Cargando…

Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing

BACKGROUND: This study aimed to compare fused deposition modeling (FDM) and digital light processing (DLP) techniques in terms of dimensional accuracy for printing dental models used for the manufacture of clear dental aligners. MATERIAL/METHODS: Based on the intraoral scan of an adult patient, a se...

Descripción completa

Detalles Bibliográficos
Autores principales: Grzebieluch, Wojciech, Grajzer, Magdalena, Mikulewicz, Marcin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413909/
https://www.ncbi.nlm.nih.gov/pubmed/37533235
http://dx.doi.org/10.12659/MSM.940922
_version_ 1785087233407057920
author Grzebieluch, Wojciech
Grajzer, Magdalena
Mikulewicz, Marcin
author_facet Grzebieluch, Wojciech
Grajzer, Magdalena
Mikulewicz, Marcin
author_sort Grzebieluch, Wojciech
collection PubMed
description BACKGROUND: This study aimed to compare fused deposition modeling (FDM) and digital light processing (DLP) techniques in terms of dimensional accuracy for printing dental models used for the manufacture of clear dental aligners. MATERIAL/METHODS: Based on the intraoral scan of an adult patient, a sequence of 10 aligner models was created using BlueSkyPlan4. The test models (n=30) were fabricated with 2 desktop 3D printers: (DLP) and (FDM) printers. Two groups of samples were created (digitized using a desktop optical scanner). To calculate trueness (n=20) and precision (n=10), printed models were compared to the source files (REF). REF, DLP, and FDM files were superimposed and converted to point clouds. The cloud-to-cloud distances were calculated using CloudCompare software. Using the same algorithm, distortions of models were measured. Data were analyzed using one-way ANOVA and Tukey’s post hoc test. RESULTS: Significant differences were found between the trueness and precision of DLP and FDM groups. The average calculated trueness of DLP and FDM was 0.096 mm (0.021) (P<0.001) and 0.063 mm (0.024) (P<0.001), respectively. The average calculated precision of DLP and FDM was 0.027 mm (0.003) (P<0.001) and 0.036 mm (0.003) (P<0.001), respectively. A widening (0.158 mm [0.089] for DLP and 0.093 mm [0.005] for FDM, P=0.05) and twisting (0.03 mm [0.014] for DLP and 0.043 mm [0.029] for FDM, P=0.05) of the printed models was observed. CONCLUSIONS: Both printers had sufficient precision for aligner models manufacturing. FDM showed a higher trueness and this device can be applied as an alternative to DLP. Polymerization shrinkage is a significant factor in decreasing the trueness of DLP printers.
format Online
Article
Text
id pubmed-10413909
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-104139092023-08-11 Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing Grzebieluch, Wojciech Grajzer, Magdalena Mikulewicz, Marcin Med Sci Monit Article BACKGROUND: This study aimed to compare fused deposition modeling (FDM) and digital light processing (DLP) techniques in terms of dimensional accuracy for printing dental models used for the manufacture of clear dental aligners. MATERIAL/METHODS: Based on the intraoral scan of an adult patient, a sequence of 10 aligner models was created using BlueSkyPlan4. The test models (n=30) were fabricated with 2 desktop 3D printers: (DLP) and (FDM) printers. Two groups of samples were created (digitized using a desktop optical scanner). To calculate trueness (n=20) and precision (n=10), printed models were compared to the source files (REF). REF, DLP, and FDM files were superimposed and converted to point clouds. The cloud-to-cloud distances were calculated using CloudCompare software. Using the same algorithm, distortions of models were measured. Data were analyzed using one-way ANOVA and Tukey’s post hoc test. RESULTS: Significant differences were found between the trueness and precision of DLP and FDM groups. The average calculated trueness of DLP and FDM was 0.096 mm (0.021) (P<0.001) and 0.063 mm (0.024) (P<0.001), respectively. The average calculated precision of DLP and FDM was 0.027 mm (0.003) (P<0.001) and 0.036 mm (0.003) (P<0.001), respectively. A widening (0.158 mm [0.089] for DLP and 0.093 mm [0.005] for FDM, P=0.05) and twisting (0.03 mm [0.014] for DLP and 0.043 mm [0.029] for FDM, P=0.05) of the printed models was observed. CONCLUSIONS: Both printers had sufficient precision for aligner models manufacturing. FDM showed a higher trueness and this device can be applied as an alternative to DLP. Polymerization shrinkage is a significant factor in decreasing the trueness of DLP printers. International Scientific Literature, Inc. 2023-08-03 /pmc/articles/PMC10413909/ /pubmed/37533235 http://dx.doi.org/10.12659/MSM.940922 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Article
Grzebieluch, Wojciech
Grajzer, Magdalena
Mikulewicz, Marcin
Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing
title Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing
title_full Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing
title_fullStr Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing
title_full_unstemmed Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing
title_short Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing
title_sort comparative analysis of fused deposition modeling and digital light processing techniques for dimensional accuracy in clear aligner manufacturing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413909/
https://www.ncbi.nlm.nih.gov/pubmed/37533235
http://dx.doi.org/10.12659/MSM.940922
work_keys_str_mv AT grzebieluchwojciech comparativeanalysisoffuseddepositionmodelinganddigitallightprocessingtechniquesfordimensionalaccuracyinclearalignermanufacturing
AT grajzermagdalena comparativeanalysisoffuseddepositionmodelinganddigitallightprocessingtechniquesfordimensionalaccuracyinclearalignermanufacturing
AT mikulewiczmarcin comparativeanalysisoffuseddepositionmodelinganddigitallightprocessingtechniquesfordimensionalaccuracyinclearalignermanufacturing