Cargando…

A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry

BACKGROUND: The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting. METHODS: The HELIOS registry is a prospective, multicenter, cohort study condu...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Bo, Liu, Yi, Zhang, Ruining, Yang, Wangwei, Su, Fangju, Wang, Rutao, Chen, Dapeng, Shen, Guidong, Qiu, Yumin, Wang, Lianmin, Chen, Chang, Wu, Zhongwei, Li, Fei, Li, Jiayi, Li, Chengxiang, Gao, Chao, Tao, Ling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405989/
https://www.ncbi.nlm.nih.gov/pubmed/37306407
http://dx.doi.org/10.1097/CM9.0000000000002324
_version_ 1785085649926225920
author Zheng, Bo
Liu, Yi
Zhang, Ruining
Yang, Wangwei
Su, Fangju
Wang, Rutao
Chen, Dapeng
Shen, Guidong
Qiu, Yumin
Wang, Lianmin
Chen, Chang
Wu, Zhongwei
Li, Fei
Li, Jiayi
Li, Chengxiang
Gao, Chao
Tao, Ling
author_facet Zheng, Bo
Liu, Yi
Zhang, Ruining
Yang, Wangwei
Su, Fangju
Wang, Rutao
Chen, Dapeng
Shen, Guidong
Qiu, Yumin
Wang, Lianmin
Chen, Chang
Wu, Zhongwei
Li, Fei
Li, Jiayi
Li, Chengxiang
Gao, Chao
Tao, Ling
author_sort Zheng, Bo
collection PubMed
description BACKGROUND: The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting. METHODS: The HELIOS registry is a prospective, multicenter, cohort study conducted at 38 centers across China between November 2018 and December 2019. A total of 3060 consecutive patients were enrolled after application of minimal inclusion and exclusion criteria. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, non-fatal target vessel myocardial infarction (MI), and clinically indicated target lesion revascularization (TLR) at 1-year follow-up. Kaplan–Meier methods were used to estimate the cumulative incidence of clinical events and construct survival curves. RESULTS: A total of 2998 (98.0%) patients completed the 1-year follow-up. The 1-year incidence of TLF was 3.10% (94/2998, 95% closed interval: 2.54–3.78%). The rates of cardiac death, non-fatal target vessel MI and clinically indicated TLR were 2.33% (70/2998), 0.20% (6/2998), and 0.70% (21/2998), respectively. The rate of stent thrombosis was 0.33% (10/2998). Age ≥60 years, diabetes mellitus, family history of coronary artery disease, acute myocardial infarction at admission, and device success were independent predictors of TLF at 1 year. CONCLUSION: The 1-year incidence rates of TLF and stent thrombosis were 3.10% and 0.33%, respectively, in patients treated with HELIOS stents. Our results provide clinical evidence for interventional cardiologists and policymakers to evaluate HELIOS stent. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT03916432
format Online
Article
Text
id pubmed-10405989
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-104059892023-08-08 A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry Zheng, Bo Liu, Yi Zhang, Ruining Yang, Wangwei Su, Fangju Wang, Rutao Chen, Dapeng Shen, Guidong Qiu, Yumin Wang, Lianmin Chen, Chang Wu, Zhongwei Li, Fei Li, Jiayi Li, Chengxiang Gao, Chao Tao, Ling Chin Med J (Engl) Original Articles BACKGROUND: The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting. METHODS: The HELIOS registry is a prospective, multicenter, cohort study conducted at 38 centers across China between November 2018 and December 2019. A total of 3060 consecutive patients were enrolled after application of minimal inclusion and exclusion criteria. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, non-fatal target vessel myocardial infarction (MI), and clinically indicated target lesion revascularization (TLR) at 1-year follow-up. Kaplan–Meier methods were used to estimate the cumulative incidence of clinical events and construct survival curves. RESULTS: A total of 2998 (98.0%) patients completed the 1-year follow-up. The 1-year incidence of TLF was 3.10% (94/2998, 95% closed interval: 2.54–3.78%). The rates of cardiac death, non-fatal target vessel MI and clinically indicated TLR were 2.33% (70/2998), 0.20% (6/2998), and 0.70% (21/2998), respectively. The rate of stent thrombosis was 0.33% (10/2998). Age ≥60 years, diabetes mellitus, family history of coronary artery disease, acute myocardial infarction at admission, and device success were independent predictors of TLF at 1 year. CONCLUSION: The 1-year incidence rates of TLF and stent thrombosis were 3.10% and 0.33%, respectively, in patients treated with HELIOS stents. Our results provide clinical evidence for interventional cardiologists and policymakers to evaluate HELIOS stent. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT03916432 Lippincott Williams & Wilkins 2023-08-05 2023-06-09 /pmc/articles/PMC10405989/ /pubmed/37306407 http://dx.doi.org/10.1097/CM9.0000000000002324 Text en Copyright © 2023 The Chinese Medical Association, produced by Wolters Kluwer, Inc. under the CC-BY-NC-ND license. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Articles
Zheng, Bo
Liu, Yi
Zhang, Ruining
Yang, Wangwei
Su, Fangju
Wang, Rutao
Chen, Dapeng
Shen, Guidong
Qiu, Yumin
Wang, Lianmin
Chen, Chang
Wu, Zhongwei
Li, Fei
Li, Jiayi
Li, Chengxiang
Gao, Chao
Tao, Ling
A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
title A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
title_full A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
title_fullStr A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
title_full_unstemmed A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
title_short A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry
title_sort novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the helios registry
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405989/
https://www.ncbi.nlm.nih.gov/pubmed/37306407
http://dx.doi.org/10.1097/CM9.0000000000002324
work_keys_str_mv AT zhengbo anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT liuyi anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT zhangruining anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT yangwangwei anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT sufangju anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT wangrutao anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT chendapeng anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT shenguidong anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT qiuyumin anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT wanglianmin anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT chenchang anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT wuzhongwei anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT lifei anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT lijiayi anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT lichengxiang anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT gaochao anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT taoling anovelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT zhengbo novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT liuyi novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT zhangruining novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT yangwangwei novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT sufangju novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT wangrutao novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT chendapeng novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT shenguidong novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT qiuyumin novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT wanglianmin novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT chenchang novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT wuzhongwei novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT lifei novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT lijiayi novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT lichengxiang novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT gaochao novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry
AT taoling novelbiodegradablepolymercoatedsirolimuselutingstent1yearresultsoftheheliosregistry