Cargando…

Comparison of the Haemodynamic Performance of Various Treatment Options for Aorto-Iliac Occlusive Disease

INTRODUCTION: Several surgical and endovascular techniques are used during the treatment of aorto-iliac occlusive disease. Aortobifemoral bypass (AoBFB) is the standard of care, but other options such as axillobifemoral (AxBFB) bypass, aorto-iliac kissing stents (KS), and covered endovascular recons...

Descripción completa

Detalles Bibliográficos
Autores principales: Kontopodis, Nikolaos, Tzirakis, Konstantinos, Tzartzalou, Ifigeneia, Ioannou, Christos V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10403718/
https://www.ncbi.nlm.nih.gov/pubmed/37547924
http://dx.doi.org/10.1016/j.ejvsvf.2023.07.001
_version_ 1785085132759105536
author Kontopodis, Nikolaos
Tzirakis, Konstantinos
Tzartzalou, Ifigeneia
Ioannou, Christos V.
author_facet Kontopodis, Nikolaos
Tzirakis, Konstantinos
Tzartzalou, Ifigeneia
Ioannou, Christos V.
author_sort Kontopodis, Nikolaos
collection PubMed
description INTRODUCTION: Several surgical and endovascular techniques are used during the treatment of aorto-iliac occlusive disease. Aortobifemoral bypass (AoBFB) is the standard of care, but other options such as axillobifemoral (AxBFB) bypass, aorto-iliac kissing stents (KS), and covered endovascular reconstruction of aortic bifurcation (CERAB) are also available. This study aimed to perform a computational comparison of these four modalities to investigate their haemodynamic performance. REPORT: Eight patient specific anatomies were analysed, with each of the abovementioned techniques used to treat two anatomies. The CT angiograms were segmented from the renal (or axillary) to common femoral arteries and the 3D geometries were exported. A commercial finite volume solver was implemented for numerical simulations. Outcomes that were assessed were pressure drop (ΔP) between the inlet and the outlet for every configuration and haemodynamic indices of Time Average Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI), and Relative Residence Time (RRT) as markers of a thrombogenic environment. The results indicate that maximum ΔP was observed at peak systole for all models, with values ranging between 12 mmHg and 21 mmHg for the AoBFB, 64 mmHg and 96 mmHg for the AxBFB, 31 mmHg and 46 mmHg for the KS, and 43 mmHg and 46 mmHg for the CERAB configuration. TAWSS, OSI, and RRT varied among different configurations, mostly presenting values well above thrombogenic thresholds. Regarding RRT, the percentage of total surface area presenting such values is 2.5%, 3.2%, 2%, and 4.3% for the AoBFB, AxBFB, KS, and CERAB configurations, respectively. DISCUSSION: Computational modelling indicates a favourable haemodynamic performance of AoBFB compared with the other configurations. This leads to a smaller pressure drop and sconsequently a higher pressure in the outlet of the conduit, which is the perfusion pressure of the limb. Notably, lower patency rates of the latter modalities cannot be explained based on haemodynamic indices.
format Online
Article
Text
id pubmed-10403718
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104037182023-08-06 Comparison of the Haemodynamic Performance of Various Treatment Options for Aorto-Iliac Occlusive Disease Kontopodis, Nikolaos Tzirakis, Konstantinos Tzartzalou, Ifigeneia Ioannou, Christos V. EJVES Vasc Forum Short Report INTRODUCTION: Several surgical and endovascular techniques are used during the treatment of aorto-iliac occlusive disease. Aortobifemoral bypass (AoBFB) is the standard of care, but other options such as axillobifemoral (AxBFB) bypass, aorto-iliac kissing stents (KS), and covered endovascular reconstruction of aortic bifurcation (CERAB) are also available. This study aimed to perform a computational comparison of these four modalities to investigate their haemodynamic performance. REPORT: Eight patient specific anatomies were analysed, with each of the abovementioned techniques used to treat two anatomies. The CT angiograms were segmented from the renal (or axillary) to common femoral arteries and the 3D geometries were exported. A commercial finite volume solver was implemented for numerical simulations. Outcomes that were assessed were pressure drop (ΔP) between the inlet and the outlet for every configuration and haemodynamic indices of Time Average Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI), and Relative Residence Time (RRT) as markers of a thrombogenic environment. The results indicate that maximum ΔP was observed at peak systole for all models, with values ranging between 12 mmHg and 21 mmHg for the AoBFB, 64 mmHg and 96 mmHg for the AxBFB, 31 mmHg and 46 mmHg for the KS, and 43 mmHg and 46 mmHg for the CERAB configuration. TAWSS, OSI, and RRT varied among different configurations, mostly presenting values well above thrombogenic thresholds. Regarding RRT, the percentage of total surface area presenting such values is 2.5%, 3.2%, 2%, and 4.3% for the AoBFB, AxBFB, KS, and CERAB configurations, respectively. DISCUSSION: Computational modelling indicates a favourable haemodynamic performance of AoBFB compared with the other configurations. This leads to a smaller pressure drop and sconsequently a higher pressure in the outlet of the conduit, which is the perfusion pressure of the limb. Notably, lower patency rates of the latter modalities cannot be explained based on haemodynamic indices. Elsevier 2023-07-12 /pmc/articles/PMC10403718/ /pubmed/37547924 http://dx.doi.org/10.1016/j.ejvsvf.2023.07.001 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Short Report
Kontopodis, Nikolaos
Tzirakis, Konstantinos
Tzartzalou, Ifigeneia
Ioannou, Christos V.
Comparison of the Haemodynamic Performance of Various Treatment Options for Aorto-Iliac Occlusive Disease
title Comparison of the Haemodynamic Performance of Various Treatment Options for Aorto-Iliac Occlusive Disease
title_full Comparison of the Haemodynamic Performance of Various Treatment Options for Aorto-Iliac Occlusive Disease
title_fullStr Comparison of the Haemodynamic Performance of Various Treatment Options for Aorto-Iliac Occlusive Disease
title_full_unstemmed Comparison of the Haemodynamic Performance of Various Treatment Options for Aorto-Iliac Occlusive Disease
title_short Comparison of the Haemodynamic Performance of Various Treatment Options for Aorto-Iliac Occlusive Disease
title_sort comparison of the haemodynamic performance of various treatment options for aorto-iliac occlusive disease
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10403718/
https://www.ncbi.nlm.nih.gov/pubmed/37547924
http://dx.doi.org/10.1016/j.ejvsvf.2023.07.001
work_keys_str_mv AT kontopodisnikolaos comparisonofthehaemodynamicperformanceofvarioustreatmentoptionsforaortoiliacocclusivedisease
AT tzirakiskonstantinos comparisonofthehaemodynamicperformanceofvarioustreatmentoptionsforaortoiliacocclusivedisease
AT tzartzalouifigeneia comparisonofthehaemodynamicperformanceofvarioustreatmentoptionsforaortoiliacocclusivedisease
AT ioannouchristosv comparisonofthehaemodynamicperformanceofvarioustreatmentoptionsforaortoiliacocclusivedisease