Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait—A Preliminary Study

In-shoe models are required to extend the clinical application of current multisegment kinetic models of the bare foot to study the effect of foot orthoses. Work to date has only addressed marker placement for reliable kinematic analyses. The purpose of this study is to address the difficulties of r...

Descripción completa

Detalles Bibliográficos
Autores principales: Sancho-Bru, Joaquín L., Sanchis-Sales, Enrique, Rodríguez-Cervantes, Pablo J., Vergés-Salas, Carles
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422389/
https://www.ncbi.nlm.nih.gov/pubmed/37571530
http://dx.doi.org/10.3390/s23156744
_version_ 1785089197628981248
author Sancho-Bru, Joaquín L.
Sanchis-Sales, Enrique
Rodríguez-Cervantes, Pablo J.
Vergés-Salas, Carles
author_facet Sancho-Bru, Joaquín L.
Sanchis-Sales, Enrique
Rodríguez-Cervantes, Pablo J.
Vergés-Salas, Carles
author_sort Sancho-Bru, Joaquín L.
collection PubMed
description In-shoe models are required to extend the clinical application of current multisegment kinetic models of the bare foot to study the effect of foot orthoses. Work to date has only addressed marker placement for reliable kinematic analyses. The purpose of this study is to address the difficulties of recording contact forces with available sensors. Ten participants walked 5 times wearing two different types of footwear by stepping on a pressure platform (ground contact forces) while wearing in-shoe pressure sensors (foot sole contact forces). Pressure data were segmented by considering contact cells’ anteroposterior location, and were used to compute 3D moments at foot joints. The mean values and 95% confidence intervals were plotted for each device per shoe condition. The peak values and times of forces and moments were computed per participant and trial under each condition, and were compared using mixed-effect tests. Test–retest reliability was analyzed by means of intraclass correlation coefficients. The curve profiles from both devices were similar, with higher joint moments for the instrumented insoles at the metatarsophalangeal joint (~26%), which were lower at the ankle (~8%) and midtarsal (~15%) joints, although the differences were nonsignificant. Not considering frictional forces resulted in ~20% lower peaks at the ankle moments compared to previous studies, which employed force plates. The device affected both shoe conditions in the same way, which suggests the interchangeability of measuring joint moments with one or the other device. This hypothesis was reinforced by the intraclass correlation coefficients, which were higher for the peak values, although only moderate-to-good. In short, both considered alternatives have drawbacks. Only the instrumented in-soles provided direct information about foot contact forces, but it was incomplete (evidenced by the difference in ankle moments between devices). However, recording ground reaction forces offers the advantage of enabling the consideration of contact friction forces (using force plates in series, or combining a pressure platform and a force plate to estimate friction forces and torque), which are less invasive than instrumented insoles (which may affect subjects’ gait).
format Online
Article
Text
id pubmed-10422389
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104223892023-08-13 Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait—A Preliminary Study Sancho-Bru, Joaquín L. Sanchis-Sales, Enrique Rodríguez-Cervantes, Pablo J. Vergés-Salas, Carles Sensors (Basel) Article In-shoe models are required to extend the clinical application of current multisegment kinetic models of the bare foot to study the effect of foot orthoses. Work to date has only addressed marker placement for reliable kinematic analyses. The purpose of this study is to address the difficulties of recording contact forces with available sensors. Ten participants walked 5 times wearing two different types of footwear by stepping on a pressure platform (ground contact forces) while wearing in-shoe pressure sensors (foot sole contact forces). Pressure data were segmented by considering contact cells’ anteroposterior location, and were used to compute 3D moments at foot joints. The mean values and 95% confidence intervals were plotted for each device per shoe condition. The peak values and times of forces and moments were computed per participant and trial under each condition, and were compared using mixed-effect tests. Test–retest reliability was analyzed by means of intraclass correlation coefficients. The curve profiles from both devices were similar, with higher joint moments for the instrumented insoles at the metatarsophalangeal joint (~26%), which were lower at the ankle (~8%) and midtarsal (~15%) joints, although the differences were nonsignificant. Not considering frictional forces resulted in ~20% lower peaks at the ankle moments compared to previous studies, which employed force plates. The device affected both shoe conditions in the same way, which suggests the interchangeability of measuring joint moments with one or the other device. This hypothesis was reinforced by the intraclass correlation coefficients, which were higher for the peak values, although only moderate-to-good. In short, both considered alternatives have drawbacks. Only the instrumented in-soles provided direct information about foot contact forces, but it was incomplete (evidenced by the difference in ankle moments between devices). However, recording ground reaction forces offers the advantage of enabling the consideration of contact friction forces (using force plates in series, or combining a pressure platform and a force plate to estimate friction forces and torque), which are less invasive than instrumented insoles (which may affect subjects’ gait). MDPI 2023-07-28 /pmc/articles/PMC10422389/ /pubmed/37571530 http://dx.doi.org/10.3390/s23156744 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sancho-Bru, Joaquín L.
Sanchis-Sales, Enrique
Rodríguez-Cervantes, Pablo J.
Vergés-Salas, Carles
Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait—A Preliminary Study
title Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait—A Preliminary Study
title_full Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait—A Preliminary Study
title_fullStr Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait—A Preliminary Study
title_full_unstemmed Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait—A Preliminary Study
title_short Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait—A Preliminary Study
title_sort foot sole contact forces vs. ground contact forces to obtain foot joint moments for in-shoe gait—a preliminary study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422389/
https://www.ncbi.nlm.nih.gov/pubmed/37571530
http://dx.doi.org/10.3390/s23156744
work_keys_str_mv AT sanchobrujoaquinl footsolecontactforcesvsgroundcontactforcestoobtainfootjointmomentsforinshoegaitapreliminarystudy
AT sanchissalesenrique footsolecontactforcesvsgroundcontactforcestoobtainfootjointmomentsforinshoegaitapreliminarystudy
AT rodriguezcervantespabloj footsolecontactforcesvsgroundcontactforcestoobtainfootjointmomentsforinshoegaitapreliminarystudy
AT vergessalascarles footsolecontactforcesvsgroundcontactforcestoobtainfootjointmomentsforinshoegaitapreliminarystudy