thermocouples with their locations defined by CT. TMTCPs were used to identify the location of the ablation zone relative to the probe. In 6 swine, contrast-enhanced CTs were additionally acquired to visualize vasculature and absence of perfusion along with corresponding post-mortem gross pathology. RESULTS: Bench studies demonstrated average ablation zone sizes of 4.13±1.56cm(2) and 8.51±3.92cm(2), solidity of 0.96±0.06 and 0.99±0.01, ablations centered 3.75cm and 3.5cm proximal to the probe tip, and temperatures of 50 ºC at 14.5±13.4s and 2.5±2.1s for 40W and 90W ablations, respectively. In vivo imaging showed average volumes of 9.8±4.8cm(3) and 33.2±28.4cm(3) and 3D solidity of 0.87±0.02 and 0.75±0.15, and gross pathology showed a hemorrhagic halo area of 3.1±1.2cm(2) and 9.1±3.0cm(2) for 40W and 90W ablations, respectfully. Temperatures reached 50ºC at 19.5±9.2s and 13.0±8.3s for 40W and 90W ablations, respectively. CONCLUSION: MWA results are challenging to predict and are more variable than manufacturer-provided and bench predictions due to vascular stasis, heat-induced tissue changes, and probe operating conditions. Accurate prediction of MWA zones and temperature in vivo requires comprehensive thermal validation sets. Public Library of Science 2023-08-04 /pmc/articles/PMC10403086/ /pubmed/37540658 http://dx.doi.org/10.1371/journal.pone.0289674 Text en https://creativecommons.org/publicdomain/zero/1.0/This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 (https://creativecommons.org/publicdomain/zero/1.0/) public domain dedication. |
spellingShingle | Research Article Varble, Nicole A. Bakhutashvili, Ivane Reed, Sheridan L. Delgado, Jose Tokoutsi, Zoi Frackowiak, Bruno Baragona, Marco Karanian, John W. Wood, Bradford J. Pritchard, William F. Morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine |
title | Morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine |
title_full | Morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine |
title_fullStr | Morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine |
title_full_unstemmed | Morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine |
title_short | Morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine |
title_sort | morphometric characterization and temporal temperature measurements during hepatic microwave ablation in swine |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10403086/ https://www.ncbi.nlm.nih.gov/pubmed/37540658 http://dx.doi.org/10.1371/journal.pone.0289674 |
work_keys_str_mv | AT varblenicolea morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT bakhutashviliivane morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT reedsheridanl morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT delgadojose morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT tokoutsizoi morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT frackowiakbruno morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT baragonamarco morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT karanianjohnw morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT woodbradfordj morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine AT pritchardwilliamf morphometriccharacterizationandtemporaltemperaturemeasurementsduringhepaticmicrowaveablationinswine |