Cargando…

Towards Monitoring and Identification of Red Palm Weevil Gender Using Microwave CSRR-Loaded TL Sensors

This paper presents for the first time the design of a microwave sensing setup for the potential monitoring and identification of red palm weevil (RPW) gender type. The microwave sensor consists of a planar two-port transmission line (TL) with a single complementary split-ring resonant (CSRR) inclus...

Descripción completa

Detalles Bibliográficos
Autor principal: Bait-Suwailam, Mohammed M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422271/
https://www.ncbi.nlm.nih.gov/pubmed/37571581
http://dx.doi.org/10.3390/s23156798
_version_ 1785089166665580544
author Bait-Suwailam, Mohammed M.
author_facet Bait-Suwailam, Mohammed M.
author_sort Bait-Suwailam, Mohammed M.
collection PubMed
description This paper presents for the first time the design of a microwave sensing setup for the potential monitoring and identification of red palm weevil (RPW) gender type. The microwave sensor consists of a planar two-port transmission line (TL) with a single complementary split-ring resonant (CSRR) inclusion etched from the bottom metallic layer. The CSRR sensor is placed on top of a customized non-conductive container. The microwave sensing setup was designed, numerically demonstrated, fabricated and tested experimentally. Simulated results correlate quite well with the experimental data. Moreover, the sensitivity of the CSRR sensor when in close proximity to different RPW genders was evaluated both numerically and experimentally. Based on the measured results from 15 RPW samples with different body sizes, different RPW gender types showed unique microwave signatures. A notable shift in the sensor’s resonance frequency was achieved, where on average a resonant frequency shift of 10% for adult RPWs was achieved, while a 2.4% frequency change was obtained for larvae (young) RPWs. Hence, the proposed microwave sensing setup can be adopted in field trials to examine and differentiate between various RPW genders at various developmental stages.
format Online
Article
Text
id pubmed-10422271
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104222712023-08-13 Towards Monitoring and Identification of Red Palm Weevil Gender Using Microwave CSRR-Loaded TL Sensors Bait-Suwailam, Mohammed M. Sensors (Basel) Article This paper presents for the first time the design of a microwave sensing setup for the potential monitoring and identification of red palm weevil (RPW) gender type. The microwave sensor consists of a planar two-port transmission line (TL) with a single complementary split-ring resonant (CSRR) inclusion etched from the bottom metallic layer. The CSRR sensor is placed on top of a customized non-conductive container. The microwave sensing setup was designed, numerically demonstrated, fabricated and tested experimentally. Simulated results correlate quite well with the experimental data. Moreover, the sensitivity of the CSRR sensor when in close proximity to different RPW genders was evaluated both numerically and experimentally. Based on the measured results from 15 RPW samples with different body sizes, different RPW gender types showed unique microwave signatures. A notable shift in the sensor’s resonance frequency was achieved, where on average a resonant frequency shift of 10% for adult RPWs was achieved, while a 2.4% frequency change was obtained for larvae (young) RPWs. Hence, the proposed microwave sensing setup can be adopted in field trials to examine and differentiate between various RPW genders at various developmental stages. MDPI 2023-07-30 /pmc/articles/PMC10422271/ /pubmed/37571581 http://dx.doi.org/10.3390/s23156798 Text en © 2023 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bait-Suwailam, Mohammed M.
Towards Monitoring and Identification of Red Palm Weevil Gender Using Microwave CSRR-Loaded TL Sensors
title Towards Monitoring and Identification of Red Palm Weevil Gender Using Microwave CSRR-Loaded TL Sensors
title_full Towards Monitoring and Identification of Red Palm Weevil Gender Using Microwave CSRR-Loaded TL Sensors
title_fullStr Towards Monitoring and Identification of Red Palm Weevil Gender Using Microwave CSRR-Loaded TL Sensors
title_full_unstemmed Towards Monitoring and Identification of Red Palm Weevil Gender Using Microwave CSRR-Loaded TL Sensors
title_short Towards Monitoring and Identification of Red Palm Weevil Gender Using Microwave CSRR-Loaded TL Sensors
title_sort towards monitoring and identification of red palm weevil gender using microwave csrr-loaded tl sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422271/
https://www.ncbi.nlm.nih.gov/pubmed/37571581
http://dx.doi.org/10.3390/s23156798
work_keys_str_mv AT baitsuwailammohammedm towardsmonitoringandidentificationofredpalmweevilgenderusingmicrowavecsrrloadedtlsensors