The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery

After surgery for ovarian cancer or colorectal cancer, residual tumors are left around. A practical way to treat residual tumors is to destroy them with heat by injecting high-temperature drugs into the abdominal cavity. The injected medicinal substances are induced to flow out of the abdominal cavi...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoon, Kicheol, Lee, Sangyun, Lee, Tae-Hyeon, Kim, Kwang Gi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422214/
https://www.ncbi.nlm.nih.gov/pubmed/37571507
http://dx.doi.org/10.3390/s23156722
_version_ 1785089149257121792
author Yoon, Kicheol
Lee, Sangyun
Lee, Tae-Hyeon
Kim, Kwang Gi
author_facet Yoon, Kicheol
Lee, Sangyun
Lee, Tae-Hyeon
Kim, Kwang Gi
author_sort Yoon, Kicheol
collection PubMed
description After surgery for ovarian cancer or colorectal cancer, residual tumors are left around. A practical way to treat residual tumors is to destroy them with heat by injecting high-temperature drugs into the abdominal cavity. The injected medicinal substances are induced to flow out of the abdominal cavity; then, the spilled drug flows back into the abdominal cavity through feedback. During this process, the heat starts to decrease; thus, the treatment performance reduces. To overcome this problem, this study compares and assesses the temperature needed to maintain the heat for treatment and transmits a command signal to the heat exchanger through a look-up table (LUT). When the temperature decreases during the circulation of medications leaking out of the abdominal cavity, the LUT transmits a control signal (T(p)) to the heat exchanger, which increases or vice versa. However, if the temperature (T(o)) is within the treatment range, the LUT sends a T(s) signal to the heat exchanger. This principle generates a pulse signal for the temperature difference (T(dif)) in TC by comparing and determining the temperature (T(o)) of the substance flowing out of the abdominal cavity with the reference temperature (T(ref)) through the temperature comparator (TC). At this time, if the signal is 41 °C or less, the LUT generates (heats) a T(p) signal so that the temperature of the heat exchanger can be maintained in the range of 41 °C to 43 °C. If the T(dif) is 44 °C or higher, the LUT generates (cools) the T(a) signal and maintains the temperature of the heat exchanger at 41–43 °C. If the T(dif) is maintained at 41–43 °C, the LUT generates a T(x) signal to stop the system performance. At this time, the TC operation performance and T(dif) generation process for comparing and determining the signal of T(o) and T(ref) for drugs leaking out of the abdominal cavity is very important. It was observed that the faster the response signal, the lower the comparison and judgment error was; therefore, the response signal was confirmed to be 0.209 μs. The proposed method can guarantee rapid/accurate/safe treatment and automatically induce temperature adjustment; thus, it could be applied to the field of surgery.
format Online
Article
Text
id pubmed-10422214
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104222142023-08-13 The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery Yoon, Kicheol Lee, Sangyun Lee, Tae-Hyeon Kim, Kwang Gi Sensors (Basel) Article After surgery for ovarian cancer or colorectal cancer, residual tumors are left around. A practical way to treat residual tumors is to destroy them with heat by injecting high-temperature drugs into the abdominal cavity. The injected medicinal substances are induced to flow out of the abdominal cavity; then, the spilled drug flows back into the abdominal cavity through feedback. During this process, the heat starts to decrease; thus, the treatment performance reduces. To overcome this problem, this study compares and assesses the temperature needed to maintain the heat for treatment and transmits a command signal to the heat exchanger through a look-up table (LUT). When the temperature decreases during the circulation of medications leaking out of the abdominal cavity, the LUT transmits a control signal (T(p)) to the heat exchanger, which increases or vice versa. However, if the temperature (T(o)) is within the treatment range, the LUT sends a T(s) signal to the heat exchanger. This principle generates a pulse signal for the temperature difference (T(dif)) in TC by comparing and determining the temperature (T(o)) of the substance flowing out of the abdominal cavity with the reference temperature (T(ref)) through the temperature comparator (TC). At this time, if the signal is 41 °C or less, the LUT generates (heats) a T(p) signal so that the temperature of the heat exchanger can be maintained in the range of 41 °C to 43 °C. If the T(dif) is 44 °C or higher, the LUT generates (cools) the T(a) signal and maintains the temperature of the heat exchanger at 41–43 °C. If the T(dif) is maintained at 41–43 °C, the LUT generates a T(x) signal to stop the system performance. At this time, the TC operation performance and T(dif) generation process for comparing and determining the signal of T(o) and T(ref) for drugs leaking out of the abdominal cavity is very important. It was observed that the faster the response signal, the lower the comparison and judgment error was; therefore, the response signal was confirmed to be 0.209 μs. The proposed method can guarantee rapid/accurate/safe treatment and automatically induce temperature adjustment; thus, it could be applied to the field of surgery. MDPI 2023-07-27 /pmc/articles/PMC10422214/ /pubmed/37571507 http://dx.doi.org/10.3390/s23156722 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yoon, Kicheol
Lee, Sangyun
Lee, Tae-Hyeon
Kim, Kwang Gi
The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery
title The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery
title_full The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery
title_fullStr The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery
title_full_unstemmed The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery
title_short The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery
title_sort design of an automatic temperature compensation system through smart heat comparison/judgment and control for stable thermal treatment in hyperthermic intraperitoneal chemotherapy (hipec) surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422214/
https://www.ncbi.nlm.nih.gov/pubmed/37571507
http://dx.doi.org/10.3390/s23156722
work_keys_str_mv AT yoonkicheol thedesignofanautomatictemperaturecompensationsystemthroughsmartheatcomparisonjudgmentandcontrolforstablethermaltreatmentinhyperthermicintraperitonealchemotherapyhipecsurgery
AT leesangyun thedesignofanautomatictemperaturecompensationsystemthroughsmartheatcomparisonjudgmentandcontrolforstablethermaltreatmentinhyperthermicintraperitonealchemotherapyhipecsurgery
AT leetaehyeon thedesignofanautomatictemperaturecompensationsystemthroughsmartheatcomparisonjudgmentandcontrolforstablethermaltreatmentinhyperthermicintraperitonealchemotherapyhipecsurgery
AT kimkwanggi thedesignofanautomatictemperaturecompensationsystemthroughsmartheatcomparisonjudgmentandcontrolforstablethermaltreatmentinhyperthermicintraperitonealchemotherapyhipecsurgery
AT yoonkicheol designofanautomatictemperaturecompensationsystemthroughsmartheatcomparisonjudgmentandcontrolforstablethermaltreatmentinhyperthermicintraperitonealchemotherapyhipecsurgery
AT leesangyun designofanautomatictemperaturecompensationsystemthroughsmartheatcomparisonjudgmentandcontrolforstablethermaltreatmentinhyperthermicintraperitonealchemotherapyhipecsurgery
AT leetaehyeon designofanautomatictemperaturecompensationsystemthroughsmartheatcomparisonjudgmentandcontrolforstablethermaltreatmentinhyperthermicintraperitonealchemotherapyhipecsurgery
AT kimkwanggi designofanautomatictemperaturecompensationsystemthroughsmartheatcomparisonjudgmentandcontrolforstablethermaltreatmentinhyperthermicintraperitonealchemotherapyhipecsurgery