Tunable Non-Enzymatic Glucose Electrochemical Sensing Based on the Ni/Co Bimetallic MOFs
Constructing high-performance glucose sensors is of great significance for the prevention and diagnosis of diabetes, and the key is to develop new sensitive materials. In this paper, a series of Ni(2)Co(1)-L MOFs (L = H(2)BPDC: 4,4′-biphenyldicarboxylic acid; H(2)NDC: 2,6-naphthalenedicarboxylic aci...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10420269/ https://www.ncbi.nlm.nih.gov/pubmed/37570619 http://dx.doi.org/10.3390/molecules28155649 |
Sumario: | Constructing high-performance glucose sensors is of great significance for the prevention and diagnosis of diabetes, and the key is to develop new sensitive materials. In this paper, a series of Ni(2)Co(1)-L MOFs (L = H(2)BPDC: 4,4′-biphenyldicarboxylic acid; H(2)NDC: 2,6-naphthalenedicarboxylic acid; H(2)BDC: 1,4-benzenedicarboxylic acid) were synthesized by a room temperature stirring method. The effects of metal centers and ligands on the structure, compositions, electrochemical properties of the obtained Ni(2)Co(1)-L MOFs were characterized, indicating the successful preparation of layered MOFs with different sizes, stacking degrees, electrochemical active areas, numbers of exposed active sites, and glucose catalytic activity. Among them, Ni(2)Co(1)-BDC exhibits a relatively thin and homogeneous plate-like morphology, and the Ni(2)Co(1)-BDC modified glassy carbon electrode (Ni(2)Co(1)-BDC/GCE) has the highest electrochemical performance. Furthermore, the mechanism of the enhanced glucose oxidation signal was investigated. It was shown that glucose has a higher electron transfer capacity and a larger apparent catalytic rate constant on the Ni(2)Co(1)-BDC/GCE surface. Therefore, tunable non-enzymatic glucose electrochemical sensing was carried out by regulating the metal centers and ligands. As a result, a high-sensitivity enzyme-free glucose sensing platform was successfully constructed based on the Ni(2)Co(1)-BDC/GCE, which has a wide linear range of 0.5–2899.5 μM, a low detection limit of 0.29 μM (S/N = 3), and a high sensitivity of 3925.3 μA mM(−1) cm(−2). Much more importantly, it was also successfully applied to the determination of glucose in human serum with satisfactory results, demonstrating its potential for glucose detection in real samples. |
---|