Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil

PURPOSE: To derive a formula for accurate axial length (AL) assessment using routine ultrasound in silicone oil-filled eyes, where optical biometry is unavailable or not possible. METHODS: This was a prospective, consecutive, nonrandomized study of 50 eyes of 50 patients conducted in a tertiary care...

Descripción completa

Detalles Bibliográficos
Autores principales: Kapoor, Monika, Venkatesh, Pradeep, Chawla, Rohan, Temkar, Shreyas, Aggarwal, Esha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10417960/
https://www.ncbi.nlm.nih.gov/pubmed/37322662
http://dx.doi.org/10.4103/ijo.IJO_2187_22
_version_ 1785088163907108864
author Kapoor, Monika
Venkatesh, Pradeep
Chawla, Rohan
Temkar, Shreyas
Aggarwal, Esha
author_facet Kapoor, Monika
Venkatesh, Pradeep
Chawla, Rohan
Temkar, Shreyas
Aggarwal, Esha
author_sort Kapoor, Monika
collection PubMed
description PURPOSE: To derive a formula for accurate axial length (AL) assessment using routine ultrasound in silicone oil-filled eyes, where optical biometry is unavailable or not possible. METHODS: This was a prospective, consecutive, nonrandomized study of 50 eyes of 50 patients conducted in a tertiary care hospital in North India. AL measurements were taken using both manual A-scan and IOL master, both in silicone oil-filled status and 3 weeks after silicone oil removal. A correction factor of 0.7 was used for AL adjustment in oil-filled eyes. The corrected AL (cAL) was compared with IOL master values in oil-filled eyes. Agreement analysis was carried out using Bland Altman plot. Linear regression analysis was done using uncorrected manual AL to find a new equation. Data was analyzed using Stata 14. A P value <0.05 was taken as significant. RESULTS: The study included 40 males and 10 females, with an age range of 6–83 years (mean 41.9 years). The mean AL of the oil-filled eye as measured by manual A-scan was 31.76 mm ± 3.09 and by IOL master was 24.7 mm ± 1.74. Linear regression analysis was performed in randomly selected 35 eyes of the observed data to obtain a new equation: predicted AL (PAL) = 14 + 0.3 × manual AL. The mean difference between PAL and optically measured AL with silicone oil in situ was 0.98 ± 1.67. CONCLUSION: We propose a new formula for better prediction of the correct AL in silicone oil-filled eyes using ultrasound-based AL measurement.
format Online
Article
Text
id pubmed-10417960
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-104179602023-08-12 Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil Kapoor, Monika Venkatesh, Pradeep Chawla, Rohan Temkar, Shreyas Aggarwal, Esha Indian J Ophthalmol Original Article PURPOSE: To derive a formula for accurate axial length (AL) assessment using routine ultrasound in silicone oil-filled eyes, where optical biometry is unavailable or not possible. METHODS: This was a prospective, consecutive, nonrandomized study of 50 eyes of 50 patients conducted in a tertiary care hospital in North India. AL measurements were taken using both manual A-scan and IOL master, both in silicone oil-filled status and 3 weeks after silicone oil removal. A correction factor of 0.7 was used for AL adjustment in oil-filled eyes. The corrected AL (cAL) was compared with IOL master values in oil-filled eyes. Agreement analysis was carried out using Bland Altman plot. Linear regression analysis was done using uncorrected manual AL to find a new equation. Data was analyzed using Stata 14. A P value <0.05 was taken as significant. RESULTS: The study included 40 males and 10 females, with an age range of 6–83 years (mean 41.9 years). The mean AL of the oil-filled eye as measured by manual A-scan was 31.76 mm ± 3.09 and by IOL master was 24.7 mm ± 1.74. Linear regression analysis was performed in randomly selected 35 eyes of the observed data to obtain a new equation: predicted AL (PAL) = 14 + 0.3 × manual AL. The mean difference between PAL and optically measured AL with silicone oil in situ was 0.98 ± 1.67. CONCLUSION: We propose a new formula for better prediction of the correct AL in silicone oil-filled eyes using ultrasound-based AL measurement. Wolters Kluwer - Medknow 2023-06 2023-06-14 /pmc/articles/PMC10417960/ /pubmed/37322662 http://dx.doi.org/10.4103/ijo.IJO_2187_22 Text en Copyright: © 2023 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kapoor, Monika
Venkatesh, Pradeep
Chawla, Rohan
Temkar, Shreyas
Aggarwal, Esha
Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil
title Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil
title_full Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil
title_fullStr Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil
title_full_unstemmed Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil
title_short Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil
title_sort simplifying biometry in oil-filled eyes: a novel formula for axial length calculation in eyes with 1000 cst silicone oil
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10417960/
https://www.ncbi.nlm.nih.gov/pubmed/37322662
http://dx.doi.org/10.4103/ijo.IJO_2187_22
work_keys_str_mv AT kapoormonika simplifyingbiometryinoilfilledeyesanovelformulaforaxiallengthcalculationineyeswith1000cstsiliconeoil
AT venkateshpradeep simplifyingbiometryinoilfilledeyesanovelformulaforaxiallengthcalculationineyeswith1000cstsiliconeoil
AT chawlarohan simplifyingbiometryinoilfilledeyesanovelformulaforaxiallengthcalculationineyeswith1000cstsiliconeoil
AT temkarshreyas simplifyingbiometryinoilfilledeyesanovelformulaforaxiallengthcalculationineyeswith1000cstsiliconeoil
AT aggarwalesha simplifyingbiometryinoilfilledeyesanovelformulaforaxiallengthcalculationineyeswith1000cstsiliconeoil