Cargando…

Mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for O(2) consumption and H(2)O(2) yield

Objective. The objective of this study was to investigate the impact of mean and instantaneous dose rates on the production of reactive oxygen species (ROS) during ultra-high dose rate (UHDR) radiotherapy. The study aimed to determine whether either dose rate type plays a role in driving the FLASH e...

Descripción completa

Detalles Bibliográficos
Autores principales: Sunnerberg, Jacob P, Zhang, Rongxiao, Gladstone, David J, Swartz, Harold M, Gui, Jiang, Pogue, Brian W
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOP Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405361/
https://www.ncbi.nlm.nih.gov/pubmed/37463588
http://dx.doi.org/10.1088/1361-6560/ace877
_version_ 1785085510512803840
author Sunnerberg, Jacob P
Zhang, Rongxiao
Gladstone, David J
Swartz, Harold M
Gui, Jiang
Pogue, Brian W
author_facet Sunnerberg, Jacob P
Zhang, Rongxiao
Gladstone, David J
Swartz, Harold M
Gui, Jiang
Pogue, Brian W
author_sort Sunnerberg, Jacob P
collection PubMed
description Objective. The objective of this study was to investigate the impact of mean and instantaneous dose rates on the production of reactive oxygen species (ROS) during ultra-high dose rate (UHDR) radiotherapy. The study aimed to determine whether either dose rate type plays a role in driving the FLASH effect, a phenomenon where UHDR radiotherapy reduces damage to normal tissues while maintaining tumor control. Approach. Assays of hydrogen peroxide (H(2)O(2)) production and oxygen consumption (ΔpO(2)) were conducted using UHDR electron irradiation. Aqueous solutions of 4% albumin were utilized as the experimental medium. The study compared the effects of varying mean dose rates and instantaneous dose rates on ROS yields. Instantaneous dose rate was varied by changing the source-to-surface distance (SSD), resulting in instantaneous dose rates ranging from 10(2) to 10(6) Gy s(−1). Mean dose rate was manipulated by altering the pulse frequency of the linear accelerator (linac) and by changing the SSD, ranging from 0.14 to 1500 Gy s(−1). Main results. The study found that both ΔH(2)O(2) and ΔpO(2) decreased as the mean dose rate increased. Multivariate analysis indicated that instantaneous dose rates also contributed to this effect. The variation in ΔpO(2) was dependent on the initial oxygen concentration in the solution. Based on the analysis of dose rate variation, the study estimated that 7.51 moles of H(2)O(2) were produced for every mole of O(2) consumed. Significance. The results highlight the significance of mean dose rate as a predictor of ROS production during UHDR radiotherapy. As the mean dose rate increased, there was a decrease in oxygen consumption and in H(2)O(2) production. These findings have implications for understanding the FLASH effect and its potential optimization. The study sheds light on the role of dose rate parameters and their impact on radiochemical outcomes, contributing to the advancement of UHDR radiotherapy techniques.
format Online
Article
Text
id pubmed-10405361
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher IOP Publishing
record_format MEDLINE/PubMed
spelling pubmed-104053612023-08-08 Mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for O(2) consumption and H(2)O(2) yield Sunnerberg, Jacob P Zhang, Rongxiao Gladstone, David J Swartz, Harold M Gui, Jiang Pogue, Brian W Phys Med Biol Paper Objective. The objective of this study was to investigate the impact of mean and instantaneous dose rates on the production of reactive oxygen species (ROS) during ultra-high dose rate (UHDR) radiotherapy. The study aimed to determine whether either dose rate type plays a role in driving the FLASH effect, a phenomenon where UHDR radiotherapy reduces damage to normal tissues while maintaining tumor control. Approach. Assays of hydrogen peroxide (H(2)O(2)) production and oxygen consumption (ΔpO(2)) were conducted using UHDR electron irradiation. Aqueous solutions of 4% albumin were utilized as the experimental medium. The study compared the effects of varying mean dose rates and instantaneous dose rates on ROS yields. Instantaneous dose rate was varied by changing the source-to-surface distance (SSD), resulting in instantaneous dose rates ranging from 10(2) to 10(6) Gy s(−1). Mean dose rate was manipulated by altering the pulse frequency of the linear accelerator (linac) and by changing the SSD, ranging from 0.14 to 1500 Gy s(−1). Main results. The study found that both ΔH(2)O(2) and ΔpO(2) decreased as the mean dose rate increased. Multivariate analysis indicated that instantaneous dose rates also contributed to this effect. The variation in ΔpO(2) was dependent on the initial oxygen concentration in the solution. Based on the analysis of dose rate variation, the study estimated that 7.51 moles of H(2)O(2) were produced for every mole of O(2) consumed. Significance. The results highlight the significance of mean dose rate as a predictor of ROS production during UHDR radiotherapy. As the mean dose rate increased, there was a decrease in oxygen consumption and in H(2)O(2) production. These findings have implications for understanding the FLASH effect and its potential optimization. The study sheds light on the role of dose rate parameters and their impact on radiochemical outcomes, contributing to the advancement of UHDR radiotherapy techniques. IOP Publishing 2023-08-21 2023-08-07 /pmc/articles/PMC10405361/ /pubmed/37463588 http://dx.doi.org/10.1088/1361-6560/ace877 Text en © 2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd https://creativecommons.org/licenses/by/4.0/Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/) . Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
spellingShingle Paper
Sunnerberg, Jacob P
Zhang, Rongxiao
Gladstone, David J
Swartz, Harold M
Gui, Jiang
Pogue, Brian W
Mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for O(2) consumption and H(2)O(2) yield
title Mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for O(2) consumption and H(2)O(2) yield
title_full Mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for O(2) consumption and H(2)O(2) yield
title_fullStr Mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for O(2) consumption and H(2)O(2) yield
title_full_unstemmed Mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for O(2) consumption and H(2)O(2) yield
title_short Mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for O(2) consumption and H(2)O(2) yield
title_sort mean dose rate in ultra-high dose rate electron irradiation is a significant predictor for o(2) consumption and h(2)o(2) yield
topic Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405361/
https://www.ncbi.nlm.nih.gov/pubmed/37463588
http://dx.doi.org/10.1088/1361-6560/ace877
work_keys_str_mv AT sunnerbergjacobp meandoserateinultrahighdoserateelectronirradiationisasignificantpredictorforo2consumptionandh2o2yield
AT zhangrongxiao meandoserateinultrahighdoserateelectronirradiationisasignificantpredictorforo2consumptionandh2o2yield
AT gladstonedavidj meandoserateinultrahighdoserateelectronirradiationisasignificantpredictorforo2consumptionandh2o2yield
AT swartzharoldm meandoserateinultrahighdoserateelectronirradiationisasignificantpredictorforo2consumptionandh2o2yield
AT guijiang meandoserateinultrahighdoserateelectronirradiationisasignificantpredictorforo2consumptionandh2o2yield
AT poguebrianw meandoserateinultrahighdoserateelectronirradiationisasignificantpredictorforo2consumptionandh2o2yield