Cargando…

Detection of Sarcopenia in Patients with Liver Cirrhosis Using the Bioelectrical Impedance Analysis

Bioelectrical impedance analysis (BIA) is a body composition assessment method. We aimed to determine its accuracy in the detection of sarcopenia in patients with liver cirrhosis (LC), using skeletal muscle index (SMI) at the level of third lumbar vertebra (L3-SMI) obtained using multislice computed...

Descripción completa

Detalles Bibliográficos
Autores principales: Bozic, Dorotea, Grgurevic, Ivica, Mamic, Bisera, Capkun, Vesna, Bilandzic-Ivisic, Josipa, Ivanovic, Tomislav, Bozic, Ivona, Zaja, Ivan, Podrug, Kristian, Puljiz, Zeljko, Perko, Zdravko, Mikolasevic, Ivana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421520/
https://www.ncbi.nlm.nih.gov/pubmed/37571273
http://dx.doi.org/10.3390/nu15153335
_version_ 1785089000862646272
author Bozic, Dorotea
Grgurevic, Ivica
Mamic, Bisera
Capkun, Vesna
Bilandzic-Ivisic, Josipa
Ivanovic, Tomislav
Bozic, Ivona
Zaja, Ivan
Podrug, Kristian
Puljiz, Zeljko
Perko, Zdravko
Mikolasevic, Ivana
author_facet Bozic, Dorotea
Grgurevic, Ivica
Mamic, Bisera
Capkun, Vesna
Bilandzic-Ivisic, Josipa
Ivanovic, Tomislav
Bozic, Ivona
Zaja, Ivan
Podrug, Kristian
Puljiz, Zeljko
Perko, Zdravko
Mikolasevic, Ivana
author_sort Bozic, Dorotea
collection PubMed
description Bioelectrical impedance analysis (BIA) is a body composition assessment method. We aimed to determine its accuracy in the detection of sarcopenia in patients with liver cirrhosis (LC), using skeletal muscle index (SMI) at the level of third lumbar vertebra (L3-SMI) obtained using multislice computed tomography as the reference method. Patients with LC were enrolled in the period October 2019–March 2022 and follow-ups were conducted until January 2023. Their BIA parameters were compared against L3-SMI, and BIA cut-off values were proposed using AUROC analysis. Patients underwent outcome analysis based on obtained clinical characteristics. A total of 106 patients were included. We found a fair correlation between BIA parameters with the L3-SMI. We determined cut-off values of ≤11.1 kg/m(2) for BIA-SMI (Se 73%, Sp 66%, AUROC 0.737, p < 0.001) and ≤5.05° for phase angle (PA) (Se 79%, Sp 60%, AUROC 0.762, p < 0.001) in the detection of sarcopenia. The relative risk of death was 2.2 times higher in patients with skeletal muscle mass (SMM) ≤ 36.5 kg. SMM was significantly associated with outcome in Kaplan–Meier analysis. This non-invasive and simple method that showed fair performances and a very good outcome prediction could provide for the unmet need for fast and affordable detection of sarcopenia in patients with LC and should be further evaluated.
format Online
Article
Text
id pubmed-10421520
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104215202023-08-12 Detection of Sarcopenia in Patients with Liver Cirrhosis Using the Bioelectrical Impedance Analysis Bozic, Dorotea Grgurevic, Ivica Mamic, Bisera Capkun, Vesna Bilandzic-Ivisic, Josipa Ivanovic, Tomislav Bozic, Ivona Zaja, Ivan Podrug, Kristian Puljiz, Zeljko Perko, Zdravko Mikolasevic, Ivana Nutrients Article Bioelectrical impedance analysis (BIA) is a body composition assessment method. We aimed to determine its accuracy in the detection of sarcopenia in patients with liver cirrhosis (LC), using skeletal muscle index (SMI) at the level of third lumbar vertebra (L3-SMI) obtained using multislice computed tomography as the reference method. Patients with LC were enrolled in the period October 2019–March 2022 and follow-ups were conducted until January 2023. Their BIA parameters were compared against L3-SMI, and BIA cut-off values were proposed using AUROC analysis. Patients underwent outcome analysis based on obtained clinical characteristics. A total of 106 patients were included. We found a fair correlation between BIA parameters with the L3-SMI. We determined cut-off values of ≤11.1 kg/m(2) for BIA-SMI (Se 73%, Sp 66%, AUROC 0.737, p < 0.001) and ≤5.05° for phase angle (PA) (Se 79%, Sp 60%, AUROC 0.762, p < 0.001) in the detection of sarcopenia. The relative risk of death was 2.2 times higher in patients with skeletal muscle mass (SMM) ≤ 36.5 kg. SMM was significantly associated with outcome in Kaplan–Meier analysis. This non-invasive and simple method that showed fair performances and a very good outcome prediction could provide for the unmet need for fast and affordable detection of sarcopenia in patients with LC and should be further evaluated. MDPI 2023-07-27 /pmc/articles/PMC10421520/ /pubmed/37571273 http://dx.doi.org/10.3390/nu15153335 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bozic, Dorotea
Grgurevic, Ivica
Mamic, Bisera
Capkun, Vesna
Bilandzic-Ivisic, Josipa
Ivanovic, Tomislav
Bozic, Ivona
Zaja, Ivan
Podrug, Kristian
Puljiz, Zeljko
Perko, Zdravko
Mikolasevic, Ivana
Detection of Sarcopenia in Patients with Liver Cirrhosis Using the Bioelectrical Impedance Analysis
title Detection of Sarcopenia in Patients with Liver Cirrhosis Using the Bioelectrical Impedance Analysis
title_full Detection of Sarcopenia in Patients with Liver Cirrhosis Using the Bioelectrical Impedance Analysis
title_fullStr Detection of Sarcopenia in Patients with Liver Cirrhosis Using the Bioelectrical Impedance Analysis
title_full_unstemmed Detection of Sarcopenia in Patients with Liver Cirrhosis Using the Bioelectrical Impedance Analysis
title_short Detection of Sarcopenia in Patients with Liver Cirrhosis Using the Bioelectrical Impedance Analysis
title_sort detection of sarcopenia in patients with liver cirrhosis using the bioelectrical impedance analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421520/
https://www.ncbi.nlm.nih.gov/pubmed/37571273
http://dx.doi.org/10.3390/nu15153335
work_keys_str_mv AT bozicdorotea detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT grgurevicivica detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT mamicbisera detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT capkunvesna detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT bilandzicivisicjosipa detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT ivanovictomislav detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT bozicivona detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT zajaivan detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT podrugkristian detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT puljizzeljko detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT perkozdravko detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis
AT mikolasevicivana detectionofsarcopeniainpatientswithlivercirrhosisusingthebioelectricalimpedanceanalysis