Comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents
BACKGROUND. Using antibacterial agents to remove the foul odor of the implant cavity and prevent peri-implantitis can affect the detorque values and lead to the loosening of the abutment screw. This study investigated the effects of tetracycline and chlorhexidine gel on detorque values. METHODS. Thi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10407870/ https://www.ncbi.nlm.nih.gov/pubmed/37560492 http://dx.doi.org/10.34172/joddd.2022.038 |
_version_ | 1785086059244158976 |
---|---|
author | Nourizadeh, Amin Shafiee, Elnaz Khorramdel, Azin Mousavi, Seyed Amin Rahbar, Mehran |
author_facet | Nourizadeh, Amin Shafiee, Elnaz Khorramdel, Azin Mousavi, Seyed Amin Rahbar, Mehran |
author_sort | Nourizadeh, Amin |
collection | PubMed |
description | BACKGROUND. Using antibacterial agents to remove the foul odor of the implant cavity and prevent peri-implantitis can affect the detorque values and lead to the loosening of the abutment screw. This study investigated the effects of tetracycline and chlorhexidine gel on detorque values. METHODS. This in vitro study was carried out on three groups of five implants. Group G1 was the control group, and no material was applied to the implant cavity. In group G2, the implant cavity was first filled with artificial saliva and then with chlorhexidine gel. In group G3, the implant cavity was first filled with artificial saliva and then with tetracycline. The abutments were tightened with 25 N/cm(2) and then loosened. Finally, the detorque values were calculated. RESULTS. The highest detorque values were recorded in group G1. Group G3 showed the lowest detorque values. ANOVA showed significant differences in mean detorque values (P<0.05) between the three groups. CONCLUSION. According to this study, applying antibacterial agents decreased the detorque values and increased the risk of screw loosening. The reduction of detorque values was more pronounced with the oil-based antibacterial agent (tetracycline). |
format | Online Article Text |
id | pubmed-10407870 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Tabriz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-104078702023-08-09 Comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents Nourizadeh, Amin Shafiee, Elnaz Khorramdel, Azin Mousavi, Seyed Amin Rahbar, Mehran J Dent Res Dent Clin Dent Prospects Original Article BACKGROUND. Using antibacterial agents to remove the foul odor of the implant cavity and prevent peri-implantitis can affect the detorque values and lead to the loosening of the abutment screw. This study investigated the effects of tetracycline and chlorhexidine gel on detorque values. METHODS. This in vitro study was carried out on three groups of five implants. Group G1 was the control group, and no material was applied to the implant cavity. In group G2, the implant cavity was first filled with artificial saliva and then with chlorhexidine gel. In group G3, the implant cavity was first filled with artificial saliva and then with tetracycline. The abutments were tightened with 25 N/cm(2) and then loosened. Finally, the detorque values were calculated. RESULTS. The highest detorque values were recorded in group G1. Group G3 showed the lowest detorque values. ANOVA showed significant differences in mean detorque values (P<0.05) between the three groups. CONCLUSION. According to this study, applying antibacterial agents decreased the detorque values and increased the risk of screw loosening. The reduction of detorque values was more pronounced with the oil-based antibacterial agent (tetracycline). Tabriz University of Medical Sciences 2022 2022-12-30 /pmc/articles/PMC10407870/ /pubmed/37560492 http://dx.doi.org/10.34172/joddd.2022.038 Text en ©2022 The Author(s). https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium provided the original work is properly cited. |
spellingShingle | Original Article Nourizadeh, Amin Shafiee, Elnaz Khorramdel, Azin Mousavi, Seyed Amin Rahbar, Mehran Comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents |
title | Comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents |
title_full | Comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents |
title_fullStr | Comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents |
title_full_unstemmed | Comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents |
title_short | Comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents |
title_sort | comparison of reverse torque values of abutment screws with the application of oil-based and water-based antibacterial agents |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10407870/ https://www.ncbi.nlm.nih.gov/pubmed/37560492 http://dx.doi.org/10.34172/joddd.2022.038 |
work_keys_str_mv | AT nourizadehamin comparisonofreversetorquevaluesofabutmentscrewswiththeapplicationofoilbasedandwaterbasedantibacterialagents AT shafieeelnaz comparisonofreversetorquevaluesofabutmentscrewswiththeapplicationofoilbasedandwaterbasedantibacterialagents AT khorramdelazin comparisonofreversetorquevaluesofabutmentscrewswiththeapplicationofoilbasedandwaterbasedantibacterialagents AT mousaviseyedamin comparisonofreversetorquevaluesofabutmentscrewswiththeapplicationofoilbasedandwaterbasedantibacterialagents AT rahbarmehran comparisonofreversetorquevaluesofabutmentscrewswiththeapplicationofoilbasedandwaterbasedantibacterialagents |