Cargando…
Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients
BACKGROUND: Mobile gait sensors represent a compelling tool to objectify the severity of symptoms in patients with idiopathic Parkinson’s disease (iPD), but also to determine the therapeutic benefit of interventions. In particular, parameters of Deep Brain stimulation (DBS) with its short latency co...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413698/ https://www.ncbi.nlm.nih.gov/pubmed/37559161 http://dx.doi.org/10.1186/s42466-023-00263-7 |
_version_ | 1785087190157492224 |
---|---|
author | Mügge, F. Kleinholdermann, U. Heun, A. Ollenschläger, M. Hannink, J. Pedrosa, D. J. |
author_facet | Mügge, F. Kleinholdermann, U. Heun, A. Ollenschläger, M. Hannink, J. Pedrosa, D. J. |
author_sort | Mügge, F. |
collection | PubMed |
description | BACKGROUND: Mobile gait sensors represent a compelling tool to objectify the severity of symptoms in patients with idiopathic Parkinson’s disease (iPD), but also to determine the therapeutic benefit of interventions. In particular, parameters of Deep Brain stimulation (DBS) with its short latency could be accurately assessed using sensor data. This study aimed at gaining insight into gait changes due to different DBS parameters in patients with subthalamic nucleus (STN) DBS. METHODS: An analysis of various gait examinations was performed on 23 of the initially enrolled 27 iPD patients with chronic STN DBS. Stimulation settings were previously adjusted for either amplitude, frequency, or pulse width in a randomised order. A linear mixed effects model was used to analyse changes in gait speed, stride length, and maximum sensor lift. RESULTS: The findings of our study indicate significant improvements in gait speed, stride length, and leg lift measurable with mobile gait sensors under different DBS parameter variations. Notably, we observed positive results at 85 Hz, which proved to be more effective than often applied higher frequencies and that these improvements were traceable across almost all conditions. While pulse widths did produce some improvements in leg lift, they were less well tolerated and had inconsistent effects on some of the gait parameters. Our research suggests that using lower frequencies of DBS may offer a more tolerable and effective approach to enhancing gait in individuals with iPD. CONCLUSIONS: Our results advocate for lower stimulation frequencies for patients who report gait difficulties, especially those who can adapt their DBS settings remotely. They also show that mobile gait sensors could be incorporated into clinical practice in the near future. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s42466-023-00263-7. |
format | Online Article Text |
id | pubmed-10413698 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-104136982023-08-11 Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients Mügge, F. Kleinholdermann, U. Heun, A. Ollenschläger, M. Hannink, J. Pedrosa, D. J. Neurol Res Pract Research Article BACKGROUND: Mobile gait sensors represent a compelling tool to objectify the severity of symptoms in patients with idiopathic Parkinson’s disease (iPD), but also to determine the therapeutic benefit of interventions. In particular, parameters of Deep Brain stimulation (DBS) with its short latency could be accurately assessed using sensor data. This study aimed at gaining insight into gait changes due to different DBS parameters in patients with subthalamic nucleus (STN) DBS. METHODS: An analysis of various gait examinations was performed on 23 of the initially enrolled 27 iPD patients with chronic STN DBS. Stimulation settings were previously adjusted for either amplitude, frequency, or pulse width in a randomised order. A linear mixed effects model was used to analyse changes in gait speed, stride length, and maximum sensor lift. RESULTS: The findings of our study indicate significant improvements in gait speed, stride length, and leg lift measurable with mobile gait sensors under different DBS parameter variations. Notably, we observed positive results at 85 Hz, which proved to be more effective than often applied higher frequencies and that these improvements were traceable across almost all conditions. While pulse widths did produce some improvements in leg lift, they were less well tolerated and had inconsistent effects on some of the gait parameters. Our research suggests that using lower frequencies of DBS may offer a more tolerable and effective approach to enhancing gait in individuals with iPD. CONCLUSIONS: Our results advocate for lower stimulation frequencies for patients who report gait difficulties, especially those who can adapt their DBS settings remotely. They also show that mobile gait sensors could be incorporated into clinical practice in the near future. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s42466-023-00263-7. BioMed Central 2023-08-10 /pmc/articles/PMC10413698/ /pubmed/37559161 http://dx.doi.org/10.1186/s42466-023-00263-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Article Mügge, F. Kleinholdermann, U. Heun, A. Ollenschläger, M. Hannink, J. Pedrosa, D. J. Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients |
title | Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients |
title_full | Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients |
title_fullStr | Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients |
title_full_unstemmed | Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients |
title_short | Subthalamic 85 Hz deep brain stimulation improves walking pace and stride length in Parkinson’s disease patients |
title_sort | subthalamic 85 hz deep brain stimulation improves walking pace and stride length in parkinson’s disease patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413698/ https://www.ncbi.nlm.nih.gov/pubmed/37559161 http://dx.doi.org/10.1186/s42466-023-00263-7 |
work_keys_str_mv | AT muggef subthalamic85hzdeepbrainstimulationimproveswalkingpaceandstridelengthinparkinsonsdiseasepatients AT kleinholdermannu subthalamic85hzdeepbrainstimulationimproveswalkingpaceandstridelengthinparkinsonsdiseasepatients AT heuna subthalamic85hzdeepbrainstimulationimproveswalkingpaceandstridelengthinparkinsonsdiseasepatients AT ollenschlagerm subthalamic85hzdeepbrainstimulationimproveswalkingpaceandstridelengthinparkinsonsdiseasepatients AT hanninkj subthalamic85hzdeepbrainstimulationimproveswalkingpaceandstridelengthinparkinsonsdiseasepatients AT pedrosadj subthalamic85hzdeepbrainstimulationimproveswalkingpaceandstridelengthinparkinsonsdiseasepatients |