Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis
This meta-analysis compares the efficacy and safety of Closed-Loop Control (CLC) to Sensor-Augmented Insulin Pump (SAP) for adolescent patients with Type 1 Diabetes Mellitus (T1DM). Eleven randomized-controlled trials were included with a total of 570 patients, from a total of 869 articles found adh...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10423718/ https://www.ncbi.nlm.nih.gov/pubmed/37574494 http://dx.doi.org/10.1038/s41598-023-40423-y |
_version_ | 1785089511872528384 |
---|---|
author | Jabari, Mosleh |
author_facet | Jabari, Mosleh |
author_sort | Jabari, Mosleh |
collection | PubMed |
description | This meta-analysis compares the efficacy and safety of Closed-Loop Control (CLC) to Sensor-Augmented Insulin Pump (SAP) for adolescent patients with Type 1 Diabetes Mellitus (T1DM). Eleven randomized-controlled trials were included with a total of 570 patients, from a total of 869 articles found adhering to PRISMA guidelines. The efficacy of the therapies were evaluated from the day, night and during physical activities monitoring of the of the mean blood glucose (BG), Time In Range (TIR), and Standard Deviation (SD) of the glucose variability. The safety measure of the therapies, was assessed from the day and night recording of the hypoglycemic and hyperglycemic events occurred. Pooled results of comparison of mean BG values for day, night and physical activities, − 4.33 [− 6.70, − 1.96] (P = 0.0003), − 16.61 [− 31.68, − 1.54] (P = 0.03) and − 8.27 [− 19.52, 2.99] (P = 0.15). The monitoring for day, night and physical activities for TIR − 13.18 [− 19.18, − 7.17] (P < 0.0001), − 15.36 [− 26.81, − 3.92] (P = 0.009) and − 7.39 [− 17.65, 2.87] (P = 0.16). The day and night results of SD of glucose variability was − 0.40 [− 0.79, − 0.00] (P = 0.05) and − 0.86 [− 2.67, 0.95] (P = 0.35). These values shows the superiority of CLC system in terms of efficacy. The safety evaluation, of the day, night and physical activities observations of average blood glucose goal hypoglycemic events − 0.54 [− 1.86, 0.79] (P = 0.43), 0.04 [− 0.20, 0.27] (P = 0.77) and 0.00 [− 0.25, 0.25] (P = 1.00) and hyperglycemic events − 0.04 [− 0.20, 0.27] (P = 0.77), − 7.11 [− 12.77, − 1.45] (P = 0.01) and − 0.00 [− 0.10, 0.10] (P = 0.97), highlights the commendable safety factor of CLC. The CLC systems can be considered as an ideal preference in the management of adolescents with type 1 diabetes to be used during a 24 h basis. |
format | Online Article Text |
id | pubmed-10423718 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-104237182023-08-15 Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis Jabari, Mosleh Sci Rep Article This meta-analysis compares the efficacy and safety of Closed-Loop Control (CLC) to Sensor-Augmented Insulin Pump (SAP) for adolescent patients with Type 1 Diabetes Mellitus (T1DM). Eleven randomized-controlled trials were included with a total of 570 patients, from a total of 869 articles found adhering to PRISMA guidelines. The efficacy of the therapies were evaluated from the day, night and during physical activities monitoring of the of the mean blood glucose (BG), Time In Range (TIR), and Standard Deviation (SD) of the glucose variability. The safety measure of the therapies, was assessed from the day and night recording of the hypoglycemic and hyperglycemic events occurred. Pooled results of comparison of mean BG values for day, night and physical activities, − 4.33 [− 6.70, − 1.96] (P = 0.0003), − 16.61 [− 31.68, − 1.54] (P = 0.03) and − 8.27 [− 19.52, 2.99] (P = 0.15). The monitoring for day, night and physical activities for TIR − 13.18 [− 19.18, − 7.17] (P < 0.0001), − 15.36 [− 26.81, − 3.92] (P = 0.009) and − 7.39 [− 17.65, 2.87] (P = 0.16). The day and night results of SD of glucose variability was − 0.40 [− 0.79, − 0.00] (P = 0.05) and − 0.86 [− 2.67, 0.95] (P = 0.35). These values shows the superiority of CLC system in terms of efficacy. The safety evaluation, of the day, night and physical activities observations of average blood glucose goal hypoglycemic events − 0.54 [− 1.86, 0.79] (P = 0.43), 0.04 [− 0.20, 0.27] (P = 0.77) and 0.00 [− 0.25, 0.25] (P = 1.00) and hyperglycemic events − 0.04 [− 0.20, 0.27] (P = 0.77), − 7.11 [− 12.77, − 1.45] (P = 0.01) and − 0.00 [− 0.10, 0.10] (P = 0.97), highlights the commendable safety factor of CLC. The CLC systems can be considered as an ideal preference in the management of adolescents with type 1 diabetes to be used during a 24 h basis. Nature Publishing Group UK 2023-08-13 /pmc/articles/PMC10423718/ /pubmed/37574494 http://dx.doi.org/10.1038/s41598-023-40423-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Jabari, Mosleh Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis |
title | Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis |
title_full | Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis |
title_fullStr | Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis |
title_full_unstemmed | Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis |
title_short | Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis |
title_sort | efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10423718/ https://www.ncbi.nlm.nih.gov/pubmed/37574494 http://dx.doi.org/10.1038/s41598-023-40423-y |
work_keys_str_mv | AT jabarimosleh efficacyandsafetyofclosedloopcontrolsystemfortypeonediabetesinadolescentsametaanalysis |