Cargando…
A simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: Technical note
BACKGROUND: Endovascular coil embolization is increasingly being used for the treatment of intracranial aneurysms and other pathologies such as arteriovenous (AV) malformations and AV fistulas. Appropriate embolization technique requires a microcatheter with two radiopaque marks, one proximal and on...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Scientific Scholar
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10408614/ https://www.ncbi.nlm.nih.gov/pubmed/37560566 http://dx.doi.org/10.25259/SNI_381_2023 |
_version_ | 1785086201132220416 |
---|---|
author | Figueroa-Sanchez, Jose A. Martinez, Hector R. Avalos-Montes, Pablo J. Arreola-Aldape, Carlos A. Guerrero, Jose Alberto Moran Caro-Osorio, Enrique |
author_facet | Figueroa-Sanchez, Jose A. Martinez, Hector R. Avalos-Montes, Pablo J. Arreola-Aldape, Carlos A. Guerrero, Jose Alberto Moran Caro-Osorio, Enrique |
author_sort | Figueroa-Sanchez, Jose A. |
collection | PubMed |
description | BACKGROUND: Endovascular coil embolization is increasingly being used for the treatment of intracranial aneurysms and other pathologies such as arteriovenous (AV) malformations and AV fistulas. Appropriate embolization technique requires a microcatheter with two radiopaque marks, one proximal and one distal. We present an alternative coils deployment technique for intracranial aneurysms, using a microcatheter without a proximal radiopaque mark. METHODS: We describe the technique for embolization that was used in a 36-year-old female patient, in which we used a microcatheter without a proximal radiopaque mark for coil embolization of an intracranial aneurysm. RESULTS: We used a Headway Duo flow directed microcatheter for a coiling embolization of an intracranial aneurysm, solving the absence of the proximal radiopaque mark by cannulating the microcatheter with a Traxcess 0.014 microguidewire, and placing an external mark on the screen in the proximal portion of the microguidewire 30 mm radiopaque tip to indirectly mark the proximal mark of the microcatheter. CONCLUSION: There is scarce evidence supporting the use of microcatheters with no proximal radiopaque mark for coil embolization. This report attempts to disclose how an easy and simple technique can be used as a rescue method to solve the proximal radiopaque mark absence during endovascular coil release procedures. To the best of our knowledge, this technique has not been previously described; therefore, its use is not widespread among neurointerventionists. |
format | Online Article Text |
id | pubmed-10408614 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Scientific Scholar |
record_format | MEDLINE/PubMed |
spelling | pubmed-104086142023-08-09 A simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: Technical note Figueroa-Sanchez, Jose A. Martinez, Hector R. Avalos-Montes, Pablo J. Arreola-Aldape, Carlos A. Guerrero, Jose Alberto Moran Caro-Osorio, Enrique Surg Neurol Int Technical Notes BACKGROUND: Endovascular coil embolization is increasingly being used for the treatment of intracranial aneurysms and other pathologies such as arteriovenous (AV) malformations and AV fistulas. Appropriate embolization technique requires a microcatheter with two radiopaque marks, one proximal and one distal. We present an alternative coils deployment technique for intracranial aneurysms, using a microcatheter without a proximal radiopaque mark. METHODS: We describe the technique for embolization that was used in a 36-year-old female patient, in which we used a microcatheter without a proximal radiopaque mark for coil embolization of an intracranial aneurysm. RESULTS: We used a Headway Duo flow directed microcatheter for a coiling embolization of an intracranial aneurysm, solving the absence of the proximal radiopaque mark by cannulating the microcatheter with a Traxcess 0.014 microguidewire, and placing an external mark on the screen in the proximal portion of the microguidewire 30 mm radiopaque tip to indirectly mark the proximal mark of the microcatheter. CONCLUSION: There is scarce evidence supporting the use of microcatheters with no proximal radiopaque mark for coil embolization. This report attempts to disclose how an easy and simple technique can be used as a rescue method to solve the proximal radiopaque mark absence during endovascular coil release procedures. To the best of our knowledge, this technique has not been previously described; therefore, its use is not widespread among neurointerventionists. Scientific Scholar 2023-07-21 /pmc/articles/PMC10408614/ /pubmed/37560566 http://dx.doi.org/10.25259/SNI_381_2023 Text en Copyright: © 2023 Surgical Neurology International https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Technical Notes Figueroa-Sanchez, Jose A. Martinez, Hector R. Avalos-Montes, Pablo J. Arreola-Aldape, Carlos A. Guerrero, Jose Alberto Moran Caro-Osorio, Enrique A simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: Technical note |
title | A simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: Technical note |
title_full | A simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: Technical note |
title_fullStr | A simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: Technical note |
title_full_unstemmed | A simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: Technical note |
title_short | A simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: Technical note |
title_sort | simple but effective solution for proximal mark absence on some microcatheters in intracranial aneurysm embolization: technical note |
topic | Technical Notes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10408614/ https://www.ncbi.nlm.nih.gov/pubmed/37560566 http://dx.doi.org/10.25259/SNI_381_2023 |
work_keys_str_mv | AT figueroasanchezjosea asimplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT martinezhectorr asimplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT avalosmontespabloj asimplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT arreolaaldapecarlosa asimplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT guerrerojosealbertomoran asimplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT caroosorioenrique asimplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT figueroasanchezjosea simplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT martinezhectorr simplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT avalosmontespabloj simplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT arreolaaldapecarlosa simplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT guerrerojosealbertomoran simplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote AT caroosorioenrique simplebuteffectivesolutionforproximalmarkabsenceonsomemicrocathetersinintracranialaneurysmembolizationtechnicalnote |