In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers
Segmented polyurethane (PU) block copolymers are widely used in implantable cardiovascular medical devices due to their good biocompatibility and excellent mechanical properties. More specifically, PU Biospan MS/0.4 was used in ventricular assist devices over the past decades. However, this product...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10408244/ https://www.ncbi.nlm.nih.gov/pubmed/37470381 http://dx.doi.org/10.1177/08853282231191410 |
_version_ | 1785086147185082368 |
---|---|
author | Nguyen, Lan Xu, Li-Chong Yeager, Eric Weiss, William J Siedlecki, Christopher A |
author_facet | Nguyen, Lan Xu, Li-Chong Yeager, Eric Weiss, William J Siedlecki, Christopher A |
author_sort | Nguyen, Lan |
collection | PubMed |
description | Segmented polyurethane (PU) block copolymers are widely used in implantable cardiovascular medical devices due to their good biocompatibility and excellent mechanical properties. More specifically, PU Biospan MS/0.4 was used in ventricular assist devices over the past decades. However, this product is being discontinued and it has become necessary to find an alternative PU biomaterial for application in cardiovascular devices. One important criterion for assessing cardiac biomaterials is blood compatibility. In this study, we characterized the surface properties of four medical-grade PU biomaterials: Biospan MS/0.4, BioSpan S, BioSpan 2F, and CarboSil 20 80A, including surface chemistry, topography, microphase separation structure and wettability, and then measured the blood plasma coagulation responses using bovine and human blood plasma. Results showed that BioSpan 2F contains high amounts of fluorine and has the lowest surface free energy while the other materials have surfaces with silicone present. An in vitro coagulation assay shows that these materials demonstrated improved blood coagulation responses compared to the polystyrene control and there were no significant differences in coagulation time among all PU biomaterials. The chromogenic assay showed all PU materials led to low FXII contact activation, and there were no significant differences in FXII contact activation, consistent with plasma coagulation responses. |
format | Online Article Text |
id | pubmed-10408244 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-104082442023-08-09 In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers Nguyen, Lan Xu, Li-Chong Yeager, Eric Weiss, William J Siedlecki, Christopher A J Biomater Appl Soft Tissues and Materials Segmented polyurethane (PU) block copolymers are widely used in implantable cardiovascular medical devices due to their good biocompatibility and excellent mechanical properties. More specifically, PU Biospan MS/0.4 was used in ventricular assist devices over the past decades. However, this product is being discontinued and it has become necessary to find an alternative PU biomaterial for application in cardiovascular devices. One important criterion for assessing cardiac biomaterials is blood compatibility. In this study, we characterized the surface properties of four medical-grade PU biomaterials: Biospan MS/0.4, BioSpan S, BioSpan 2F, and CarboSil 20 80A, including surface chemistry, topography, microphase separation structure and wettability, and then measured the blood plasma coagulation responses using bovine and human blood plasma. Results showed that BioSpan 2F contains high amounts of fluorine and has the lowest surface free energy while the other materials have surfaces with silicone present. An in vitro coagulation assay shows that these materials demonstrated improved blood coagulation responses compared to the polystyrene control and there were no significant differences in coagulation time among all PU biomaterials. The chromogenic assay showed all PU materials led to low FXII contact activation, and there were no significant differences in FXII contact activation, consistent with plasma coagulation responses. SAGE Publications 2023-07-20 2023-08 /pmc/articles/PMC10408244/ /pubmed/37470381 http://dx.doi.org/10.1177/08853282231191410 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Soft Tissues and Materials Nguyen, Lan Xu, Li-Chong Yeager, Eric Weiss, William J Siedlecki, Christopher A In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers |
title | In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers |
title_full | In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers |
title_fullStr | In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers |
title_full_unstemmed | In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers |
title_short | In vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers |
title_sort | in vitro evaluation of blood plasma coagulation responses to four medical-grade polyurethane polymers |
topic | Soft Tissues and Materials |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10408244/ https://www.ncbi.nlm.nih.gov/pubmed/37470381 http://dx.doi.org/10.1177/08853282231191410 |
work_keys_str_mv | AT nguyenlan invitroevaluationofbloodplasmacoagulationresponsestofourmedicalgradepolyurethanepolymers AT xulichong invitroevaluationofbloodplasmacoagulationresponsestofourmedicalgradepolyurethanepolymers AT yeagereric invitroevaluationofbloodplasmacoagulationresponsestofourmedicalgradepolyurethanepolymers AT weisswilliamj invitroevaluationofbloodplasmacoagulationresponsestofourmedicalgradepolyurethanepolymers AT siedleckichristophera invitroevaluationofbloodplasmacoagulationresponsestofourmedicalgradepolyurethanepolymers |