Cargando…

Expiratory-gated Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) does not Further Augment Heart Rate Variability During Slow Breathing at 0.1 Hz

As cardiac vagal control is a hallmark of good health and self-regulatory capacity, researchers are seeking ways to increase vagally mediated heart rate variability (vmHRV) in an accessible and non-invasive way. Findings with transcutaneous auricular vagus nerve stimulation (taVNS) have been disappo...

Descripción completa

Detalles Bibliográficos
Autores principales: Szulczewski, Mikołaj Tytus, D’Agostini, Martina, Van Diest, Ilse
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10412484/
https://www.ncbi.nlm.nih.gov/pubmed/36920567
http://dx.doi.org/10.1007/s10484-023-09584-4
_version_ 1785086916748640256
author Szulczewski, Mikołaj Tytus
D’Agostini, Martina
Van Diest, Ilse
author_facet Szulczewski, Mikołaj Tytus
D’Agostini, Martina
Van Diest, Ilse
author_sort Szulczewski, Mikołaj Tytus
collection PubMed
description As cardiac vagal control is a hallmark of good health and self-regulatory capacity, researchers are seeking ways to increase vagally mediated heart rate variability (vmHRV) in an accessible and non-invasive way. Findings with transcutaneous auricular vagus nerve stimulation (taVNS) have been disappointing in this respect, as its effects on vmHRV are inconsistent at best. It has been speculated that combining taVNS with other established ways to increase vmHRV may produce synergistic effects. To test this idea, the present study combined taVNS with slow breathing in a cross-over design. A total of 22 participants took part in two sessions of breathing at 6 breaths/min: once combined with taVNS, and once combined with sham stimulation. Electrical stimulation (100 Hz, 400 µs) was applied during expiration, either to the tragus and cavum conchae (taVNS) or to the earlobe (sham). ECG was recorded during baseline, 20-minutes of stimulation, and the recovery period. Frequentist and Bayesian analyses showed no effect of taVNS (in comparison to sham stimulation) on the root mean square of successive differences between normal heartbeats, mean inter-beat interval, or spectral power of heart rate variability at a breathing frequency of 0.1 Hz. These findings suggest that expiratory-gated taVNS combined with the stimulation parameters examined here does not produce acute effects on vmHRV during slow breathing.
format Online
Article
Text
id pubmed-10412484
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-104124842023-08-11 Expiratory-gated Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) does not Further Augment Heart Rate Variability During Slow Breathing at 0.1 Hz Szulczewski, Mikołaj Tytus D’Agostini, Martina Van Diest, Ilse Appl Psychophysiol Biofeedback Article As cardiac vagal control is a hallmark of good health and self-regulatory capacity, researchers are seeking ways to increase vagally mediated heart rate variability (vmHRV) in an accessible and non-invasive way. Findings with transcutaneous auricular vagus nerve stimulation (taVNS) have been disappointing in this respect, as its effects on vmHRV are inconsistent at best. It has been speculated that combining taVNS with other established ways to increase vmHRV may produce synergistic effects. To test this idea, the present study combined taVNS with slow breathing in a cross-over design. A total of 22 participants took part in two sessions of breathing at 6 breaths/min: once combined with taVNS, and once combined with sham stimulation. Electrical stimulation (100 Hz, 400 µs) was applied during expiration, either to the tragus and cavum conchae (taVNS) or to the earlobe (sham). ECG was recorded during baseline, 20-minutes of stimulation, and the recovery period. Frequentist and Bayesian analyses showed no effect of taVNS (in comparison to sham stimulation) on the root mean square of successive differences between normal heartbeats, mean inter-beat interval, or spectral power of heart rate variability at a breathing frequency of 0.1 Hz. These findings suggest that expiratory-gated taVNS combined with the stimulation parameters examined here does not produce acute effects on vmHRV during slow breathing. Springer US 2023-03-15 2023 /pmc/articles/PMC10412484/ /pubmed/36920567 http://dx.doi.org/10.1007/s10484-023-09584-4 Text en © The Author(s) 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Szulczewski, Mikołaj Tytus
D’Agostini, Martina
Van Diest, Ilse
Expiratory-gated Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) does not Further Augment Heart Rate Variability During Slow Breathing at 0.1 Hz
title Expiratory-gated Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) does not Further Augment Heart Rate Variability During Slow Breathing at 0.1 Hz
title_full Expiratory-gated Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) does not Further Augment Heart Rate Variability During Slow Breathing at 0.1 Hz
title_fullStr Expiratory-gated Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) does not Further Augment Heart Rate Variability During Slow Breathing at 0.1 Hz
title_full_unstemmed Expiratory-gated Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) does not Further Augment Heart Rate Variability During Slow Breathing at 0.1 Hz
title_short Expiratory-gated Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) does not Further Augment Heart Rate Variability During Slow Breathing at 0.1 Hz
title_sort expiratory-gated transcutaneous auricular vagus nerve stimulation (tavns) does not further augment heart rate variability during slow breathing at 0.1 hz
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10412484/
https://www.ncbi.nlm.nih.gov/pubmed/36920567
http://dx.doi.org/10.1007/s10484-023-09584-4
work_keys_str_mv AT szulczewskimikołajtytus expiratorygatedtranscutaneousauricularvagusnervestimulationtavnsdoesnotfurtheraugmentheartratevariabilityduringslowbreathingat01hz
AT dagostinimartina expiratorygatedtranscutaneousauricularvagusnervestimulationtavnsdoesnotfurtheraugmentheartratevariabilityduringslowbreathingat01hz
AT vandiestilse expiratorygatedtranscutaneousauricularvagusnervestimulationtavnsdoesnotfurtheraugmentheartratevariabilityduringslowbreathingat01hz