Cargando…

Assessing uterine electrophysiology prior to elective term induction of labor

OBJECTIVE: The purpose of this study was to determine if uterine electrophysiological signals gathered from 151 non-invasive biomagnetic sensors spread over the abdomen were associated with successful induction of labor (IOL). STUDY DESIGN: Uterine magnetomyogram (MMG) signals were collected using t...

Descripción completa

Detalles Bibliográficos
Autores principales: Mehl, Sarah T., Simmons, Pamela M., Whittington, Julie R., Escalona-Vargas, Diana, Siegel, Eric R., Lowery, Curtis L., Crimmins-Pierce, Lauren D., Eswaran, Hari
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404855/
https://www.ncbi.nlm.nih.gov/pubmed/37554388
http://dx.doi.org/10.1016/j.crphys.2023.100103
_version_ 1785085394669273088
author Mehl, Sarah T.
Simmons, Pamela M.
Whittington, Julie R.
Escalona-Vargas, Diana
Siegel, Eric R.
Lowery, Curtis L.
Crimmins-Pierce, Lauren D.
Eswaran, Hari
author_facet Mehl, Sarah T.
Simmons, Pamela M.
Whittington, Julie R.
Escalona-Vargas, Diana
Siegel, Eric R.
Lowery, Curtis L.
Crimmins-Pierce, Lauren D.
Eswaran, Hari
author_sort Mehl, Sarah T.
collection PubMed
description OBJECTIVE: The purpose of this study was to determine if uterine electrophysiological signals gathered from 151 non-invasive biomagnetic sensors spread over the abdomen were associated with successful induction of labor (IOL). STUDY DESIGN: Uterine magnetomyogram (MMG) signals were collected using the SARA (SQUID Array for Reproductive Assessment) device from 33 subjects between 37 and 42 weeks gestational age. The signals were post-processed, uterine contractile related MMG bursts were detected, and parameters in the time and frequency domain were extracted. The modified Bishop score calculated at admission was used to determine the method of IOL. Wilcoxon's rank-sum test was used to compare IOL successes and failures for differences in gestational age (GA), parity, modified Bishop's score, maximum oxytocin, and electrophysiological parameters extracted from MMG. RESULTS: The average parity was three times (3x) higher (1.53 versus 0.50; p = 0.039), and the average modified Bishop score was 2x higher (3.32 versus 1.63; p = 0.032) amongst IOL successes than failures, while the average GA and maximum oxytocin showed a small difference. For the MMG parameters, successful IOLs had, on average, 3.5x greater mean power during bursts (0.246 versus 0.070; p = 0.034) and approximately 1.2x greater mean number of bursts (2.05 versus 1.68; p = 0.036) compared to the failed IOLs, but non-significant differences were observed in mean peak frequency, mean burst duration, and mean duration between bursts. CONCLUSION: The study showed that inductions of labor that took less than 24 h to deliver have a higher mean power in the baseline electrophysiological activity of the uterus when recorded prior to planned induction. The results are indicative that baseline electrophysiological activity measured prior to induction is associated with successful induction.
format Online
Article
Text
id pubmed-10404855
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104048552023-08-08 Assessing uterine electrophysiology prior to elective term induction of labor Mehl, Sarah T. Simmons, Pamela M. Whittington, Julie R. Escalona-Vargas, Diana Siegel, Eric R. Lowery, Curtis L. Crimmins-Pierce, Lauren D. Eswaran, Hari Curr Res Physiol Articles from the special issue: Physiology, Female Reproduction and Bioengineering , edited by Susan Wray,Sarah England,Tina Chowdhury and Kristin Miller OBJECTIVE: The purpose of this study was to determine if uterine electrophysiological signals gathered from 151 non-invasive biomagnetic sensors spread over the abdomen were associated with successful induction of labor (IOL). STUDY DESIGN: Uterine magnetomyogram (MMG) signals were collected using the SARA (SQUID Array for Reproductive Assessment) device from 33 subjects between 37 and 42 weeks gestational age. The signals were post-processed, uterine contractile related MMG bursts were detected, and parameters in the time and frequency domain were extracted. The modified Bishop score calculated at admission was used to determine the method of IOL. Wilcoxon's rank-sum test was used to compare IOL successes and failures for differences in gestational age (GA), parity, modified Bishop's score, maximum oxytocin, and electrophysiological parameters extracted from MMG. RESULTS: The average parity was three times (3x) higher (1.53 versus 0.50; p = 0.039), and the average modified Bishop score was 2x higher (3.32 versus 1.63; p = 0.032) amongst IOL successes than failures, while the average GA and maximum oxytocin showed a small difference. For the MMG parameters, successful IOLs had, on average, 3.5x greater mean power during bursts (0.246 versus 0.070; p = 0.034) and approximately 1.2x greater mean number of bursts (2.05 versus 1.68; p = 0.036) compared to the failed IOLs, but non-significant differences were observed in mean peak frequency, mean burst duration, and mean duration between bursts. CONCLUSION: The study showed that inductions of labor that took less than 24 h to deliver have a higher mean power in the baseline electrophysiological activity of the uterus when recorded prior to planned induction. The results are indicative that baseline electrophysiological activity measured prior to induction is associated with successful induction. Elsevier 2023-07-21 /pmc/articles/PMC10404855/ /pubmed/37554388 http://dx.doi.org/10.1016/j.crphys.2023.100103 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Articles from the special issue: Physiology, Female Reproduction and Bioengineering , edited by Susan Wray,Sarah England,Tina Chowdhury and Kristin Miller
Mehl, Sarah T.
Simmons, Pamela M.
Whittington, Julie R.
Escalona-Vargas, Diana
Siegel, Eric R.
Lowery, Curtis L.
Crimmins-Pierce, Lauren D.
Eswaran, Hari
Assessing uterine electrophysiology prior to elective term induction of labor
title Assessing uterine electrophysiology prior to elective term induction of labor
title_full Assessing uterine electrophysiology prior to elective term induction of labor
title_fullStr Assessing uterine electrophysiology prior to elective term induction of labor
title_full_unstemmed Assessing uterine electrophysiology prior to elective term induction of labor
title_short Assessing uterine electrophysiology prior to elective term induction of labor
title_sort assessing uterine electrophysiology prior to elective term induction of labor
topic Articles from the special issue: Physiology, Female Reproduction and Bioengineering , edited by Susan Wray,Sarah England,Tina Chowdhury and Kristin Miller
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10404855/
https://www.ncbi.nlm.nih.gov/pubmed/37554388
http://dx.doi.org/10.1016/j.crphys.2023.100103
work_keys_str_mv AT mehlsaraht assessinguterineelectrophysiologypriortoelectiveterminductionoflabor
AT simmonspamelam assessinguterineelectrophysiologypriortoelectiveterminductionoflabor
AT whittingtonjulier assessinguterineelectrophysiologypriortoelectiveterminductionoflabor
AT escalonavargasdiana assessinguterineelectrophysiologypriortoelectiveterminductionoflabor
AT siegelericr assessinguterineelectrophysiologypriortoelectiveterminductionoflabor
AT lowerycurtisl assessinguterineelectrophysiologypriortoelectiveterminductionoflabor
AT crimminspiercelaurend assessinguterineelectrophysiologypriortoelectiveterminductionoflabor
AT eswaranhari assessinguterineelectrophysiologypriortoelectiveterminductionoflabor