Cargando…

Assessing the Sensitivity of OCT-A Retinal Vasculature Metrics

PURPOSE: The purpose of this study was to examine the sensitivity of quantitative metrics of the retinal vasculature derived from optical coherence tomography angiography (OCT-A) images. METHODS: Full retinal vascular slab OCT-A images were obtained from 94 healthy participants. Capillary loss, at 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Szpernal, Jacob, Gaffney, Mina, Linderman, Rachel E., Langlo, Christopher S., Hemsworth, Katherine, Walesa, Ashleigh, Higgins, Brian P., Rosen, Richard B., Chui, Toco Y. P., Carroll, Joseph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405864/
https://www.ncbi.nlm.nih.gov/pubmed/37531114
http://dx.doi.org/10.1167/tvst.12.8.2
_version_ 1785085627669151744
author Szpernal, Jacob
Gaffney, Mina
Linderman, Rachel E.
Langlo, Christopher S.
Hemsworth, Katherine
Walesa, Ashleigh
Higgins, Brian P.
Rosen, Richard B.
Chui, Toco Y. P.
Carroll, Joseph
author_facet Szpernal, Jacob
Gaffney, Mina
Linderman, Rachel E.
Langlo, Christopher S.
Hemsworth, Katherine
Walesa, Ashleigh
Higgins, Brian P.
Rosen, Richard B.
Chui, Toco Y. P.
Carroll, Joseph
author_sort Szpernal, Jacob
collection PubMed
description PURPOSE: The purpose of this study was to examine the sensitivity of quantitative metrics of the retinal vasculature derived from optical coherence tomography angiography (OCT-A) images. METHODS: Full retinal vascular slab OCT-A images were obtained from 94 healthy participants. Capillary loss, at 1% increments up to 50%, was simulated by randomly removing capillary segments (1000 iterations of randomized loss for each participant at each percent loss). Thirteen quantitative metrics were calculated for each image: foveal avascular zone (FAZ) area, vessel density, vessel complexity index (VCI), vessel perimeter index (VPI), fractal dimension (FD), and parafoveal intercapillary area (PICA) measurements with and without the FAZ (mean PICA, summed PICA, PICA regularity, and PICA standard deviation [PICA SD]). The sensitivity of each metric was calculated as the percent loss at which 80% of the iterations for a participant fell outside of two standard deviations from the sample's normative mean. RESULTS: The most used OCT-A metrics, FAZ area and vessel density, were not significantly different from normative values until 27.69% and 16.00% capillary loss, respectively. Across the remaining metrics, metric sensitivity ranged from 6.37% (PICA SD without FAZ) to 39.78% (Summed PICA without FAZ). CONCLUSIONS: The sensitivity of vasculature metrics for detecting random capillary loss varies substantially. Further efforts simulating different patterns of capillary loss are needed for comparison. Additionally, mapping the repeatability of metrics over time in a normal population is needed to further define metric sensitivity. TRANSLATIONAL RELEVANCE: Quantitative metrics vary in their ability to detect vascular abnormalities in OCT-A images. Metric choice in screening studies will need to balance expected capillary abnormalities and the quality of the OCT-A images being used.
format Online
Article
Text
id pubmed-10405864
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-104058642023-08-08 Assessing the Sensitivity of OCT-A Retinal Vasculature Metrics Szpernal, Jacob Gaffney, Mina Linderman, Rachel E. Langlo, Christopher S. Hemsworth, Katherine Walesa, Ashleigh Higgins, Brian P. Rosen, Richard B. Chui, Toco Y. P. Carroll, Joseph Transl Vis Sci Technol Retina PURPOSE: The purpose of this study was to examine the sensitivity of quantitative metrics of the retinal vasculature derived from optical coherence tomography angiography (OCT-A) images. METHODS: Full retinal vascular slab OCT-A images were obtained from 94 healthy participants. Capillary loss, at 1% increments up to 50%, was simulated by randomly removing capillary segments (1000 iterations of randomized loss for each participant at each percent loss). Thirteen quantitative metrics were calculated for each image: foveal avascular zone (FAZ) area, vessel density, vessel complexity index (VCI), vessel perimeter index (VPI), fractal dimension (FD), and parafoveal intercapillary area (PICA) measurements with and without the FAZ (mean PICA, summed PICA, PICA regularity, and PICA standard deviation [PICA SD]). The sensitivity of each metric was calculated as the percent loss at which 80% of the iterations for a participant fell outside of two standard deviations from the sample's normative mean. RESULTS: The most used OCT-A metrics, FAZ area and vessel density, were not significantly different from normative values until 27.69% and 16.00% capillary loss, respectively. Across the remaining metrics, metric sensitivity ranged from 6.37% (PICA SD without FAZ) to 39.78% (Summed PICA without FAZ). CONCLUSIONS: The sensitivity of vasculature metrics for detecting random capillary loss varies substantially. Further efforts simulating different patterns of capillary loss are needed for comparison. Additionally, mapping the repeatability of metrics over time in a normal population is needed to further define metric sensitivity. TRANSLATIONAL RELEVANCE: Quantitative metrics vary in their ability to detect vascular abnormalities in OCT-A images. Metric choice in screening studies will need to balance expected capillary abnormalities and the quality of the OCT-A images being used. The Association for Research in Vision and Ophthalmology 2023-08-02 /pmc/articles/PMC10405864/ /pubmed/37531114 http://dx.doi.org/10.1167/tvst.12.8.2 Text en Copyright 2023 The Authors https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Retina
Szpernal, Jacob
Gaffney, Mina
Linderman, Rachel E.
Langlo, Christopher S.
Hemsworth, Katherine
Walesa, Ashleigh
Higgins, Brian P.
Rosen, Richard B.
Chui, Toco Y. P.
Carroll, Joseph
Assessing the Sensitivity of OCT-A Retinal Vasculature Metrics
title Assessing the Sensitivity of OCT-A Retinal Vasculature Metrics
title_full Assessing the Sensitivity of OCT-A Retinal Vasculature Metrics
title_fullStr Assessing the Sensitivity of OCT-A Retinal Vasculature Metrics
title_full_unstemmed Assessing the Sensitivity of OCT-A Retinal Vasculature Metrics
title_short Assessing the Sensitivity of OCT-A Retinal Vasculature Metrics
title_sort assessing the sensitivity of oct-a retinal vasculature metrics
topic Retina
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405864/
https://www.ncbi.nlm.nih.gov/pubmed/37531114
http://dx.doi.org/10.1167/tvst.12.8.2
work_keys_str_mv AT szpernaljacob assessingthesensitivityofoctaretinalvasculaturemetrics
AT gaffneymina assessingthesensitivityofoctaretinalvasculaturemetrics
AT lindermanrachele assessingthesensitivityofoctaretinalvasculaturemetrics
AT langlochristophers assessingthesensitivityofoctaretinalvasculaturemetrics
AT hemsworthkatherine assessingthesensitivityofoctaretinalvasculaturemetrics
AT walesaashleigh assessingthesensitivityofoctaretinalvasculaturemetrics
AT higginsbrianp assessingthesensitivityofoctaretinalvasculaturemetrics
AT rosenrichardb assessingthesensitivityofoctaretinalvasculaturemetrics
AT chuitocoyp assessingthesensitivityofoctaretinalvasculaturemetrics
AT carrolljoseph assessingthesensitivityofoctaretinalvasculaturemetrics