Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty?
PURPOSE: Postoperative limb length discrepancy (LLD) is a common complication of total hip arthroplasty, and several methods exist to prevent LLD, but each has its benefits and drawbacks. The study investigates the application of intraoperative lower limb length measurement in preventing postoperati...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10423409/ https://www.ncbi.nlm.nih.gov/pubmed/37573304 http://dx.doi.org/10.1186/s12891-023-06774-3 |
_version_ | 1785089443491741696 |
---|---|
author | Wu, Junzhe Zhuang, Xunrong Lin, Chaohui He, Lijiang Zhang, Rongmou |
author_facet | Wu, Junzhe Zhuang, Xunrong Lin, Chaohui He, Lijiang Zhang, Rongmou |
author_sort | Wu, Junzhe |
collection | PubMed |
description | PURPOSE: Postoperative limb length discrepancy (LLD) is a common complication of total hip arthroplasty, and several methods exist to prevent LLD, but each has its benefits and drawbacks. The study investigates the application of intraoperative lower limb length measurement in preventing postoperative LLD. METHODS: This study retrospectively analyzed 70 patients who underwent total hip arthroplasty from October 2018 to July 2022. The length of the lower limb on the operated side was measured intraoperatively using a sterilized paper ruler after the fitting of the trial mould and compared with the healthy side. Then the prosthesis size, depth and neck length were adjusted accordingly. RESULTS: The absolute value of postoperative LLD was found to be 6.68 ± 4.48 mm, of which 53 cases (75.7%) were less than or equal to 10 mm, while 30 patients (42.9%) were less than or equal to 5 mm. CONCLUSION: The use of intraoperative measurement is effective in reducing LLD after total hip arthroplasty. |
format | Online Article Text |
id | pubmed-10423409 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-104234092023-08-14 Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? Wu, Junzhe Zhuang, Xunrong Lin, Chaohui He, Lijiang Zhang, Rongmou BMC Musculoskelet Disord Research PURPOSE: Postoperative limb length discrepancy (LLD) is a common complication of total hip arthroplasty, and several methods exist to prevent LLD, but each has its benefits and drawbacks. The study investigates the application of intraoperative lower limb length measurement in preventing postoperative LLD. METHODS: This study retrospectively analyzed 70 patients who underwent total hip arthroplasty from October 2018 to July 2022. The length of the lower limb on the operated side was measured intraoperatively using a sterilized paper ruler after the fitting of the trial mould and compared with the healthy side. Then the prosthesis size, depth and neck length were adjusted accordingly. RESULTS: The absolute value of postoperative LLD was found to be 6.68 ± 4.48 mm, of which 53 cases (75.7%) were less than or equal to 10 mm, while 30 patients (42.9%) were less than or equal to 5 mm. CONCLUSION: The use of intraoperative measurement is effective in reducing LLD after total hip arthroplasty. BioMed Central 2023-08-12 /pmc/articles/PMC10423409/ /pubmed/37573304 http://dx.doi.org/10.1186/s12891-023-06774-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Wu, Junzhe Zhuang, Xunrong Lin, Chaohui He, Lijiang Zhang, Rongmou Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? |
title | Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? |
title_full | Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? |
title_fullStr | Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? |
title_full_unstemmed | Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? |
title_short | Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? |
title_sort | does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10423409/ https://www.ncbi.nlm.nih.gov/pubmed/37573304 http://dx.doi.org/10.1186/s12891-023-06774-3 |
work_keys_str_mv | AT wujunzhe doestheuseofintraoperativemeasurementreducelimblengthdiscrepanciesaftertotalhiparthroplasty AT zhuangxunrong doestheuseofintraoperativemeasurementreducelimblengthdiscrepanciesaftertotalhiparthroplasty AT linchaohui doestheuseofintraoperativemeasurementreducelimblengthdiscrepanciesaftertotalhiparthroplasty AT helijiang doestheuseofintraoperativemeasurementreducelimblengthdiscrepanciesaftertotalhiparthroplasty AT zhangrongmou doestheuseofintraoperativemeasurementreducelimblengthdiscrepanciesaftertotalhiparthroplasty |