Cargando…

Relationship Between Suppression Scotomas and Stereoacuity in Anisometropic Amblyopia With Successfully Treated Visual Acuity

PURPOSE: The purpose of this study was to investigate the relationship among suppression scotoma size, stereoacuity, and four-prism base-out test (4ΔBOT) results in anisometropic amblyopia with successfully treated visual acuity. METHODS: We included 103 cases of anisometropic amblyopia successfully...

Descripción completa

Detalles Bibliográficos
Autores principales: Hozumi, Kenta, Yagasaki, Teiji, Yokoyama, Yoshimi, Yagasaki, Ayaka, Haga, Yayoi, Eboshita, Riho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10424799/
https://www.ncbi.nlm.nih.gov/pubmed/37561448
http://dx.doi.org/10.1167/iovs.64.11.16
Descripción
Sumario:PURPOSE: The purpose of this study was to investigate the relationship among suppression scotoma size, stereoacuity, and four-prism base-out test (4ΔBOT) results in anisometropic amblyopia with successfully treated visual acuity. METHODS: We included 103 cases of anisometropic amblyopia successfully treated for visual acuity without strabismus. Stereoacuity was measured using a Randot Stereotest. The size of the suppression scotomas was measured using a new device, the polarized four dot (P4D) test. This is a modification of the Worth 4 dot test (W4D) device. The patients were divided into three groups based on the 4ΔBOT results: normal (group A = 29 cases), subnormal (group B = 48 cases), and abnormal (group C = 26 cases) response groups. The horizontal diameter of the suppression scotomas and stereoacuity in logarithmic values with a base of 20 seconds of arc (″) were compared among the 3 groups. RESULTS: The mean age at P4D testing was 8.4 ± 2.1 years. The average horizontal diameters of the suppression scotomas were 0.35 ± 0.79Δ, 2.01 ± 0.82Δ, and 5.50 ± 2.72Δ in groups A, B, and C, respectively, showing significant differences (A versus B: P < 0.0001, A versus C: P < 0.0001, and B versus C: P < 0.0001; 1-way ANOVA). The average logarithmic stereoacuity were 1.07 (24.95″), 1.22 (38.84″), and 1.47 (82.79″) in groups A, B, and C, respectively, thereby showing significant differences between the groups (A versus B: P < 0.0001, A versus C: P < 0.0001, and B versus C: P < 0.0001; 1-way ANOVA). Stereoacuity and horizontal diameter of the suppression scotoma were strongly correlated (r = 0.732, P < 0.0001). CONCLUSIONS: The suppression scotoma size measured using P4D correlated significantly with stereoacuity and the 4ΔBOT results.