Cargando…
Screening bisphenols in complex samples via a planar Arxula adeninivorans bioluminescence bioassay
The Arxula yeast bisphenol screen (A-YBS) utilizes the bioluminescent Arxula adeninivorans yeast–based reporter cells for tailored analysis of bisphenols, one of the major endocrine-disrupting compound groups. For the first time, this bioreporter has been applied on the high-performance thin-layer c...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404207/ https://www.ncbi.nlm.nih.gov/pubmed/37458782 http://dx.doi.org/10.1007/s00216-023-04820-6 |
_version_ | 1785085246378606592 |
---|---|
author | Jaber, Max Jähne, Martin Oberle, Michaela Morlock, Gertrud E. |
author_facet | Jaber, Max Jähne, Martin Oberle, Michaela Morlock, Gertrud E. |
author_sort | Jaber, Max |
collection | PubMed |
description | The Arxula yeast bisphenol screen (A-YBS) utilizes the bioluminescent Arxula adeninivorans yeast–based reporter cells for tailored analysis of bisphenols, one of the major endocrine-disrupting compound groups. For the first time, this bioreporter has been applied on the high-performance thin-layer chromatography (HPTLC) adsorbent surface to develop a respective planar bioluminescence bioassay (pA-YBS). The goal was to combine the advantages of HPTLC with a more selective bioassay detection for bisphenols. The performance of this pA-YBS bioluminescence bioassay was demonstrated by calculating the half-maximal effective concentration (EC(50)) of bisphenols compared to references. The EC(50) ranged from 267 pg/band for bisphenol Z and 322 pg/band for bisphenol A (BPA) to > 1 ng/band for other bisphenols (BPC, BPE, BPF, and BPS) and references (17β-estradiol and 17α-ethinylestradiol). The EC(50) value of BPA was three times more sensitive in signal detection than that of 17β-estradiol. The visual or videodensitometric limit of detection of BPA was about 200 pg/zone. The higher signal intensity and sensitivity for BPA confirmed the tailored bioassay selectivity compared to the existing estrogen screen bioassay. It worked on different types of HPTLC silica gel plates. This HPTLC–UV/Vis/FLD–pA-YBS bioluminescence bioassay method was used to analyze complex mixtures such as six tin can migrates, five thermal papers, and eleven botanicals. The detected estrogenic compound zones in the tin can migrates were successfully verified via the duplex planar yeast antagonist estrogen screen (pYAES) bioassay. The two bisphenols A and S were identified in one out of five thermal papers and confirmed with high-resolution mass spectrometry. No bisphenols were detected in the botanicals investigated via the pA-YBS bioluminescence bioassay. However, the botanicals proved to contain phytoestrogens as detected via the pYAES bioassay, which confirmed the tailored bioassay selectivity. This HPTLC–UV/Vis/FLD–pA-YBS bioluminescence bioassay is suited for cost-efficient analysis of BPA in complex samples, with no need for sterile conditions due to the fast workflow. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04820-6. |
format | Online Article Text |
id | pubmed-10404207 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-104042072023-08-07 Screening bisphenols in complex samples via a planar Arxula adeninivorans bioluminescence bioassay Jaber, Max Jähne, Martin Oberle, Michaela Morlock, Gertrud E. Anal Bioanal Chem Research Paper The Arxula yeast bisphenol screen (A-YBS) utilizes the bioluminescent Arxula adeninivorans yeast–based reporter cells for tailored analysis of bisphenols, one of the major endocrine-disrupting compound groups. For the first time, this bioreporter has been applied on the high-performance thin-layer chromatography (HPTLC) adsorbent surface to develop a respective planar bioluminescence bioassay (pA-YBS). The goal was to combine the advantages of HPTLC with a more selective bioassay detection for bisphenols. The performance of this pA-YBS bioluminescence bioassay was demonstrated by calculating the half-maximal effective concentration (EC(50)) of bisphenols compared to references. The EC(50) ranged from 267 pg/band for bisphenol Z and 322 pg/band for bisphenol A (BPA) to > 1 ng/band for other bisphenols (BPC, BPE, BPF, and BPS) and references (17β-estradiol and 17α-ethinylestradiol). The EC(50) value of BPA was three times more sensitive in signal detection than that of 17β-estradiol. The visual or videodensitometric limit of detection of BPA was about 200 pg/zone. The higher signal intensity and sensitivity for BPA confirmed the tailored bioassay selectivity compared to the existing estrogen screen bioassay. It worked on different types of HPTLC silica gel plates. This HPTLC–UV/Vis/FLD–pA-YBS bioluminescence bioassay method was used to analyze complex mixtures such as six tin can migrates, five thermal papers, and eleven botanicals. The detected estrogenic compound zones in the tin can migrates were successfully verified via the duplex planar yeast antagonist estrogen screen (pYAES) bioassay. The two bisphenols A and S were identified in one out of five thermal papers and confirmed with high-resolution mass spectrometry. No bisphenols were detected in the botanicals investigated via the pA-YBS bioluminescence bioassay. However, the botanicals proved to contain phytoestrogens as detected via the pYAES bioassay, which confirmed the tailored bioassay selectivity. This HPTLC–UV/Vis/FLD–pA-YBS bioluminescence bioassay is suited for cost-efficient analysis of BPA in complex samples, with no need for sterile conditions due to the fast workflow. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04820-6. Springer Berlin Heidelberg 2023-07-17 2023 /pmc/articles/PMC10404207/ /pubmed/37458782 http://dx.doi.org/10.1007/s00216-023-04820-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Paper Jaber, Max Jähne, Martin Oberle, Michaela Morlock, Gertrud E. Screening bisphenols in complex samples via a planar Arxula adeninivorans bioluminescence bioassay |
title | Screening bisphenols in complex samples via a planar Arxula adeninivorans bioluminescence bioassay |
title_full | Screening bisphenols in complex samples via a planar Arxula adeninivorans bioluminescence bioassay |
title_fullStr | Screening bisphenols in complex samples via a planar Arxula adeninivorans bioluminescence bioassay |
title_full_unstemmed | Screening bisphenols in complex samples via a planar Arxula adeninivorans bioluminescence bioassay |
title_short | Screening bisphenols in complex samples via a planar Arxula adeninivorans bioluminescence bioassay |
title_sort | screening bisphenols in complex samples via a planar arxula adeninivorans bioluminescence bioassay |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404207/ https://www.ncbi.nlm.nih.gov/pubmed/37458782 http://dx.doi.org/10.1007/s00216-023-04820-6 |
work_keys_str_mv | AT jabermax screeningbisphenolsincomplexsamplesviaaplanararxulaadeninivoransbioluminescencebioassay AT jahnemartin screeningbisphenolsincomplexsamplesviaaplanararxulaadeninivoransbioluminescencebioassay AT oberlemichaela screeningbisphenolsincomplexsamplesviaaplanararxulaadeninivoransbioluminescencebioassay AT morlockgertrude screeningbisphenolsincomplexsamplesviaaplanararxulaadeninivoransbioluminescencebioassay |