Cargando…
A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study
OBJECTIVES: The aim of the present study was to predict the vault of implantable collamer lens (ICL) using a formula established based on the preoperative parameters. METHODS: This retrospective study included data on 226 eyes from 114 patients(the median age and range was 27.5 ± 5.7; 18–46 years) w...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10411000/ https://www.ncbi.nlm.nih.gov/pubmed/37553616 http://dx.doi.org/10.1186/s12886-023-03096-9 |
_version_ | 1785086577602461696 |
---|---|
author | Yang, Jing Li, Hui Wu, Minhui He, Runzhang Nong, Yating Zou, Zongyin Zhang, Chun Zhou, Sheng |
author_facet | Yang, Jing Li, Hui Wu, Minhui He, Runzhang Nong, Yating Zou, Zongyin Zhang, Chun Zhou, Sheng |
author_sort | Yang, Jing |
collection | PubMed |
description | OBJECTIVES: The aim of the present study was to predict the vault of implantable collamer lens (ICL) using a formula established based on the preoperative parameters. METHODS: This retrospective study included data on 226 eyes from 114 patients(the median age and range was 27.5 ± 5.7; 18–46 years) who underwent EVO-ICL surgery between May 2021 and April 2022. Preoperative parameters, such as anterior chamber depth (ACD) horizontal angle-to-angle diameter (ATA), Crystalline lens rise (CLR), and vault (1 week after surgery) were measured by anterior segment optical coherence tomography. The axial length of eyes (AL) and white-to-white (WTW) values were measured using an IOLmaster and calipers under a slit lamp separately. RESULT: The mean WTW, ACD, horizontal ATA diameter, CLR, AL, and vault 1 week after surgery were 11.42 ± 0.37 mm, 3.25 ± 0.25 mm, 11.72 ± 0.44 mm, 45.78 ± 175.42 μm, 27.61 ± 1.93 mm, and 586.51 ± 254.54 μm respectively. Multivariate regression analysis showed that the ICL-width, ACD (β = 0.293), ATA (β =-0.657), CLR (β =-0.157), and the anterior chamber angle in temporal side (T:ACA) (β=-0.277) were predictors of the vault size (adjusted-R(2) = 0.39, P < 0.001). CONCLUSION: The formula built based on these preoperative parameters could be used to predict the vault before surgery. The predictors indicated that the pre-operative parameters of eye such as ACD, ATA, CLR and T:ACA play an important role in choosing optimal ICL size. |
format | Online Article Text |
id | pubmed-10411000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-104110002023-08-10 A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study Yang, Jing Li, Hui Wu, Minhui He, Runzhang Nong, Yating Zou, Zongyin Zhang, Chun Zhou, Sheng BMC Ophthalmol Research OBJECTIVES: The aim of the present study was to predict the vault of implantable collamer lens (ICL) using a formula established based on the preoperative parameters. METHODS: This retrospective study included data on 226 eyes from 114 patients(the median age and range was 27.5 ± 5.7; 18–46 years) who underwent EVO-ICL surgery between May 2021 and April 2022. Preoperative parameters, such as anterior chamber depth (ACD) horizontal angle-to-angle diameter (ATA), Crystalline lens rise (CLR), and vault (1 week after surgery) were measured by anterior segment optical coherence tomography. The axial length of eyes (AL) and white-to-white (WTW) values were measured using an IOLmaster and calipers under a slit lamp separately. RESULT: The mean WTW, ACD, horizontal ATA diameter, CLR, AL, and vault 1 week after surgery were 11.42 ± 0.37 mm, 3.25 ± 0.25 mm, 11.72 ± 0.44 mm, 45.78 ± 175.42 μm, 27.61 ± 1.93 mm, and 586.51 ± 254.54 μm respectively. Multivariate regression analysis showed that the ICL-width, ACD (β = 0.293), ATA (β =-0.657), CLR (β =-0.157), and the anterior chamber angle in temporal side (T:ACA) (β=-0.277) were predictors of the vault size (adjusted-R(2) = 0.39, P < 0.001). CONCLUSION: The formula built based on these preoperative parameters could be used to predict the vault before surgery. The predictors indicated that the pre-operative parameters of eye such as ACD, ATA, CLR and T:ACA play an important role in choosing optimal ICL size. BioMed Central 2023-08-08 /pmc/articles/PMC10411000/ /pubmed/37553616 http://dx.doi.org/10.1186/s12886-023-03096-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yang, Jing Li, Hui Wu, Minhui He, Runzhang Nong, Yating Zou, Zongyin Zhang, Chun Zhou, Sheng A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study |
title | A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study |
title_full | A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study |
title_fullStr | A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study |
title_full_unstemmed | A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study |
title_short | A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study |
title_sort | vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10411000/ https://www.ncbi.nlm.nih.gov/pubmed/37553616 http://dx.doi.org/10.1186/s12886-023-03096-9 |
work_keys_str_mv | AT yangjing avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT lihui avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT wuminhui avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT herunzhang avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT nongyating avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT zouzongyin avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT zhangchun avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT zhousheng avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT yangjing vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT lihui vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT wuminhui vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT herunzhang vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT nongyating vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT zouzongyin vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT zhangchun vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy AT zhousheng vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy |