Cargando…
Comment on “Ultrasonographic scores for ileal Crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?”
We read with interest the study by Freitas et al. comparing contrast-enhanced ultrasound (CEUS) and parameters from a time-intensity curve (TIC) with the SUS-CD score and IBUS-SAS score in patients with Crohn’s disease (CD) undergoing gastrointestinal ultrasound (GIUS) and ileocolonoscopy. The aim w...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10403931/ https://www.ncbi.nlm.nih.gov/pubmed/37542237 http://dx.doi.org/10.1186/s12876-023-02882-5 |
_version_ | 1785085183416860672 |
---|---|
author | Nylund, Kim Novak, Kerri Wilkens, Rune |
author_facet | Nylund, Kim Novak, Kerri Wilkens, Rune |
author_sort | Nylund, Kim |
collection | PubMed |
description | We read with interest the study by Freitas et al. comparing contrast-enhanced ultrasound (CEUS) and parameters from a time-intensity curve (TIC) with the SUS-CD score and IBUS-SAS score in patients with Crohn’s disease (CD) undergoing gastrointestinal ultrasound (GIUS) and ileocolonoscopy. The aim was to compare the accuracy of CEUS and aforementioned scores in predicting terminal ileal inflammatory activity in patients with CD. In this retrospective study of 50 patients, inflammatory activity was defined as a segmental score of SES-CD ≥ 7 in the terminal ileum. The study found 30 patients with active endoscopic disease demonstrating no significant difference between the “inactive” and “active” SUS CD and IBUS-SAS scores. However, the CEUS peak enhancement derived from the TIC was shown to be significantly different. The authors conclude CEUS was superior for detecting inflammation in the terminal ileum, as opposed to ultrasound scores relying on bowel wall thickness and color Doppler. |
format | Online Article Text |
id | pubmed-10403931 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-104039312023-08-06 Comment on “Ultrasonographic scores for ileal Crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?” Nylund, Kim Novak, Kerri Wilkens, Rune BMC Gastroenterol Matters Arising We read with interest the study by Freitas et al. comparing contrast-enhanced ultrasound (CEUS) and parameters from a time-intensity curve (TIC) with the SUS-CD score and IBUS-SAS score in patients with Crohn’s disease (CD) undergoing gastrointestinal ultrasound (GIUS) and ileocolonoscopy. The aim was to compare the accuracy of CEUS and aforementioned scores in predicting terminal ileal inflammatory activity in patients with CD. In this retrospective study of 50 patients, inflammatory activity was defined as a segmental score of SES-CD ≥ 7 in the terminal ileum. The study found 30 patients with active endoscopic disease demonstrating no significant difference between the “inactive” and “active” SUS CD and IBUS-SAS scores. However, the CEUS peak enhancement derived from the TIC was shown to be significantly different. The authors conclude CEUS was superior for detecting inflammation in the terminal ileum, as opposed to ultrasound scores relying on bowel wall thickness and color Doppler. BioMed Central 2023-08-05 /pmc/articles/PMC10403931/ /pubmed/37542237 http://dx.doi.org/10.1186/s12876-023-02882-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Matters Arising Nylund, Kim Novak, Kerri Wilkens, Rune Comment on “Ultrasonographic scores for ileal Crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?” |
title | Comment on “Ultrasonographic scores for ileal Crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?” |
title_full | Comment on “Ultrasonographic scores for ileal Crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?” |
title_fullStr | Comment on “Ultrasonographic scores for ileal Crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?” |
title_full_unstemmed | Comment on “Ultrasonographic scores for ileal Crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?” |
title_short | Comment on “Ultrasonographic scores for ileal Crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?” |
title_sort | comment on “ultrasonographic scores for ileal crohn’s disease assessment: better, worse or the same as contrast‑enhanced ultrasound?” |
topic | Matters Arising |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10403931/ https://www.ncbi.nlm.nih.gov/pubmed/37542237 http://dx.doi.org/10.1186/s12876-023-02882-5 |
work_keys_str_mv | AT nylundkim commentonultrasonographicscoresforilealcrohnsdiseaseassessmentbetterworseorthesameascontrastenhancedultrasound AT novakkerri commentonultrasonographicscoresforilealcrohnsdiseaseassessmentbetterworseorthesameascontrastenhancedultrasound AT wilkensrune commentonultrasonographicscoresforilealcrohnsdiseaseassessmentbetterworseorthesameascontrastenhancedultrasound |