Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator
The DARWIN observatory is a proposed next-generation experiment with 40 tonnes of liquid xenon as an active target in a time projection chamber. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demo...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10415528/ https://www.ncbi.nlm.nih.gov/pubmed/37576939 http://dx.doi.org/10.1140/epjc/s10052-023-11823-1 |
_version_ | 1785087561333473280 |
---|---|
author | Baudis, L. Biondi, Y. Bismark, A. Cimental Chávez, A. P. Cuenca-García, J. J. Franchi, J. Galloway, M. Girard, F. Peres, R. Ramírez García, D. Sanchez-Lucas, P. Thieme, K. Wittweg, C. |
author_facet | Baudis, L. Biondi, Y. Bismark, A. Cimental Chávez, A. P. Cuenca-García, J. J. Franchi, J. Galloway, M. Girard, F. Peres, R. Ramírez García, D. Sanchez-Lucas, P. Thieme, K. Wittweg, C. |
author_sort | Baudis, L. |
collection | PubMed |
description | The DARWIN observatory is a proposed next-generation experiment with 40 tonnes of liquid xenon as an active target in a time projection chamber. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demonstrator for the DARWIN experiment at the University of Zurich. Here, we present the first results from a several-months run with [Formula: see text] of xenon and electron drift lifetime and transport measurements with a [Formula: see text] tall purity monitor immersed in the cryogenic liquid. After [Formula: see text] of continuous purification, the electron lifetime reached a value of [Formula: see text] . We measured the drift velocity of electrons for electric fields in the range (25–75) V/cm, and found values consistent with previous measurements. We also calculated the longitudinal diffusion constant of the electron cloud in the same field range, and compared with previous data, as well as with predictions from an empirical model. |
format | Online Article Text |
id | pubmed-10415528 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-104155282023-08-12 Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator Baudis, L. Biondi, Y. Bismark, A. Cimental Chávez, A. P. Cuenca-García, J. J. Franchi, J. Galloway, M. Girard, F. Peres, R. Ramírez García, D. Sanchez-Lucas, P. Thieme, K. Wittweg, C. Eur Phys J C Part Fields Regular Article - Experimental Physics The DARWIN observatory is a proposed next-generation experiment with 40 tonnes of liquid xenon as an active target in a time projection chamber. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demonstrator for the DARWIN experiment at the University of Zurich. Here, we present the first results from a several-months run with [Formula: see text] of xenon and electron drift lifetime and transport measurements with a [Formula: see text] tall purity monitor immersed in the cryogenic liquid. After [Formula: see text] of continuous purification, the electron lifetime reached a value of [Formula: see text] . We measured the drift velocity of electrons for electric fields in the range (25–75) V/cm, and found values consistent with previous measurements. We also calculated the longitudinal diffusion constant of the electron cloud in the same field range, and compared with previous data, as well as with predictions from an empirical model. Springer Berlin Heidelberg 2023-08-10 2023 /pmc/articles/PMC10415528/ /pubmed/37576939 http://dx.doi.org/10.1140/epjc/s10052-023-11823-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . Funded by SCOAP3. SCOAP3 supports the goals of the International Year of Basic Sciences for Sustainable Development. |
spellingShingle | Regular Article - Experimental Physics Baudis, L. Biondi, Y. Bismark, A. Cimental Chávez, A. P. Cuenca-García, J. J. Franchi, J. Galloway, M. Girard, F. Peres, R. Ramírez García, D. Sanchez-Lucas, P. Thieme, K. Wittweg, C. Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator |
title | Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator |
title_full | Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator |
title_fullStr | Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator |
title_full_unstemmed | Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator |
title_short | Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator |
title_sort | electron transport measurements in liquid xenon with xenoscope, a large-scale darwin demonstrator |
topic | Regular Article - Experimental Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10415528/ https://www.ncbi.nlm.nih.gov/pubmed/37576939 http://dx.doi.org/10.1140/epjc/s10052-023-11823-1 |
work_keys_str_mv | AT baudisl electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT biondiy electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT bismarka electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT cimentalchavezap electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT cuencagarciajj electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT franchij electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT gallowaym electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT girardf electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT peresr electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT ramirezgarciad electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT sanchezlucasp electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT thiemek electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator AT wittwegc electrontransportmeasurementsinliquidxenonwithxenoscopealargescaledarwindemonstrator |