Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis

Over the last few years, portable Near-Infrared Spectroscopy (NIRS) technology has been suggested for determining metabolic/ventilator thresholds. This systematic review and meta-analysis aimed to assess the reliability of a portable muscle oxygenation monitor for determining thresholds during exerc...

Descripción completa

Detalles Bibliográficos
Autores principales: Sendra-Pérez, Carlos, Sanchez-Jimenez, Jose Luis, Marzano-Felisatti, Joaquín Martín, Encarnación-Martínez, Alberto, Salvador-Palmer, Rosario, Priego-Quesada, Jose I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10403529/
https://www.ncbi.nlm.nih.gov/pubmed/37542055
http://dx.doi.org/10.1038/s41598-023-39651-z
_version_ 1785085087439650816
author Sendra-Pérez, Carlos
Sanchez-Jimenez, Jose Luis
Marzano-Felisatti, Joaquín Martín
Encarnación-Martínez, Alberto
Salvador-Palmer, Rosario
Priego-Quesada, Jose I.
author_facet Sendra-Pérez, Carlos
Sanchez-Jimenez, Jose Luis
Marzano-Felisatti, Joaquín Martín
Encarnación-Martínez, Alberto
Salvador-Palmer, Rosario
Priego-Quesada, Jose I.
author_sort Sendra-Pérez, Carlos
collection PubMed
description Over the last few years, portable Near-Infrared Spectroscopy (NIRS) technology has been suggested for determining metabolic/ventilator thresholds. This systematic review and meta-analysis aimed to assess the reliability of a portable muscle oxygenation monitor for determining thresholds during exercise testing. The proposed PICO question was: Is the exercise intensity of muscle oxygenation thresholds, using portable NIRS, reliable compared with lactate and ventilatory thresholds for exercise intensity determined in athletes? A search of Pubmed, Scopus and Web of Science was undertaken and the review was conducted following PRISMA guidelines. Fifteen articles were included. The domains which presented the highest biases were confounders (93% with moderate or high risk) and participant selection (100% with moderate or high risk). The intra-class correlation coefficient between exercise intensity of the first ventilatory or lactate threshold and the first muscle oxygenation threshold was 0.53 (obtained with data from only 3 studies), whereas the second threshold was 0.80. The present work shows that although a portable muscle oxygenation monitor has moderate to good reliability for determining the second ventilatory and lactate thresholds, further research is necessary to investigate the mathematical methods of detection, the capacity to detect the first threshold, the detection in multiple regions, and the effect of sex, performance level and adipose tissue in determining thresholds.
format Online
Article
Text
id pubmed-10403529
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-104035292023-08-06 Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis Sendra-Pérez, Carlos Sanchez-Jimenez, Jose Luis Marzano-Felisatti, Joaquín Martín Encarnación-Martínez, Alberto Salvador-Palmer, Rosario Priego-Quesada, Jose I. Sci Rep Article Over the last few years, portable Near-Infrared Spectroscopy (NIRS) technology has been suggested for determining metabolic/ventilator thresholds. This systematic review and meta-analysis aimed to assess the reliability of a portable muscle oxygenation monitor for determining thresholds during exercise testing. The proposed PICO question was: Is the exercise intensity of muscle oxygenation thresholds, using portable NIRS, reliable compared with lactate and ventilatory thresholds for exercise intensity determined in athletes? A search of Pubmed, Scopus and Web of Science was undertaken and the review was conducted following PRISMA guidelines. Fifteen articles were included. The domains which presented the highest biases were confounders (93% with moderate or high risk) and participant selection (100% with moderate or high risk). The intra-class correlation coefficient between exercise intensity of the first ventilatory or lactate threshold and the first muscle oxygenation threshold was 0.53 (obtained with data from only 3 studies), whereas the second threshold was 0.80. The present work shows that although a portable muscle oxygenation monitor has moderate to good reliability for determining the second ventilatory and lactate thresholds, further research is necessary to investigate the mathematical methods of detection, the capacity to detect the first threshold, the detection in multiple regions, and the effect of sex, performance level and adipose tissue in determining thresholds. Nature Publishing Group UK 2023-08-04 /pmc/articles/PMC10403529/ /pubmed/37542055 http://dx.doi.org/10.1038/s41598-023-39651-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Sendra-Pérez, Carlos
Sanchez-Jimenez, Jose Luis
Marzano-Felisatti, Joaquín Martín
Encarnación-Martínez, Alberto
Salvador-Palmer, Rosario
Priego-Quesada, Jose I.
Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis
title Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis
title_full Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis
title_fullStr Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis
title_full_unstemmed Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis
title_short Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis
title_sort reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10403529/
https://www.ncbi.nlm.nih.gov/pubmed/37542055
http://dx.doi.org/10.1038/s41598-023-39651-z
work_keys_str_mv AT sendraperezcarlos reliabilityofthresholddeterminationusingportablemuscleoxygenationmonitorsduringexercisetestingasystematicreviewandmetaanalysis
AT sanchezjimenezjoseluis reliabilityofthresholddeterminationusingportablemuscleoxygenationmonitorsduringexercisetestingasystematicreviewandmetaanalysis
AT marzanofelisattijoaquinmartin reliabilityofthresholddeterminationusingportablemuscleoxygenationmonitorsduringexercisetestingasystematicreviewandmetaanalysis
AT encarnacionmartinezalberto reliabilityofthresholddeterminationusingportablemuscleoxygenationmonitorsduringexercisetestingasystematicreviewandmetaanalysis
AT salvadorpalmerrosario reliabilityofthresholddeterminationusingportablemuscleoxygenationmonitorsduringexercisetestingasystematicreviewandmetaanalysis
AT priegoquesadajosei reliabilityofthresholddeterminationusingportablemuscleoxygenationmonitorsduringexercisetestingasystematicreviewandmetaanalysis