Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation

In recent years, higher requirements have been placed on the response characteristics of X-ray detectors in the field of medical diagnostic imaging. Due to this, high sensitivity, high attenuation coefficient and low cost detection materials need to be developed. In this paper, the geometric model o...

Descripción completa

Detalles Bibliográficos
Autores principales: Qin, Feng, Zhao, Rui, Zhu, Wei Feng, Deng, Ning Qin, Jiao, Zhi Wei, Tang, Xian Qiang, Wu, Jin Jie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10415924/
https://www.ncbi.nlm.nih.gov/pubmed/37576217
http://dx.doi.org/10.1016/j.heliyon.2023.e18875
_version_ 1785087655810170880
author Qin, Feng
Zhao, Rui
Zhu, Wei Feng
Deng, Ning Qin
Jiao, Zhi Wei
Tang, Xian Qiang
Wu, Jin Jie
author_facet Qin, Feng
Zhao, Rui
Zhu, Wei Feng
Deng, Ning Qin
Jiao, Zhi Wei
Tang, Xian Qiang
Wu, Jin Jie
author_sort Qin, Feng
collection PubMed
description In recent years, higher requirements have been placed on the response characteristics of X-ray detectors in the field of medical diagnostic imaging. Due to this, high sensitivity, high attenuation coefficient and low cost detection materials need to be developed. In this paper, the geometric model of a detector was established by Geant4 code. The absorption efficiency and mass attenuation coefficient of MAPbBr(3) crystals were calculated in the energy range of 30 keV to 100 keV. Compared with the mass attenuation coefficient of the NIST database, the deviation was within 1.39%. The signal charge number and detection sensitivity of the X-ray interaction with the MAPbBr(3) crystal ware calculated. Compared with the CdTe crystal and α-Se, the MAPbBr(3) crystal still had a larger detection sensitivity under a smaller applied electric field, which was approximately 9 times higher than that of α-Se. This result indicated that the detection sensitivity could be greatly improved by using a high atomic number and high charge mobility-lifetime product. Based on the simulation results, the 2 mm thick MAPbBr(3) crystal exhibited the highest detection sensitivity at 60 keV X-rays, which was in agreement with the experimental results.
format Online
Article
Text
id pubmed-10415924
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104159242023-08-12 Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation Qin, Feng Zhao, Rui Zhu, Wei Feng Deng, Ning Qin Jiao, Zhi Wei Tang, Xian Qiang Wu, Jin Jie Heliyon Research Article In recent years, higher requirements have been placed on the response characteristics of X-ray detectors in the field of medical diagnostic imaging. Due to this, high sensitivity, high attenuation coefficient and low cost detection materials need to be developed. In this paper, the geometric model of a detector was established by Geant4 code. The absorption efficiency and mass attenuation coefficient of MAPbBr(3) crystals were calculated in the energy range of 30 keV to 100 keV. Compared with the mass attenuation coefficient of the NIST database, the deviation was within 1.39%. The signal charge number and detection sensitivity of the X-ray interaction with the MAPbBr(3) crystal ware calculated. Compared with the CdTe crystal and α-Se, the MAPbBr(3) crystal still had a larger detection sensitivity under a smaller applied electric field, which was approximately 9 times higher than that of α-Se. This result indicated that the detection sensitivity could be greatly improved by using a high atomic number and high charge mobility-lifetime product. Based on the simulation results, the 2 mm thick MAPbBr(3) crystal exhibited the highest detection sensitivity at 60 keV X-rays, which was in agreement with the experimental results. Elsevier 2023-08-01 /pmc/articles/PMC10415924/ /pubmed/37576217 http://dx.doi.org/10.1016/j.heliyon.2023.e18875 Text en © 2023 The Authors. Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Qin, Feng
Zhao, Rui
Zhu, Wei Feng
Deng, Ning Qin
Jiao, Zhi Wei
Tang, Xian Qiang
Wu, Jin Jie
Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation
title Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation
title_full Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation
title_fullStr Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation
title_full_unstemmed Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation
title_short Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation
title_sort response characteristics of mapbbr(3) direct conversion x-ray detectors based on measurements and monte carlo simulation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10415924/
https://www.ncbi.nlm.nih.gov/pubmed/37576217
http://dx.doi.org/10.1016/j.heliyon.2023.e18875
work_keys_str_mv AT qinfeng responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation
AT zhaorui responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation
AT zhuweifeng responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation
AT dengningqin responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation
AT jiaozhiwei responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation
AT tangxianqiang responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation
AT wujinjie responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation