Cargando…

Slippage of an Undeployed Stent in the Left Main Artery: A Case Report Study

Advances in stent design and technology have made stent loss during percutaneous coronary interventions rare. When an undeployed stent dislodges in the left main (LM) artery during percutaneous coronary angioplasty, the risk of life-threatening procedural complications is high. We report a 50-year-o...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdelaziz, Abdelaziz Ahmed, Taleb, Ahmed Maher Abo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10424754/
https://www.ncbi.nlm.nih.gov/pubmed/37584019
http://dx.doi.org/10.4103/heartviews.heartviews_120_22
Descripción
Sumario:Advances in stent design and technology have made stent loss during percutaneous coronary interventions rare. When an undeployed stent dislodges in the left main (LM) artery during percutaneous coronary angioplasty, the risk of life-threatening procedural complications is high. We report a 50-year-old male patient, a smoker, with a history of diabetes mellitus and hypertension with typical chest pain on minimal exertion. Electrocardiogram and echo revealed ischemic changes and regional wall motion abnormality. Culotte technique was used. A new 3 mm × 48 mm stent was inserted in the LM-left circumflex (LM-LCX) followed by stenting of the LM-left anterior descending (LM-LAD) ostia with a 3.5 mm × 18 mm stent. The two balloons were rewired and kissed. Stent slippage and dislodging in the LM artery can be corrected using the culotte technique to crush the undeployed stent behind the LM-LCX and LM-LAD stents.