A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
BACKGROUND: The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting. METHODS: The HELIOS registry is a prospective, multicenter, cohort study condu...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405989/ https://www.ncbi.nlm.nih.gov/pubmed/37306407 http://dx.doi.org/10.1097/CM9.0000000000002324 |
_version_ | 1785085649926225920 |
---|---|
author | Zheng, Bo Liu, Yi Zhang, Ruining Yang, Wangwei Su, Fangju Wang, Rutao Chen, Dapeng Shen, Guidong Qiu, Yumin Wang, Lianmin Chen, Chang Wu, Zhongwei Li, Fei Li, Jiayi Li, Chengxiang Gao, Chao Tao, Ling |
author_facet | Zheng, Bo Liu, Yi Zhang, Ruining Yang, Wangwei Su, Fangju Wang, Rutao Chen, Dapeng Shen, Guidong Qiu, Yumin Wang, Lianmin Chen, Chang Wu, Zhongwei Li, Fei Li, Jiayi Li, Chengxiang Gao, Chao Tao, Ling |
author_sort | Zheng, Bo |
collection | PubMed |
description | BACKGROUND: The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting. METHODS: The HELIOS registry is a prospective, multicenter, cohort study conducted at 38 centers across China between November 2018 and December 2019. A total of 3060 consecutive patients were enrolled after application of minimal inclusion and exclusion criteria. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, non-fatal target vessel myocardial infarction (MI), and clinically indicated target lesion revascularization (TLR) at 1-year follow-up. Kaplan–Meier methods were used to estimate the cumulative incidence of clinical events and construct survival curves. RESULTS: A total of 2998 (98.0%) patients completed the 1-year follow-up. The 1-year incidence of TLF was 3.10% (94/2998, 95% closed interval: 2.54–3.78%). The rates of cardiac death, non-fatal target vessel MI and clinically indicated TLR were 2.33% (70/2998), 0.20% (6/2998), and 0.70% (21/2998), respectively. The rate of stent thrombosis was 0.33% (10/2998). Age ≥60 years, diabetes mellitus, family history of coronary artery disease, acute myocardial infarction at admission, and device success were independent predictors of TLF at 1 year. CONCLUSION: The 1-year incidence rates of TLF and stent thrombosis were 3.10% and 0.33%, respectively, in patients treated with HELIOS stents. Our results provide clinical evidence for interventional cardiologists and policymakers to evaluate HELIOS stent. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT03916432 |
format | Online Article Text |
id | pubmed-10405989 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-104059892023-08-08 A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry Zheng, Bo Liu, Yi Zhang, Ruining Yang, Wangwei Su, Fangju Wang, Rutao Chen, Dapeng Shen, Guidong Qiu, Yumin Wang, Lianmin Chen, Chang Wu, Zhongwei Li, Fei Li, Jiayi Li, Chengxiang Gao, Chao Tao, Ling Chin Med J (Engl) Original Articles BACKGROUND: The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting. METHODS: The HELIOS registry is a prospective, multicenter, cohort study conducted at 38 centers across China between November 2018 and December 2019. A total of 3060 consecutive patients were enrolled after application of minimal inclusion and exclusion criteria. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, non-fatal target vessel myocardial infarction (MI), and clinically indicated target lesion revascularization (TLR) at 1-year follow-up. Kaplan–Meier methods were used to estimate the cumulative incidence of clinical events and construct survival curves. RESULTS: A total of 2998 (98.0%) patients completed the 1-year follow-up. The 1-year incidence of TLF was 3.10% (94/2998, 95% closed interval: 2.54–3.78%). The rates of cardiac death, non-fatal target vessel MI and clinically indicated TLR were 2.33% (70/2998), 0.20% (6/2998), and 0.70% (21/2998), respectively. The rate of stent thrombosis was 0.33% (10/2998). Age ≥60 years, diabetes mellitus, family history of coronary artery disease, acute myocardial infarction at admission, and device success were independent predictors of TLF at 1 year. CONCLUSION: The 1-year incidence rates of TLF and stent thrombosis were 3.10% and 0.33%, respectively, in patients treated with HELIOS stents. Our results provide clinical evidence for interventional cardiologists and policymakers to evaluate HELIOS stent. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT03916432 Lippincott Williams & Wilkins 2023-08-05 2023-06-09 /pmc/articles/PMC10405989/ /pubmed/37306407 http://dx.doi.org/10.1097/CM9.0000000000002324 Text en Copyright © 2023 The Chinese Medical Association, produced by Wolters Kluwer, Inc. under the CC-BY-NC-ND license. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Articles Zheng, Bo Liu, Yi Zhang, Ruining Yang, Wangwei Su, Fangju Wang, Rutao Chen, Dapeng Shen, Guidong Qiu, Yumin Wang, Lianmin Chen, Chang Wu, Zhongwei Li, Fei Li, Jiayi Li, Chengxiang Gao, Chao Tao, Ling A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry |
title | A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry |
title_full | A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry |
title_fullStr | A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry |
title_full_unstemmed | A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry |
title_short | A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry |
title_sort | novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the helios registry |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405989/ https://www.ncbi.nlm.nih.gov/pubmed/37306407 http://dx.doi.org/10.1097/CM9.0000000000002324 |
work_keys_str_mv | AT zhengbo anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT liuyi anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT zhangruining anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT yangwangwei anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT sufangju anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT wangrutao anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT chendapeng anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT shenguidong anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT qiuyumin anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT wanglianmin anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT chenchang anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT wuzhongwei anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT lifei anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT lijiayi anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT lichengxiang anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT gaochao anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT taoling anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT zhengbo novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT liuyi novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT zhangruining novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT yangwangwei novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT sufangju novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT wangrutao novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT chendapeng novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT shenguidong novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT qiuyumin novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT wanglianmin novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT chenchang novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT wuzhongwei novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT lifei novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT lijiayi novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT lichengxiang novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT gaochao novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry AT taoling novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry |