Cargando…
Comparative analyses of DNA extraction methods for whole blood quantification of HCMV DNAemia in patients with hematological diseases: false negative cases in manual method
Human cytomegalovirus (HCMV) DNA quantitation in whole blood (WB) by real-time or quantitative polymerase chain reaction (qPCR) is a highly sensitive and reproducible diagnostic procedure for monitoring HCMV DNAemia (DNAemia is the detection of DNA in samples of plasma, whole blood, isolated periphe...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404732/ https://www.ncbi.nlm.nih.gov/pubmed/37554809 http://dx.doi.org/10.1016/j.heliyon.2023.e18740 |
_version_ | 1785085363196264448 |
---|---|
author | Bianchino, Gabriella Grieco, Vitina Pietrantuono, Giuseppe Russi, Sabino Del Vecchio, Luigi Falco, Geppino Notarangelo, Tiziana |
author_facet | Bianchino, Gabriella Grieco, Vitina Pietrantuono, Giuseppe Russi, Sabino Del Vecchio, Luigi Falco, Geppino Notarangelo, Tiziana |
author_sort | Bianchino, Gabriella |
collection | PubMed |
description | Human cytomegalovirus (HCMV) DNA quantitation in whole blood (WB) by real-time or quantitative polymerase chain reaction (qPCR) is a highly sensitive and reproducible diagnostic procedure for monitoring HCMV DNAemia (DNAemia is the detection of DNA in samples of plasma, whole blood, isolated peripheral blood leukocytes or in buffy-coat specimens) in patients. We provided a comparative analysis of HCMV DNA extraction performance by two different techniques, one performed by an automated extractor and the other by a manual method. We observed that the automated extraction method allowed HCMV DNA detection in the presence of weak viremia while no differences are observed when the viral load is greater. Therefore, automated DNA extraction is a suitable and recommended protocol not only for early detection of HCMV infection but also for more accurate monitoring of HCMV DNAemia during post-therapy follow-up. |
format | Online Article Text |
id | pubmed-10404732 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104047322023-08-08 Comparative analyses of DNA extraction methods for whole blood quantification of HCMV DNAemia in patients with hematological diseases: false negative cases in manual method Bianchino, Gabriella Grieco, Vitina Pietrantuono, Giuseppe Russi, Sabino Del Vecchio, Luigi Falco, Geppino Notarangelo, Tiziana Heliyon Research Article Human cytomegalovirus (HCMV) DNA quantitation in whole blood (WB) by real-time or quantitative polymerase chain reaction (qPCR) is a highly sensitive and reproducible diagnostic procedure for monitoring HCMV DNAemia (DNAemia is the detection of DNA in samples of plasma, whole blood, isolated peripheral blood leukocytes or in buffy-coat specimens) in patients. We provided a comparative analysis of HCMV DNA extraction performance by two different techniques, one performed by an automated extractor and the other by a manual method. We observed that the automated extraction method allowed HCMV DNA detection in the presence of weak viremia while no differences are observed when the viral load is greater. Therefore, automated DNA extraction is a suitable and recommended protocol not only for early detection of HCMV infection but also for more accurate monitoring of HCMV DNAemia during post-therapy follow-up. Elsevier 2023-07-27 /pmc/articles/PMC10404732/ /pubmed/37554809 http://dx.doi.org/10.1016/j.heliyon.2023.e18740 Text en © 2023 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Bianchino, Gabriella Grieco, Vitina Pietrantuono, Giuseppe Russi, Sabino Del Vecchio, Luigi Falco, Geppino Notarangelo, Tiziana Comparative analyses of DNA extraction methods for whole blood quantification of HCMV DNAemia in patients with hematological diseases: false negative cases in manual method |
title | Comparative analyses of DNA extraction methods for whole blood quantification of HCMV DNAemia in patients with hematological diseases: false negative cases in manual method |
title_full | Comparative analyses of DNA extraction methods for whole blood quantification of HCMV DNAemia in patients with hematological diseases: false negative cases in manual method |
title_fullStr | Comparative analyses of DNA extraction methods for whole blood quantification of HCMV DNAemia in patients with hematological diseases: false negative cases in manual method |
title_full_unstemmed | Comparative analyses of DNA extraction methods for whole blood quantification of HCMV DNAemia in patients with hematological diseases: false negative cases in manual method |
title_short | Comparative analyses of DNA extraction methods for whole blood quantification of HCMV DNAemia in patients with hematological diseases: false negative cases in manual method |
title_sort | comparative analyses of dna extraction methods for whole blood quantification of hcmv dnaemia in patients with hematological diseases: false negative cases in manual method |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404732/ https://www.ncbi.nlm.nih.gov/pubmed/37554809 http://dx.doi.org/10.1016/j.heliyon.2023.e18740 |
work_keys_str_mv | AT bianchinogabriella comparativeanalysesofdnaextractionmethodsforwholebloodquantificationofhcmvdnaemiainpatientswithhematologicaldiseasesfalsenegativecasesinmanualmethod AT griecovitina comparativeanalysesofdnaextractionmethodsforwholebloodquantificationofhcmvdnaemiainpatientswithhematologicaldiseasesfalsenegativecasesinmanualmethod AT pietrantuonogiuseppe comparativeanalysesofdnaextractionmethodsforwholebloodquantificationofhcmvdnaemiainpatientswithhematologicaldiseasesfalsenegativecasesinmanualmethod AT russisabino comparativeanalysesofdnaextractionmethodsforwholebloodquantificationofhcmvdnaemiainpatientswithhematologicaldiseasesfalsenegativecasesinmanualmethod AT delvecchioluigi comparativeanalysesofdnaextractionmethodsforwholebloodquantificationofhcmvdnaemiainpatientswithhematologicaldiseasesfalsenegativecasesinmanualmethod AT falcogeppino comparativeanalysesofdnaextractionmethodsforwholebloodquantificationofhcmvdnaemiainpatientswithhematologicaldiseasesfalsenegativecasesinmanualmethod AT notarangelotiziana comparativeanalysesofdnaextractionmethodsforwholebloodquantificationofhcmvdnaemiainpatientswithhematologicaldiseasesfalsenegativecasesinmanualmethod |