Cargando…

Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions

BACKGROUND: Novel approaches using virtual computed tomography (CT) guidance, namely electromagnetic navigation transthoracic needle biopsy (EMN-TTNB), enable physicians to perform percutaneous lung biopsies. However, there are very few studies on the clinical experiences of EMN-TTNB, and in previou...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, SoJeong, Kim, NaYoung, Chung, SooJie, Kim, JungHyun, Hyun, InGyu, Choi, JeongHee, Lee, HeeSung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413044/
https://www.ncbi.nlm.nih.gov/pubmed/37577320
http://dx.doi.org/10.21037/tlcr-23-111
_version_ 1785087049319055360
author Kim, SoJeong
Kim, NaYoung
Chung, SooJie
Kim, JungHyun
Hyun, InGyu
Choi, JeongHee
Lee, HeeSung
author_facet Kim, SoJeong
Kim, NaYoung
Chung, SooJie
Kim, JungHyun
Hyun, InGyu
Choi, JeongHee
Lee, HeeSung
author_sort Kim, SoJeong
collection PubMed
description BACKGROUND: Novel approaches using virtual computed tomography (CT) guidance, namely electromagnetic navigation transthoracic needle biopsy (EMN-TTNB), enable physicians to perform percutaneous lung biopsies. However, there are very few studies on the clinical experiences of EMN-TTNB, and in previous studies, the procedure was usually performed under deep sedation. This study aimed to determine the diagnostic accuracy and safety of EMN-TTNB under moderate sedation. METHODS: We conducted a retrospective analysis of patients who underwent EMN-TTNB under moderate sedation between May 2021 and November 2022 at Hallym University Dongtan Sacred Heart Hospital in South Korea. Moderate sedation was achieved with midazolam injection in the bronchoscopy room using the Veran SPiNperc EM guidance system (Veran Medical, St Louis, MO, USA). Clinical data were collected by review of medical records, and diagnostic accuracy and safety were calculated. RESULTS: Thirty-two patients were enrolled (mean age 70.8±11.1 years); 56.3% were male. The mean size of the pulmonary lesions was 36.9±17.4 mm, and the median (interquartile range) distance from the pleura was 15.5 (0.0–30.0) mm. The diagnostic accuracy of EMN-TTNB was 75.0% (21/28), excluding four indeterminate cases. Fourteen patients (50.0%, 14/28) had true-positive and seven patients (25.0%, 7/28) had true-negative lesions. There were no severe adverse reactions such as pneumothorax, respiratory failure, or death, except one case of hemoptysis. CONCLUSIONS: EMN-TTNB under moderate sedation showed an acceptable diagnostic accuracy and good safety profile. The new technology allows physicians to perform percutaneous lung biopsies without the intervention of a radiologist or anesthesiologist.
format Online
Article
Text
id pubmed-10413044
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-104130442023-08-11 Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions Kim, SoJeong Kim, NaYoung Chung, SooJie Kim, JungHyun Hyun, InGyu Choi, JeongHee Lee, HeeSung Transl Lung Cancer Res Original Article BACKGROUND: Novel approaches using virtual computed tomography (CT) guidance, namely electromagnetic navigation transthoracic needle biopsy (EMN-TTNB), enable physicians to perform percutaneous lung biopsies. However, there are very few studies on the clinical experiences of EMN-TTNB, and in previous studies, the procedure was usually performed under deep sedation. This study aimed to determine the diagnostic accuracy and safety of EMN-TTNB under moderate sedation. METHODS: We conducted a retrospective analysis of patients who underwent EMN-TTNB under moderate sedation between May 2021 and November 2022 at Hallym University Dongtan Sacred Heart Hospital in South Korea. Moderate sedation was achieved with midazolam injection in the bronchoscopy room using the Veran SPiNperc EM guidance system (Veran Medical, St Louis, MO, USA). Clinical data were collected by review of medical records, and diagnostic accuracy and safety were calculated. RESULTS: Thirty-two patients were enrolled (mean age 70.8±11.1 years); 56.3% were male. The mean size of the pulmonary lesions was 36.9±17.4 mm, and the median (interquartile range) distance from the pleura was 15.5 (0.0–30.0) mm. The diagnostic accuracy of EMN-TTNB was 75.0% (21/28), excluding four indeterminate cases. Fourteen patients (50.0%, 14/28) had true-positive and seven patients (25.0%, 7/28) had true-negative lesions. There were no severe adverse reactions such as pneumothorax, respiratory failure, or death, except one case of hemoptysis. CONCLUSIONS: EMN-TTNB under moderate sedation showed an acceptable diagnostic accuracy and good safety profile. The new technology allows physicians to perform percutaneous lung biopsies without the intervention of a radiologist or anesthesiologist. AME Publishing Company 2023-07-24 2023-07-31 /pmc/articles/PMC10413044/ /pubmed/37577320 http://dx.doi.org/10.21037/tlcr-23-111 Text en 2023 Translational Lung Cancer Research. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Kim, SoJeong
Kim, NaYoung
Chung, SooJie
Kim, JungHyun
Hyun, InGyu
Choi, JeongHee
Lee, HeeSung
Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions
title Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions
title_full Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions
title_fullStr Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions
title_full_unstemmed Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions
title_short Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions
title_sort diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413044/
https://www.ncbi.nlm.nih.gov/pubmed/37577320
http://dx.doi.org/10.21037/tlcr-23-111
work_keys_str_mv AT kimsojeong diagnosticaccuracyandsafetyofelectromagneticnavigationtransthoracicneedlebiopsyundermoderatesedationforthediagnosisofperipheralpulmonarylesions
AT kimnayoung diagnosticaccuracyandsafetyofelectromagneticnavigationtransthoracicneedlebiopsyundermoderatesedationforthediagnosisofperipheralpulmonarylesions
AT chungsoojie diagnosticaccuracyandsafetyofelectromagneticnavigationtransthoracicneedlebiopsyundermoderatesedationforthediagnosisofperipheralpulmonarylesions
AT kimjunghyun diagnosticaccuracyandsafetyofelectromagneticnavigationtransthoracicneedlebiopsyundermoderatesedationforthediagnosisofperipheralpulmonarylesions
AT hyuningyu diagnosticaccuracyandsafetyofelectromagneticnavigationtransthoracicneedlebiopsyundermoderatesedationforthediagnosisofperipheralpulmonarylesions
AT choijeonghee diagnosticaccuracyandsafetyofelectromagneticnavigationtransthoracicneedlebiopsyundermoderatesedationforthediagnosisofperipheralpulmonarylesions
AT leeheesung diagnosticaccuracyandsafetyofelectromagneticnavigationtransthoracicneedlebiopsyundermoderatesedationforthediagnosisofperipheralpulmonarylesions