Cargando…

Patient Pain and Satisfaction With 10, 30, and 70 mL Transcervical Foley Balloons for Cervical Ripening During Induction of Labor

Objective To assess patient pain and satisfaction and time to delivery following transcervical Foley catheter balloon inflation to 10, 30, or 70 mL with simultaneous administration of oxytocin. Methods We performed a randomized prospective study with 30 or 70 mL transcervical Foley balloon catheters...

Descripción completa

Detalles Bibliográficos
Autores principales: Dombrovsky, Inessa, Roloff, Kristina, Okekpe, C. Camille, Stowe, Robert, Valenzuela, Guillermo J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404459/
https://www.ncbi.nlm.nih.gov/pubmed/37551228
http://dx.doi.org/10.7759/cureus.41535
_version_ 1785085303970594816
author Dombrovsky, Inessa
Roloff, Kristina
Okekpe, C. Camille
Stowe, Robert
Valenzuela, Guillermo J
author_facet Dombrovsky, Inessa
Roloff, Kristina
Okekpe, C. Camille
Stowe, Robert
Valenzuela, Guillermo J
author_sort Dombrovsky, Inessa
collection PubMed
description Objective To assess patient pain and satisfaction and time to delivery following transcervical Foley catheter balloon inflation to 10, 30, or 70 mL with simultaneous administration of oxytocin. Methods We performed a randomized prospective study with 30 or 70 mL transcervical Foley balloon catheters in combination with oxytocin during labor induction at term. A 10 mL group was included as a sham control group. Time to delivery was measured, and a patient questionnaire was administered at the time the catheter was expelled to determine patient pain and satisfaction. Results In 120 enrolled patients, there was a non-significant trend toward reduced time to delivery in the large Foley balloon group (10 mL: 30:45 ± 38:53, 30 mL: 26:41 ± 20:53, and 70 mL 22:40 ± 15:35, hh:mm, P = 0.412). The pain score at the time the balloon was expelled was significantly higher in the 70 ml group compared to the 10 ml and 30 ml groups (P = 0.004 and P = 0.034, respectively). We found no other differences in patient satisfaction or pain scores at the time of placement of the Foley catheter for the three groups. Conclusion Small gains in time to delivery should be balanced against patient experiences, and expectations of pain during the ripening process should be addressed at the time of Foley insertion.
format Online
Article
Text
id pubmed-10404459
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-104044592023-08-07 Patient Pain and Satisfaction With 10, 30, and 70 mL Transcervical Foley Balloons for Cervical Ripening During Induction of Labor Dombrovsky, Inessa Roloff, Kristina Okekpe, C. Camille Stowe, Robert Valenzuela, Guillermo J Cureus Obstetrics/Gynecology Objective To assess patient pain and satisfaction and time to delivery following transcervical Foley catheter balloon inflation to 10, 30, or 70 mL with simultaneous administration of oxytocin. Methods We performed a randomized prospective study with 30 or 70 mL transcervical Foley balloon catheters in combination with oxytocin during labor induction at term. A 10 mL group was included as a sham control group. Time to delivery was measured, and a patient questionnaire was administered at the time the catheter was expelled to determine patient pain and satisfaction. Results In 120 enrolled patients, there was a non-significant trend toward reduced time to delivery in the large Foley balloon group (10 mL: 30:45 ± 38:53, 30 mL: 26:41 ± 20:53, and 70 mL 22:40 ± 15:35, hh:mm, P = 0.412). The pain score at the time the balloon was expelled was significantly higher in the 70 ml group compared to the 10 ml and 30 ml groups (P = 0.004 and P = 0.034, respectively). We found no other differences in patient satisfaction or pain scores at the time of placement of the Foley catheter for the three groups. Conclusion Small gains in time to delivery should be balanced against patient experiences, and expectations of pain during the ripening process should be addressed at the time of Foley insertion. Cureus 2023-07-07 /pmc/articles/PMC10404459/ /pubmed/37551228 http://dx.doi.org/10.7759/cureus.41535 Text en Copyright © 2023, Dombrovsky et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Obstetrics/Gynecology
Dombrovsky, Inessa
Roloff, Kristina
Okekpe, C. Camille
Stowe, Robert
Valenzuela, Guillermo J
Patient Pain and Satisfaction With 10, 30, and 70 mL Transcervical Foley Balloons for Cervical Ripening During Induction of Labor
title Patient Pain and Satisfaction With 10, 30, and 70 mL Transcervical Foley Balloons for Cervical Ripening During Induction of Labor
title_full Patient Pain and Satisfaction With 10, 30, and 70 mL Transcervical Foley Balloons for Cervical Ripening During Induction of Labor
title_fullStr Patient Pain and Satisfaction With 10, 30, and 70 mL Transcervical Foley Balloons for Cervical Ripening During Induction of Labor
title_full_unstemmed Patient Pain and Satisfaction With 10, 30, and 70 mL Transcervical Foley Balloons for Cervical Ripening During Induction of Labor
title_short Patient Pain and Satisfaction With 10, 30, and 70 mL Transcervical Foley Balloons for Cervical Ripening During Induction of Labor
title_sort patient pain and satisfaction with 10, 30, and 70 ml transcervical foley balloons for cervical ripening during induction of labor
topic Obstetrics/Gynecology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404459/
https://www.ncbi.nlm.nih.gov/pubmed/37551228
http://dx.doi.org/10.7759/cureus.41535
work_keys_str_mv AT dombrovskyinessa patientpainandsatisfactionwith1030and70mltranscervicalfoleyballoonsforcervicalripeningduringinductionoflabor
AT roloffkristina patientpainandsatisfactionwith1030and70mltranscervicalfoleyballoonsforcervicalripeningduringinductionoflabor
AT okekpeccamille patientpainandsatisfactionwith1030and70mltranscervicalfoleyballoonsforcervicalripeningduringinductionoflabor
AT stowerobert patientpainandsatisfactionwith1030and70mltranscervicalfoleyballoonsforcervicalripeningduringinductionoflabor
AT valenzuelaguillermoj patientpainandsatisfactionwith1030and70mltranscervicalfoleyballoonsforcervicalripeningduringinductionoflabor