Cargando…
Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report
BACKGROUND: Cavotricuspid isthmus pulsed-field ablation has been recently described to be safely performed despite initial reports on coronary arterial spasm while conduction disturbances as a complication of cavotricuspid isthmus ablation are rare and have been reported exclusively for radiofrequen...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413419/ https://www.ncbi.nlm.nih.gov/pubmed/37575541 http://dx.doi.org/10.1093/ehjcr/ytad370 |
_version_ | 1785087125968912384 |
---|---|
author | Andrikopoulos, George Tampakis, Konstantinos Sykiotis, Alexandros Pastromas, Sokratis |
author_facet | Andrikopoulos, George Tampakis, Konstantinos Sykiotis, Alexandros Pastromas, Sokratis |
author_sort | Andrikopoulos, George |
collection | PubMed |
description | BACKGROUND: Cavotricuspid isthmus pulsed-field ablation has been recently described to be safely performed despite initial reports on coronary arterial spasm while conduction disturbances as a complication of cavotricuspid isthmus ablation are rare and have been reported exclusively for radiofrequency catheter ablation. CASE SUMMARY: A 64-year-old female patient with mechanical prosthetic valves underwent atrial fibrillation ablation using the pentaspline pulsed-field ablation catheter. At the end of the uneventful pulmonary vein isolation, an atrial tachycardia depended to the cavotricuspid isthmus occurred. A single pulsed-field application at the cavotricuspid isthmus resulted in right bundle branch block combined with posterior fascicular hemiblock and PR prolongation that resolved spontaneously within 12 h. DISCUSSION: This is the first report of transient conduction disturbances as a complication of cavotricuspid isthmus pulsed-field ablation. Although the underlying mechanism, either single or miscellaneous, was not verified, this case highlights that caution should be taken when the pentaspline pulsed-field ablation catheter is used for cavotricuspid isthmus ablation. |
format | Online Article Text |
id | pubmed-10413419 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-104134192023-08-11 Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report Andrikopoulos, George Tampakis, Konstantinos Sykiotis, Alexandros Pastromas, Sokratis Eur Heart J Case Rep Case Report BACKGROUND: Cavotricuspid isthmus pulsed-field ablation has been recently described to be safely performed despite initial reports on coronary arterial spasm while conduction disturbances as a complication of cavotricuspid isthmus ablation are rare and have been reported exclusively for radiofrequency catheter ablation. CASE SUMMARY: A 64-year-old female patient with mechanical prosthetic valves underwent atrial fibrillation ablation using the pentaspline pulsed-field ablation catheter. At the end of the uneventful pulmonary vein isolation, an atrial tachycardia depended to the cavotricuspid isthmus occurred. A single pulsed-field application at the cavotricuspid isthmus resulted in right bundle branch block combined with posterior fascicular hemiblock and PR prolongation that resolved spontaneously within 12 h. DISCUSSION: This is the first report of transient conduction disturbances as a complication of cavotricuspid isthmus pulsed-field ablation. Although the underlying mechanism, either single or miscellaneous, was not verified, this case highlights that caution should be taken when the pentaspline pulsed-field ablation catheter is used for cavotricuspid isthmus ablation. Oxford University Press 2023-08-02 /pmc/articles/PMC10413419/ /pubmed/37575541 http://dx.doi.org/10.1093/ehjcr/ytad370 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report Andrikopoulos, George Tampakis, Konstantinos Sykiotis, Alexandros Pastromas, Sokratis Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report |
title | Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report |
title_full | Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report |
title_fullStr | Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report |
title_full_unstemmed | Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report |
title_short | Transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report |
title_sort | transient conduction disturbances acutely after pulsed-field cavotricuspid isthmus ablation: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413419/ https://www.ncbi.nlm.nih.gov/pubmed/37575541 http://dx.doi.org/10.1093/ehjcr/ytad370 |
work_keys_str_mv | AT andrikopoulosgeorge transientconductiondisturbancesacutelyafterpulsedfieldcavotricuspidisthmusablationacasereport AT tampakiskonstantinos transientconductiondisturbancesacutelyafterpulsedfieldcavotricuspidisthmusablationacasereport AT sykiotisalexandros transientconductiondisturbancesacutelyafterpulsedfieldcavotricuspidisthmusablationacasereport AT pastromassokratis transientconductiondisturbancesacutelyafterpulsedfieldcavotricuspidisthmusablationacasereport |