OBJECTIVE: The purpose of this study was to determine if uterine electrophysiological signals gathered from 151 non-invasive biomagnetic sensors spread over the abdomen were associated with successful induction of labor (IOL). STUDY DESIGN: Uterine magnetomyogram (MMG) signals were collected using t...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404855/ https://www.ncbi.nlm.nih.gov/pubmed/37554388 http://dx.doi.org/10.1016/j.crphys.2023.100103 |
_version_ | 1785085394669273088 |
---|---|
author | Mehl, Sarah T. Simmons, Pamela M. Whittington, Julie R. Escalona-Vargas, Diana Siegel, Eric R. Lowery, Curtis L. Crimmins-Pierce, Lauren D. Eswaran, Hari |
author_facet | Mehl, Sarah T. Simmons, Pamela M. Whittington, Julie R. Escalona-Vargas, Diana Siegel, Eric R. Lowery, Curtis L. Crimmins-Pierce, Lauren D. Eswaran, Hari |
author_sort | Mehl, Sarah T. |
collection | PubMed |
description | OBJECTIVE: The purpose of this study was to determine if uterine electrophysiological signals gathered from 151 non-invasive biomagnetic sensors spread over the abdomen were associated with successful induction of labor (IOL). STUDY DESIGN: Uterine magnetomyogram (MMG) signals were collected using the SARA (SQUID Array for Reproductive Assessment) device from 33 subjects between 37 and 42 weeks gestational age. The signals were post-processed, uterine contractile related MMG bursts were detected, and parameters in the time and frequency domain were extracted. The modified Bishop score calculated at admission was used to determine the method of IOL. Wilcoxon's rank-sum test was used to compare IOL successes and failures for differences in gestational age (GA), parity, modified Bishop's score, maximum oxytocin, and electrophysiological parameters extracted from MMG. RESULTS: The average parity was three times (3x) higher (1.53 versus 0.50; p = 0.039), and the average modified Bishop score was 2x higher (3.32 versus 1.63; p = 0.032) amongst IOL successes than failures, while the average GA and maximum oxytocin showed a small difference. For the MMG parameters, successful IOLs had, on average, 3.5x greater mean power during bursts (0.246 versus 0.070; p = 0.034) and approximately 1.2x greater mean number of bursts (2.05 versus 1.68; p = 0.036) compared to the failed IOLs, but non-significant differences were observed in mean peak frequency, mean burst duration, and mean duration between bursts. CONCLUSION: The study showed that inductions of labor that took less than 24 h to deliver have a higher mean power in the baseline electrophysiological activity of the uterus when recorded prior to planned induction. The results are indicative that baseline electrophysiological activity measured prior to induction is associated with successful induction. |
format | Online Article Text |
id | pubmed-10404855 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104048552023-08-08 Assessing uterine electrophysiology prior to elective term induction of labor Mehl, Sarah T. Simmons, Pamela M. Whittington, Julie R. Escalona-Vargas, Diana Siegel, Eric R. Lowery, Curtis L. Crimmins-Pierce, Lauren D. Eswaran, Hari Curr Res Physiol Articles from the special issue: Physiology, Female Reproduction and Bioengineering , edited by Susan Wray,Sarah England,Tina Chowdhury and Kristin Miller OBJECTIVE: The purpose of this study was to determine if uterine electrophysiological signals gathered from 151 non-invasive biomagnetic sensors spread over the abdomen were associated with successful induction of labor (IOL). STUDY DESIGN: Uterine magnetomyogram (MMG) signals were collected using the SARA (SQUID Array for Reproductive Assessment) device from 33 subjects between 37 and 42 weeks gestational age. The signals were post-processed, uterine contractile related MMG bursts were detected, and parameters in the time and frequency domain were extracted. The modified Bishop score calculated at admission was used to determine the method of IOL. Wilcoxon's rank-sum test was used to compare IOL successes and failures for differences in gestational age (GA), parity, modified Bishop's score, maximum oxytocin, and electrophysiological parameters extracted from MMG. RESULTS: The average parity was three times (3x) higher (1.53 versus 0.50; p = 0.039), and the average modified Bishop score was 2x higher (3.32 versus 1.63; p = 0.032) amongst IOL successes than failures, while the average GA and maximum oxytocin showed a small difference. For the MMG parameters, successful IOLs had, on average, 3.5x greater mean power during bursts (0.246 versus 0.070; p = 0.034) and approximately 1.2x greater mean number of bursts (2.05 versus 1.68; p = 0.036) compared to the failed IOLs, but non-significant differences were observed in mean peak frequency, mean burst duration, and mean duration between bursts. CONCLUSION: The study showed that inductions of labor that took less than 24 h to deliver have a higher mean power in the baseline electrophysiological activity of the uterus when recorded prior to planned induction. The results are indicative that baseline electrophysiological activity measured prior to induction is associated with successful induction. Elsevier 2023-07-21 /pmc/articles/PMC10404855/ /pubmed/37554388 http://dx.doi.org/10.1016/j.crphys.2023.100103 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Articles from the special issue: Physiology, Female Reproduction and Bioengineering , edited by Susan Wray,Sarah England,Tina Chowdhury and Kristin Miller Mehl, Sarah T. Simmons, Pamela M. Whittington, Julie R. Escalona-Vargas, Diana Siegel, Eric R. Lowery, Curtis L. Crimmins-Pierce, Lauren D. Eswaran, Hari Assessing uterine electrophysiology prior to elective term induction of labor |
title | Assessing uterine electrophysiology prior to elective term induction of labor |
title_full | Assessing uterine electrophysiology prior to elective term induction of labor |
title_fullStr | Assessing uterine electrophysiology prior to elective term induction of labor |
title_full_unstemmed | Assessing uterine electrophysiology prior to elective term induction of labor |
title_short | Assessing uterine electrophysiology prior to elective term induction of labor |
title_sort | assessing uterine electrophysiology prior to elective term induction of labor |
topic | Articles from the special issue: Physiology, Female Reproduction and Bioengineering , edited by Susan Wray,Sarah England,Tina Chowdhury and Kristin Miller |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404855/ https://www.ncbi.nlm.nih.gov/pubmed/37554388 http://dx.doi.org/10.1016/j.crphys.2023.100103 |
work_keys_str_mv | AT mehlsaraht assessinguterineelectrophysiologypriortoelectiveterminductionoflabor AT simmonspamelam assessinguterineelectrophysiologypriortoelectiveterminductionoflabor AT whittingtonjulier assessinguterineelectrophysiologypriortoelectiveterminductionoflabor AT escalonavargasdiana assessinguterineelectrophysiologypriortoelectiveterminductionoflabor AT siegelericr assessinguterineelectrophysiologypriortoelectiveterminductionoflabor AT lowerycurtisl assessinguterineelectrophysiologypriortoelectiveterminductionoflabor AT crimminspiercelaurend assessinguterineelectrophysiologypriortoelectiveterminductionoflabor AT eswaranhari assessinguterineelectrophysiologypriortoelectiveterminductionoflabor |