An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual Synchronous Generator under Distorted Grid Voltage

The proportion of distributed generation systems in power grids is increasing, leading to the gradual emergence of weak grid characteristics. Moreover, using voltage-sourced grid-connected inverters can enhance the stability of a weak grid. However, due to the presence of background harmonics in wea...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhong, Caomao, Zhang, Zhi, Zhu, Anan, Liang, Benxin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422381/
https://www.ncbi.nlm.nih.gov/pubmed/37571640
http://dx.doi.org/10.3390/s23156857
_version_ 1785089195655561216
author Zhong, Caomao
Zhang, Zhi
Zhu, Anan
Liang, Benxin
author_facet Zhong, Caomao
Zhang, Zhi
Zhu, Anan
Liang, Benxin
author_sort Zhong, Caomao
collection PubMed
description The proportion of distributed generation systems in power grids is increasing, leading to the gradual emergence of weak grid characteristics. Moreover, using voltage-sourced grid-connected inverters can enhance the stability of a weak grid. However, due to the presence of background harmonics in weak grids, the grid voltage can cause significant distortions in the grid-connected current, which adversely affects the quality of the grid-connected current. This paper begins by briefly introducing the principle of the virtual synchronous generator (VSG). Then, the output current of the voltage source inverter is analyzed to elucidate the mechanism of harmonic current generation. Considering the distortion in the grid-connected current of the voltage source grid-connected inverter caused by background harmonics in the grid voltage, a harmonic current suppression strategy based on an adaptive virtual harmonic resistor is proposed. The proposed strategy employs a signal separation module based on multiple second-order generalized integrators connected through a cross-feedback network. This module effectively separates the fundamental and harmonic currents from the grid-connected current, extracts the amplitudes of the fundamental and harmonic currents through coordinate transformation, and adaptively adjusts the virtual harmonic resistance magnitude through the negative feedback control of the harmonic content (the ratio of the harmonic current amplitude to the fundamental current amplitude). These measures are used to enhance the quality of the grid-connected current. Additionally, the stability of the system is analyzed using the root locus of the open-loop transfer function. Finally, the effectiveness of the proposed method is validated through a combination of MATLAB/Simulink simulations and experimental results.
format Online
Article
Text
id pubmed-10422381
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104223812023-08-13 An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual Synchronous Generator under Distorted Grid Voltage Zhong, Caomao Zhang, Zhi Zhu, Anan Liang, Benxin Sensors (Basel) Article The proportion of distributed generation systems in power grids is increasing, leading to the gradual emergence of weak grid characteristics. Moreover, using voltage-sourced grid-connected inverters can enhance the stability of a weak grid. However, due to the presence of background harmonics in weak grids, the grid voltage can cause significant distortions in the grid-connected current, which adversely affects the quality of the grid-connected current. This paper begins by briefly introducing the principle of the virtual synchronous generator (VSG). Then, the output current of the voltage source inverter is analyzed to elucidate the mechanism of harmonic current generation. Considering the distortion in the grid-connected current of the voltage source grid-connected inverter caused by background harmonics in the grid voltage, a harmonic current suppression strategy based on an adaptive virtual harmonic resistor is proposed. The proposed strategy employs a signal separation module based on multiple second-order generalized integrators connected through a cross-feedback network. This module effectively separates the fundamental and harmonic currents from the grid-connected current, extracts the amplitudes of the fundamental and harmonic currents through coordinate transformation, and adaptively adjusts the virtual harmonic resistance magnitude through the negative feedback control of the harmonic content (the ratio of the harmonic current amplitude to the fundamental current amplitude). These measures are used to enhance the quality of the grid-connected current. Additionally, the stability of the system is analyzed using the root locus of the open-loop transfer function. Finally, the effectiveness of the proposed method is validated through a combination of MATLAB/Simulink simulations and experimental results. MDPI 2023-08-01 /pmc/articles/PMC10422381/ /pubmed/37571640 http://dx.doi.org/10.3390/s23156857 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhong, Caomao
Zhang, Zhi
Zhu, Anan
Liang, Benxin
An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual Synchronous Generator under Distorted Grid Voltage
title An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual Synchronous Generator under Distorted Grid Voltage
title_full An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual Synchronous Generator under Distorted Grid Voltage
title_fullStr An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual Synchronous Generator under Distorted Grid Voltage
title_full_unstemmed An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual Synchronous Generator under Distorted Grid Voltage
title_short An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual Synchronous Generator under Distorted Grid Voltage
title_sort adaptive virtual impedance method for grid-connected current quality improvement of a single-phase virtual synchronous generator under distorted grid voltage
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422381/
https://www.ncbi.nlm.nih.gov/pubmed/37571640
http://dx.doi.org/10.3390/s23156857
work_keys_str_mv AT zhongcaomao anadaptivevirtualimpedancemethodforgridconnectedcurrentqualityimprovementofasinglephasevirtualsynchronousgeneratorunderdistortedgridvoltage
AT zhangzhi anadaptivevirtualimpedancemethodforgridconnectedcurrentqualityimprovementofasinglephasevirtualsynchronousgeneratorunderdistortedgridvoltage
AT zhuanan anadaptivevirtualimpedancemethodforgridconnectedcurrentqualityimprovementofasinglephasevirtualsynchronousgeneratorunderdistortedgridvoltage
AT liangbenxin anadaptivevirtualimpedancemethodforgridconnectedcurrentqualityimprovementofasinglephasevirtualsynchronousgeneratorunderdistortedgridvoltage
AT zhongcaomao adaptivevirtualimpedancemethodforgridconnectedcurrentqualityimprovementofasinglephasevirtualsynchronousgeneratorunderdistortedgridvoltage
AT zhangzhi adaptivevirtualimpedancemethodforgridconnectedcurrentqualityimprovementofasinglephasevirtualsynchronousgeneratorunderdistortedgridvoltage
AT zhuanan adaptivevirtualimpedancemethodforgridconnectedcurrentqualityimprovementofasinglephasevirtualsynchronousgeneratorunderdistortedgridvoltage
AT liangbenxin adaptivevirtualimpedancemethodforgridconnectedcurrentqualityimprovementofasinglephasevirtualsynchronousgeneratorunderdistortedgridvoltage