Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation
In recent years, higher requirements have been placed on the response characteristics of X-ray detectors in the field of medical diagnostic imaging. Due to this, high sensitivity, high attenuation coefficient and low cost detection materials need to be developed. In this paper, the geometric model o...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10415924/ https://www.ncbi.nlm.nih.gov/pubmed/37576217 http://dx.doi.org/10.1016/j.heliyon.2023.e18875 |
_version_ | 1785087655810170880 |
---|---|
author | Qin, Feng Zhao, Rui Zhu, Wei Feng Deng, Ning Qin Jiao, Zhi Wei Tang, Xian Qiang Wu, Jin Jie |
author_facet | Qin, Feng Zhao, Rui Zhu, Wei Feng Deng, Ning Qin Jiao, Zhi Wei Tang, Xian Qiang Wu, Jin Jie |
author_sort | Qin, Feng |
collection | PubMed |
description | In recent years, higher requirements have been placed on the response characteristics of X-ray detectors in the field of medical diagnostic imaging. Due to this, high sensitivity, high attenuation coefficient and low cost detection materials need to be developed. In this paper, the geometric model of a detector was established by Geant4 code. The absorption efficiency and mass attenuation coefficient of MAPbBr(3) crystals were calculated in the energy range of 30 keV to 100 keV. Compared with the mass attenuation coefficient of the NIST database, the deviation was within 1.39%. The signal charge number and detection sensitivity of the X-ray interaction with the MAPbBr(3) crystal ware calculated. Compared with the CdTe crystal and α-Se, the MAPbBr(3) crystal still had a larger detection sensitivity under a smaller applied electric field, which was approximately 9 times higher than that of α-Se. This result indicated that the detection sensitivity could be greatly improved by using a high atomic number and high charge mobility-lifetime product. Based on the simulation results, the 2 mm thick MAPbBr(3) crystal exhibited the highest detection sensitivity at 60 keV X-rays, which was in agreement with the experimental results. |
format | Online Article Text |
id | pubmed-10415924 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-104159242023-08-12 Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation Qin, Feng Zhao, Rui Zhu, Wei Feng Deng, Ning Qin Jiao, Zhi Wei Tang, Xian Qiang Wu, Jin Jie Heliyon Research Article In recent years, higher requirements have been placed on the response characteristics of X-ray detectors in the field of medical diagnostic imaging. Due to this, high sensitivity, high attenuation coefficient and low cost detection materials need to be developed. In this paper, the geometric model of a detector was established by Geant4 code. The absorption efficiency and mass attenuation coefficient of MAPbBr(3) crystals were calculated in the energy range of 30 keV to 100 keV. Compared with the mass attenuation coefficient of the NIST database, the deviation was within 1.39%. The signal charge number and detection sensitivity of the X-ray interaction with the MAPbBr(3) crystal ware calculated. Compared with the CdTe crystal and α-Se, the MAPbBr(3) crystal still had a larger detection sensitivity under a smaller applied electric field, which was approximately 9 times higher than that of α-Se. This result indicated that the detection sensitivity could be greatly improved by using a high atomic number and high charge mobility-lifetime product. Based on the simulation results, the 2 mm thick MAPbBr(3) crystal exhibited the highest detection sensitivity at 60 keV X-rays, which was in agreement with the experimental results. Elsevier 2023-08-01 /pmc/articles/PMC10415924/ /pubmed/37576217 http://dx.doi.org/10.1016/j.heliyon.2023.e18875 Text en © 2023 The Authors. Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Qin, Feng Zhao, Rui Zhu, Wei Feng Deng, Ning Qin Jiao, Zhi Wei Tang, Xian Qiang Wu, Jin Jie Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation |
title | Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation |
title_full | Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation |
title_fullStr | Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation |
title_full_unstemmed | Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation |
title_short | Response characteristics of MAPbBr(3) direct conversion X-ray detectors based on measurements and Monte Carlo simulation |
title_sort | response characteristics of mapbbr(3) direct conversion x-ray detectors based on measurements and monte carlo simulation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10415924/ https://www.ncbi.nlm.nih.gov/pubmed/37576217 http://dx.doi.org/10.1016/j.heliyon.2023.e18875 |
work_keys_str_mv | AT qinfeng responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation AT zhaorui responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation AT zhuweifeng responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation AT dengningqin responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation AT jiaozhiwei responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation AT tangxianqiang responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation AT wujinjie responsecharacteristicsofmapbbr3directconversionxraydetectorsbasedonmeasurementsandmontecarlosimulation |