Cargando…

Detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: A prospective observational study

BACKGROUND AND AIMS: Heparin-like effects (HLEs) can affect hemostasis during liver transplantation. The aim of this study was to assess the perioperative incidence and severity of HLE with rotational thromboelastometry (ROTEM) and activated partial thromboplastin time (aPTT). MATERIAL AND METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Yassen, Khaled A., Refaat, Emad K., Helal, Safaa M., Metwally, Ahmed A., Youssef, Sherin D., Görlinger, Klaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10410046/
https://www.ncbi.nlm.nih.gov/pubmed/37564856
http://dx.doi.org/10.4103/joacp.joacp_521_21
_version_ 1785086373366071296
author Yassen, Khaled A.
Refaat, Emad K.
Helal, Safaa M.
Metwally, Ahmed A.
Youssef, Sherin D.
Görlinger, Klaus
author_facet Yassen, Khaled A.
Refaat, Emad K.
Helal, Safaa M.
Metwally, Ahmed A.
Youssef, Sherin D.
Görlinger, Klaus
author_sort Yassen, Khaled A.
collection PubMed
description BACKGROUND AND AIMS: Heparin-like effects (HLEs) can affect hemostasis during liver transplantation. The aim of this study was to assess the perioperative incidence and severity of HLE with rotational thromboelastometry (ROTEM) and activated partial thromboplastin time (aPTT). MATERIAL AND METHODS: ROTEM and aPTT were measured intraoperatively and on postoperative days (POD) 1, 3, and 7. HLE was identified if ROTEM INTEM/HEPTEM CT-ratio was >1.25 and severe forms of HLE when ratio was ≥2. Based on aPTT, HLE was defined when aPTT ratio was >1.25 (patient aPTT/control aPTT). RESULTS: Thirty-eight recipients were included. Variable degrees of HLE were detected by aPTT-ratio and INTEM/HEPTEM CT ratio. No significant correlation existed between both ratios. Based on INTEM/HEPTEM CT ratio, HLE was detected in 7/38 during anhepatic phase, 19/38 post-reperfusion, 10/38 on POD1, 4/38 on POD3, and 0/38 on POD7. Four cases of severe HLE were identified by INTEM/HEPTEM CT ratio only in the anhepatic phase. Postoperative infusion of unfractionated heparin led to mild-moderate HLE on POD1 and 3 as evident by both tests. Red blood cell and plasma transfusion were higher with severe HLE (1350 ± 191 ml and 3558 ± 1407 ml). Composite adverse outcome of any complication or death within 3 months for patients without HLE, mild-moderate HLE, and severe HLE as detected by ROTEM was 27.8%, 42.9%, and 66.7%, respectively. CONCLUSION: INTEM/HEPTEM CT ratio was able to detect and quantify HLE as aPTT ratio. The ability of the INTEM/HEPTEM CT ratio to identify severe HLE earlier in the anhepatic phase needs to be studied in a larger population. HLE is self-limiting, but when identified in a severe form, it is associated with worse outcome.
format Online
Article
Text
id pubmed-10410046
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-104100462023-08-10 Detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: A prospective observational study Yassen, Khaled A. Refaat, Emad K. Helal, Safaa M. Metwally, Ahmed A. Youssef, Sherin D. Görlinger, Klaus J Anaesthesiol Clin Pharmacol Original Article BACKGROUND AND AIMS: Heparin-like effects (HLEs) can affect hemostasis during liver transplantation. The aim of this study was to assess the perioperative incidence and severity of HLE with rotational thromboelastometry (ROTEM) and activated partial thromboplastin time (aPTT). MATERIAL AND METHODS: ROTEM and aPTT were measured intraoperatively and on postoperative days (POD) 1, 3, and 7. HLE was identified if ROTEM INTEM/HEPTEM CT-ratio was >1.25 and severe forms of HLE when ratio was ≥2. Based on aPTT, HLE was defined when aPTT ratio was >1.25 (patient aPTT/control aPTT). RESULTS: Thirty-eight recipients were included. Variable degrees of HLE were detected by aPTT-ratio and INTEM/HEPTEM CT ratio. No significant correlation existed between both ratios. Based on INTEM/HEPTEM CT ratio, HLE was detected in 7/38 during anhepatic phase, 19/38 post-reperfusion, 10/38 on POD1, 4/38 on POD3, and 0/38 on POD7. Four cases of severe HLE were identified by INTEM/HEPTEM CT ratio only in the anhepatic phase. Postoperative infusion of unfractionated heparin led to mild-moderate HLE on POD1 and 3 as evident by both tests. Red blood cell and plasma transfusion were higher with severe HLE (1350 ± 191 ml and 3558 ± 1407 ml). Composite adverse outcome of any complication or death within 3 months for patients without HLE, mild-moderate HLE, and severe HLE as detected by ROTEM was 27.8%, 42.9%, and 66.7%, respectively. CONCLUSION: INTEM/HEPTEM CT ratio was able to detect and quantify HLE as aPTT ratio. The ability of the INTEM/HEPTEM CT ratio to identify severe HLE earlier in the anhepatic phase needs to be studied in a larger population. HLE is self-limiting, but when identified in a severe form, it is associated with worse outcome. Wolters Kluwer - Medknow 2023 2022-06-15 /pmc/articles/PMC10410046/ /pubmed/37564856 http://dx.doi.org/10.4103/joacp.joacp_521_21 Text en Copyright: © 2022 Journal of Anaesthesiology Clinical Pharmacology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Yassen, Khaled A.
Refaat, Emad K.
Helal, Safaa M.
Metwally, Ahmed A.
Youssef, Sherin D.
Görlinger, Klaus
Detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: A prospective observational study
title Detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: A prospective observational study
title_full Detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: A prospective observational study
title_fullStr Detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: A prospective observational study
title_full_unstemmed Detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: A prospective observational study
title_short Detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: A prospective observational study
title_sort detection and quantification of perioperative heparin-like effects by rotational thromboelastometry in living-donor liver transplant recipients: a prospective observational study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10410046/
https://www.ncbi.nlm.nih.gov/pubmed/37564856
http://dx.doi.org/10.4103/joacp.joacp_521_21
work_keys_str_mv AT yassenkhaleda detectionandquantificationofperioperativeheparinlikeeffectsbyrotationalthromboelastometryinlivingdonorlivertransplantrecipientsaprospectiveobservationalstudy
AT refaatemadk detectionandquantificationofperioperativeheparinlikeeffectsbyrotationalthromboelastometryinlivingdonorlivertransplantrecipientsaprospectiveobservationalstudy
AT helalsafaam detectionandquantificationofperioperativeheparinlikeeffectsbyrotationalthromboelastometryinlivingdonorlivertransplantrecipientsaprospectiveobservationalstudy
AT metwallyahmeda detectionandquantificationofperioperativeheparinlikeeffectsbyrotationalthromboelastometryinlivingdonorlivertransplantrecipientsaprospectiveobservationalstudy
AT youssefsherind detectionandquantificationofperioperativeheparinlikeeffectsbyrotationalthromboelastometryinlivingdonorlivertransplantrecipientsaprospectiveobservationalstudy
AT gorlingerklaus detectionandquantificationofperioperativeheparinlikeeffectsbyrotationalthromboelastometryinlivingdonorlivertransplantrecipientsaprospectiveobservationalstudy