Cargando…
Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing
BACKGROUND: This study aimed to compare fused deposition modeling (FDM) and digital light processing (DLP) techniques in terms of dimensional accuracy for printing dental models used for the manufacture of clear dental aligners. MATERIAL/METHODS: Based on the intraoral scan of an adult patient, a se...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413909/ https://www.ncbi.nlm.nih.gov/pubmed/37533235 http://dx.doi.org/10.12659/MSM.940922 |
_version_ | 1785087233407057920 |
---|---|
author | Grzebieluch, Wojciech Grajzer, Magdalena Mikulewicz, Marcin |
author_facet | Grzebieluch, Wojciech Grajzer, Magdalena Mikulewicz, Marcin |
author_sort | Grzebieluch, Wojciech |
collection | PubMed |
description | BACKGROUND: This study aimed to compare fused deposition modeling (FDM) and digital light processing (DLP) techniques in terms of dimensional accuracy for printing dental models used for the manufacture of clear dental aligners. MATERIAL/METHODS: Based on the intraoral scan of an adult patient, a sequence of 10 aligner models was created using BlueSkyPlan4. The test models (n=30) were fabricated with 2 desktop 3D printers: (DLP) and (FDM) printers. Two groups of samples were created (digitized using a desktop optical scanner). To calculate trueness (n=20) and precision (n=10), printed models were compared to the source files (REF). REF, DLP, and FDM files were superimposed and converted to point clouds. The cloud-to-cloud distances were calculated using CloudCompare software. Using the same algorithm, distortions of models were measured. Data were analyzed using one-way ANOVA and Tukey’s post hoc test. RESULTS: Significant differences were found between the trueness and precision of DLP and FDM groups. The average calculated trueness of DLP and FDM was 0.096 mm (0.021) (P<0.001) and 0.063 mm (0.024) (P<0.001), respectively. The average calculated precision of DLP and FDM was 0.027 mm (0.003) (P<0.001) and 0.036 mm (0.003) (P<0.001), respectively. A widening (0.158 mm [0.089] for DLP and 0.093 mm [0.005] for FDM, P=0.05) and twisting (0.03 mm [0.014] for DLP and 0.043 mm [0.029] for FDM, P=0.05) of the printed models was observed. CONCLUSIONS: Both printers had sufficient precision for aligner models manufacturing. FDM showed a higher trueness and this device can be applied as an alternative to DLP. Polymerization shrinkage is a significant factor in decreasing the trueness of DLP printers. |
format | Online Article Text |
id | pubmed-10413909 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-104139092023-08-11 Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing Grzebieluch, Wojciech Grajzer, Magdalena Mikulewicz, Marcin Med Sci Monit Article BACKGROUND: This study aimed to compare fused deposition modeling (FDM) and digital light processing (DLP) techniques in terms of dimensional accuracy for printing dental models used for the manufacture of clear dental aligners. MATERIAL/METHODS: Based on the intraoral scan of an adult patient, a sequence of 10 aligner models was created using BlueSkyPlan4. The test models (n=30) were fabricated with 2 desktop 3D printers: (DLP) and (FDM) printers. Two groups of samples were created (digitized using a desktop optical scanner). To calculate trueness (n=20) and precision (n=10), printed models were compared to the source files (REF). REF, DLP, and FDM files were superimposed and converted to point clouds. The cloud-to-cloud distances were calculated using CloudCompare software. Using the same algorithm, distortions of models were measured. Data were analyzed using one-way ANOVA and Tukey’s post hoc test. RESULTS: Significant differences were found between the trueness and precision of DLP and FDM groups. The average calculated trueness of DLP and FDM was 0.096 mm (0.021) (P<0.001) and 0.063 mm (0.024) (P<0.001), respectively. The average calculated precision of DLP and FDM was 0.027 mm (0.003) (P<0.001) and 0.036 mm (0.003) (P<0.001), respectively. A widening (0.158 mm [0.089] for DLP and 0.093 mm [0.005] for FDM, P=0.05) and twisting (0.03 mm [0.014] for DLP and 0.043 mm [0.029] for FDM, P=0.05) of the printed models was observed. CONCLUSIONS: Both printers had sufficient precision for aligner models manufacturing. FDM showed a higher trueness and this device can be applied as an alternative to DLP. Polymerization shrinkage is a significant factor in decreasing the trueness of DLP printers. International Scientific Literature, Inc. 2023-08-03 /pmc/articles/PMC10413909/ /pubmed/37533235 http://dx.doi.org/10.12659/MSM.940922 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Article Grzebieluch, Wojciech Grajzer, Magdalena Mikulewicz, Marcin Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing |
title | Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing |
title_full | Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing |
title_fullStr | Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing |
title_full_unstemmed | Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing |
title_short | Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing |
title_sort | comparative analysis of fused deposition modeling and digital light processing techniques for dimensional accuracy in clear aligner manufacturing |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10413909/ https://www.ncbi.nlm.nih.gov/pubmed/37533235 http://dx.doi.org/10.12659/MSM.940922 |
work_keys_str_mv | AT grzebieluchwojciech comparativeanalysisoffuseddepositionmodelinganddigitallightprocessingtechniquesfordimensionalaccuracyinclearalignermanufacturing AT grajzermagdalena comparativeanalysisoffuseddepositionmodelinganddigitallightprocessingtechniquesfordimensionalaccuracyinclearalignermanufacturing AT mikulewiczmarcin comparativeanalysisoffuseddepositionmodelinganddigitallightprocessingtechniquesfordimensionalaccuracyinclearalignermanufacturing |