Cargando…

A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study

OBJECTIVES: The aim of the present study was to predict the vault of implantable collamer lens (ICL) using a formula established based on the preoperative parameters. METHODS: This retrospective study included data on 226 eyes from 114 patients(the median age and range was 27.5 ± 5.7; 18–46 years) w...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Jing, Li, Hui, Wu, Minhui, He, Runzhang, Nong, Yating, Zou, Zongyin, Zhang, Chun, Zhou, Sheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10411000/
https://www.ncbi.nlm.nih.gov/pubmed/37553616
http://dx.doi.org/10.1186/s12886-023-03096-9
_version_ 1785086577602461696
author Yang, Jing
Li, Hui
Wu, Minhui
He, Runzhang
Nong, Yating
Zou, Zongyin
Zhang, Chun
Zhou, Sheng
author_facet Yang, Jing
Li, Hui
Wu, Minhui
He, Runzhang
Nong, Yating
Zou, Zongyin
Zhang, Chun
Zhou, Sheng
author_sort Yang, Jing
collection PubMed
description OBJECTIVES: The aim of the present study was to predict the vault of implantable collamer lens (ICL) using a formula established based on the preoperative parameters. METHODS: This retrospective study included data on 226 eyes from 114 patients(the median age and range was 27.5 ± 5.7; 18–46 years) who underwent EVO-ICL surgery between May 2021 and April 2022. Preoperative parameters, such as anterior chamber depth (ACD) horizontal angle-to-angle diameter (ATA), Crystalline lens rise (CLR), and vault (1 week after surgery) were measured by anterior segment optical coherence tomography. The axial length of eyes (AL) and white-to-white (WTW) values were measured using an IOLmaster and calipers under a slit lamp separately. RESULT: The mean WTW, ACD, horizontal ATA diameter, CLR, AL, and vault 1 week after surgery were 11.42 ± 0.37 mm, 3.25 ± 0.25 mm, 11.72 ± 0.44 mm, 45.78 ± 175.42 μm, 27.61 ± 1.93 mm, and 586.51 ± 254.54 μm respectively. Multivariate regression analysis showed that the ICL-width, ACD (β = 0.293), ATA (β =-0.657), CLR (β =-0.157), and the anterior chamber angle in temporal side (T:ACA) (β=-0.277) were predictors of the vault size (adjusted-R(2) = 0.39, P < 0.001). CONCLUSION: The formula built based on these preoperative parameters could be used to predict the vault before surgery. The predictors indicated that the pre-operative parameters of eye such as ACD, ATA, CLR and T:ACA play an important role in choosing optimal ICL size.
format Online
Article
Text
id pubmed-10411000
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-104110002023-08-10 A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study Yang, Jing Li, Hui Wu, Minhui He, Runzhang Nong, Yating Zou, Zongyin Zhang, Chun Zhou, Sheng BMC Ophthalmol Research OBJECTIVES: The aim of the present study was to predict the vault of implantable collamer lens (ICL) using a formula established based on the preoperative parameters. METHODS: This retrospective study included data on 226 eyes from 114 patients(the median age and range was 27.5 ± 5.7; 18–46 years) who underwent EVO-ICL surgery between May 2021 and April 2022. Preoperative parameters, such as anterior chamber depth (ACD) horizontal angle-to-angle diameter (ATA), Crystalline lens rise (CLR), and vault (1 week after surgery) were measured by anterior segment optical coherence tomography. The axial length of eyes (AL) and white-to-white (WTW) values were measured using an IOLmaster and calipers under a slit lamp separately. RESULT: The mean WTW, ACD, horizontal ATA diameter, CLR, AL, and vault 1 week after surgery were 11.42 ± 0.37 mm, 3.25 ± 0.25 mm, 11.72 ± 0.44 mm, 45.78 ± 175.42 μm, 27.61 ± 1.93 mm, and 586.51 ± 254.54 μm respectively. Multivariate regression analysis showed that the ICL-width, ACD (β = 0.293), ATA (β =-0.657), CLR (β =-0.157), and the anterior chamber angle in temporal side (T:ACA) (β=-0.277) were predictors of the vault size (adjusted-R(2) = 0.39, P < 0.001). CONCLUSION: The formula built based on these preoperative parameters could be used to predict the vault before surgery. The predictors indicated that the pre-operative parameters of eye such as ACD, ATA, CLR and T:ACA play an important role in choosing optimal ICL size. BioMed Central 2023-08-08 /pmc/articles/PMC10411000/ /pubmed/37553616 http://dx.doi.org/10.1186/s12886-023-03096-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Yang, Jing
Li, Hui
Wu, Minhui
He, Runzhang
Nong, Yating
Zou, Zongyin
Zhang, Chun
Zhou, Sheng
A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study
title A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study
title_full A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study
title_fullStr A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study
title_full_unstemmed A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study
title_short A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study
title_sort vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10411000/
https://www.ncbi.nlm.nih.gov/pubmed/37553616
http://dx.doi.org/10.1186/s12886-023-03096-9
work_keys_str_mv AT yangjing avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT lihui avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT wuminhui avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT herunzhang avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT nongyating avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT zouzongyin avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT zhangchun avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT zhousheng avaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT yangjing vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT lihui vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT wuminhui vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT herunzhang vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT nongyating vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT zouzongyin vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT zhangchun vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy
AT zhousheng vaultpredictionformulaforimplantablecollamerlensbasedonpreoperativeparametersaretrospectiveclinicalstudy